General
These are the mounting instructions for the Novy hood shown on the cover. The user manual is a separate booklet that is supplied with the hood. Carefully read these instructions before installing and commissioning the hood. A number of symbols are used in these mounting in-structions. The meanings of these symbols are given below.

Safety

Observe the following mounting and safety tips for mounting:

  •  The installation and electrical connection of the unit shall be carried out by an authorized expert.
  •  The manufacturer does not accept any responsibility for any damage resulting from faulty building in or connection.
  •  Check if all mounting materials have been supplied using the drawings on page 4.
  •  The unit is intended for household use only (preparation of food) excluding any other domestic, commercial or industrial use.
  •  Safety can only be guaranteed if the unit is connected to an earth wire in accordance with the required regulations.
  •  Do not use an extension cord for connecting to the electricity grid.
  •  Replace defective or damaged parts only with original Novy parts.

Important before mounting
Page 4 of these mounting instructions shows the mounting drawings. Observe the following mounting tips before starting the mounting activities:

  •  For easier mounting of the hood, it is recommended to do this with at least 2 persons.
  •  The housing of the unit to be mounted has the right dimensions.

INSTALLATION

  1. Make sure that the power circuit to which the unit is connected is switched off.

  2. Check that all the hood accessories are present in the packaging.

  3. Warning: pick up the hood only at the frontside to prevent glass damage of the hood.

  4. Check that all the hob parts are present in the packaging.

  5. Built-in height G≥ 760mm surface mounting: Make cut-out in bottom plate cabinet

  6. Built-in height G≥ 760mm flushing mounting: Make cut-out in bottom plate cabinet

  7. Built-in height G < 760mm

  8. When the height cabinet + worktop < 760mm, a cut-out in the bottom plate of the cabinet needs to be performed to install the cooker hood.

  9. To install the cooker hood kit 1821.400 (optional) can be used. Follow the steps described in the corresponding installation manual of the extension kit and then continue back from step 8.

  10. Measure the height left (Y1) and right (Y2) from the hob base plate to the supporting surface. Surface mount (L) = Top worktop surface. Flush mount supporting (R) = Milled edge in the worktop.

  11. Set the height (Y) with the leveling feet, and measure from the top surface of the hood to the underside of the leveling feet.

  12. Measure the height (V) from the underside of the hood to the underside of the leveling feet (needed for vertical bend).

  13. Secure the leveling feet with the wrench 17. Measure the height (Q) from the base plate to the ground position.

  14. Cut the vertical bend (1821167) to size X = V + Q.

  15. Slide the vertical bend (1821167) into the outlet piece below the hood.

  16. Make sure that the hood guides are fully inward and secure this position.

  17. Lift the hood through the worktop cut-out in the housing. Place the positioning guides (1821135) between the worktop cut-out and the hood.

  18. Position the side and rear edge of the hood against these two guides. Set the adjusting bolts (the bolt and the lock nut 906136 + 906173) to the center of its range to make fine adjustments of the hood possible later. Slide the hood guides fully against the side wall of the housing. Slide the mounting brackets (1821088 + 1821089) between the bolt and the lock nut (906136 + 906173) nut of the guide until they are in the center of the groove. Secure this position with the screws supplied (1821153). Perform this action on both the left and right.

  19. 90-100 cm Cabinet: Secure the position of the guides.

  20. 120 cm Cabinet: Move the screws to the outermost position and secure the position of the guides. Level the hood at both the left and right by moving it forwards or backward at the bottom. Use a short spirit level (≤ 30cm) and place this on the marked places. Secure the position of both leveling feet in the housing with the plates (1821043) and screws (1821153).

  21. Adjust the position as necessary with the adjusting bolts (the bolt and the lock nut 906136 + 906173) on the guides.

  22. The positioning guides (1821135) must be positioned with minimal clearance between the worktop cut-out and the hood. Remove the positioning guides (1821135).

  23. Check the height of the cooker hood with a ruler, it MUST be leveled with the worktop (A surface) or milled edge (B Flush mounted).
    Adjust if necessary with the leveling feet. Apply the waterproof tape (Step 4) on the bottom of the induction hob.

  24. Place the induction hob on the hood. Make sure the edge of the cut-out in the induction hob glass is aligned with the side profiles of the tower. Carefully place the upper glass (1821158) with the pins in the cut-outs provided in the hood.

  25. Surface mounting: Adjust the position of the induction hob until the spacing around the tower top glass and cut-out is even.

  26. Flushing mounting: Adjust the position (front, back, left, and right) of the cooker hood until the spacing around the tower top glass and cut-out is even. (STEPS 18, 21)

  27. Secure the position of the hob on the hood with the four screws (1821254).

  28. Adjust as necessary the height of the tower with respect to the top of the hob.

  29. Turn the bolt with a wrench 10 counter-clockwise to raise the tower and clockwise to lower it.

  30. Connect first the hob cable connector to the hood.

  31. Hood: connect the plug to the mains supply. Hob: connect the hob’s power cable according to the relevant connection diagram Recirculation built-in box option: connect the in-built box to the hood outlet, if necessary, use optional fittings.

  32. Outlet with wall outlet grille option: use optional fittings to make the connection with the duct work possible.

  33. Switch the unit power supply circuit on.

  34. The tower now moves to its highest position (30 cm).

  35. Remove the safety sticker from the tower. The 4 LEDs on the controller flash.

  36. Slide both lower collection trays into the hood with the short side (K) facing forward (1821039).

  37. Place the collection security (1821159) in the hood and positioned it against the center of the tower.

  38. Slide both upper collection trays (1821107) into the hood.

  39. Place both grease filters (1821020 + 1821134) in the hood on the fall protection.

  40. Verify the correct placement of the grease filters using the positioning tab.

  41. Place the front glass (1821126) on the hood tower.

  42. Position the tabs of the glass in the cut-out in the tower and tilt the glass toward the magnets until the glass snaps into place.

  43. Press the knob to re-initialize the tower. The tower now moves to the closed position. Recirculation: The device is set in recirculation mode by default.

  44. Duct out: set the device in duct out mode by press-acknowledge the setting.

  45. Repeat these actions for recirculation mode, the led will be on for 3 seconds.

  46. OPTIONAL: Installation I/O module (990036) Remove the cover from the connection connector.

  47. Plug in the I/O module connection cable into the connector. (See manual 990036 I/O module)