GENERAL INFORMATION
General
These are the mounting instructions for the Novy hood shown on the cover. The
user manual is a separate booklet that is supplied with the hood. Carefully
read these instructions before installing and commissioning the hood.
A number of symbols are used in these mounting instructions. The meanings of
these symbols are given
below
Symbol | Meaning | Action |
---|---|---|
Indication | Explanation of an indication on the hood. | |
Warning | This symbol indicates an important tip or a dangerous situation |
Safety
Observe the following mounting and safety tips for mounting:
- The installation and electrical connection of the unit shall be carried out by an authorised expert.
- The manufacturer does not accept any responsibility for any damage resulting from faulty building in or connection.
- Check if all mounting materials have been supplied using the drawings on page 4.
- The unit is intended for household use only (preparation of food) excluding any other domestic, commercial or industrial use.
- Safety can only be guaranteed if the unit is connected to an earth wire in accordance with the required regulations.
- Do not use an extension cord for connecting to the electricity grid.
- Replace defective or damaged parts only with original Novy parts.
Important before mounting
Page 4 of these mounting instructions shows the mounting drawings. Observe
the following mountingtips before starting the mounting activities:
- For easier mounting of the hood it is recommended to do this with at least 2 persons.
- The housing of the unit to be mounted has the right dimensions.
INSTALLATION
① Make sure that the power circuit to which the unit is connected is switched off.
② Check that all the hood accessories are present in the packaging.
③ Warning: pick up the hood only at the frontside to prevent glass damage of the hood.
④ Check that all the hob parts are present in the packaging.
⑤ a Built-in height G≥ 760mm surface mounting: Make cut-out in bottom
plate cabinet
⑤ b Built-in height G≥ 760mm flushline mounting: Make cut-out in bottom
plate cabinet
⑥ Built-in height G < 760mm
When height cabinet + worktop < 760mm, a cut-out in the bottom plate of the
cabinet needs to be performed to install the cooker hood. To install the
cooker hood kit 1821.400 can be used. Follow the steps described in the
corresponding installation manualof the extension kit and then continue back
from step 8.
⑦ Measure the height left (Y1) and right (Y2) from the hob base plate to the
supporting surface.Surface mount (L) = Top worktop surface. Flush mount
supporting (R) = Milled edge in worktop.
⑧ Set the height (Y) with the levelling feet, measure from the top surface of
the hood to the underside of the levelling feet.Measure the height (V) from
the underside of the hood to the underside of the levelling feet (needed for
vertical bend).
⑨ Secure the levelling feet with the wrench 17
⑩ Measure the height (Q) from the base plate to the ground position.
⑪ Cut the vertical bend to size X = V + Q.
⑫ Slide the vertical bend into the outlet piece below the hood.
⑬ Make sure that the hood guides are fully inward and secure this position.
⑭Lift the hood through the work top cut-out in the housing.
Warning: hold the hood only at the outside to prevent the glass breaking.
Warning: this activity is best done by 2 people
⑮ Place the positioning guides (1821135) between the worktop cut-out and the hood. Position the side and rear edge of the hood against these two guides.
⑯ Set the bolt to the centre of its range to make fine adjustment of the hood possible later.
⑰ Slide the hood guides fully against the side wall of the housing.Slide the
mounting brackets between the bolt and the lock nut of the guide until they
are in the centre of the groove.Secure this position with the screws supplied
No. 1821153. Perform this action on both the left and right.
⑱ a 90-100 cm Cabinet: Secure the position of the guides
⑱ b 120 cm Cabinet: Move the screws to the outermost position and secure the position of the guides.
⑲ Level the hood at both the left and right by moving it forwards or backwards
at the bottom. Use a short spirit level (≤ 30cm) and place this on the marked
places.
⑳ on the marked places. 20 Secure the position of both levelling feet in the
housing with the plates n° 1821043 and screws n° 1821153.
㉑ Adjust the position as necessary with the adjusting bolts on the guides. The
positioning guides must be positioned with minimal clearance between the
worktop cut-out and the hood.
㉒ Remove the positioning guides.
㉓ Check the height of the cooker hood with a ruler, it MUST be levelled
with the worktop (A surface) or milled edge ( B Flush mounted).
㉔ Apply the waterproof tape on the bottom of the induction hob.
Warning: Do not apply sealant between the bottom side of the hob and the
worktop.
㉕ Place the induction hob on the hood. Make sure the edge of the cut-out in
the induction hob glass is aligned with the side profiles of the tower.
Carefully place the upper glass with the pins in the cut-outs provided in the
hood.
**Warning: perform the above action carefully to prevent glass damage and
scratches.
㉖ Surface mounting: Adjust the position of the induction hob until the
spacing around the tower top glass and cut-out is even.
Flushline mounting: Adjust the position (front, back, left and right) of
the cooker hood until the spacing around the tower top glass and cut-out is
even. (STEP 18, 21)
㉗ Secure the position of the hob on the hood with the four screws n° 1821254.
Warning: Tighten these bolts only finger tight, do not use a hand-held
screwdriver.
㉘㉙ Adjust as necessary the height of the tower with respect to the top of the
hob. Turn the bolt with a wrench 10 counter-clockwise to raisethe tower and
clockwise to lower it.
㉚ Connect first the hob cable connector to the hood.
Warning: Make sure to connect the connector in the correct direction.
Connect then the hob power supply connector to the hole.
㉛ Hood: connect the plug to the mains supply. Hob:** connect the hob’s
power cable according to the relevant connection diagram
㉜ a Recirculation built-in box option : connect the in-built box to the hood outlet, if necessary, use optional fittings.
㉜ b Outlet with wall outlet grille option: use optional fittings to make
the connection with the duct work possible.
㉝ Switch the unit power supply circuit on
㉞ Keep the knob pressed for 3 seconds
If the 4 LEDs on the control flash directly, the safety system of the tower
is activated.You can manually turn the tower up using a flat screwdriver.
Carefully remove the top glass from thetower and place the screwdriver in the
provided recess of the spindle in the centreof the tower. Now turn the tower
fully up until the safety switch as in step 36 is visible.
㉟ The tower now moves to its highest position (30 cm).
㊱ Remove the safety sticker from the tower. The 4 LEDs on the controller flash.
㊲ Slide both lower collection trays into the hood with the short side (K) facing forward n° 1821039
㊳ Place the collection security n° 1821159 in the hood and positioned against the center of the tower.
㊴ Slide both upper collection trays n° 1821107 into the hood.
㊵ Place both grease filters in the hood on the fall protection.
㊶ Verify the correct placement of the grease filters using the positioning tab.
㊷ Place the front glass on the hood tower. Position the tabs of the glass in the cut-out in the tower and tilt the glass toward the magnets until the glass snaps into place.
㊸ Press the knob to re-initialise the tower.
㊹ The tower now moves to the closed position.
㊺ Recirculation: Device is set in recirculation mode by default. Duct out:
set device in duct out mode by pressing the key combination “+” and “ ” and
during 3 seconds. The led next to will blink 3x to acknowledge the setting.
Repeat these actions for recirculation mode, the led will be on for 3 seconds.
㊻ OPTIONAL: Installation I/O module n° 990036 Remove the cover from the
connection connector.
㊼ Plug in the I/O module connection cable into the connector. (See manual 990036 I/O module)
Novy nv reserves the right at any time and without reservation to change the structure and the prices of its products.
NOVY nv Noordlaan 6 B – 8520 KUURNE Tel. 056/36.51.00 Fax 056/35.32.51 E-mail: novy@novy.be http://www.novy.be
France: Tél: 0320.940662
Deutschland und Österreich: Tel: +49 (0)511.54.20.771
Nederland: Tel.: +31 (0)88-0119110
United Kingdom: +44 (0)207 866 2493
España: Tel.: +34 938 700 895
Italia: Tel.: +39 039.20.57.501
References