Q-TRAN QOMS 60W-750W AC Power Supply Installation Guide
- June 10, 2024
- Q-TRAN
Table of Contents
INSTALLATION QOMS/QOMD
QOMS 60W-750W
1 CONTROL ZONE
-
Front View
-
Bottom View
-
PRIMARY
Line Voltage -
Land Ground
-
Land Hot
-
Land Neutral
-
Chose either tap 1 (switch) or 2 (dimmer; long primary run or low input voltage (115V or less))
-
*Must test all voltage readings with a True RMS Voltage Meter when controlled by a dimmer. Do not exceed secondary voltage!
-
SECONDARY
Low Voltage -
If 12V Taps are
12V, 13V, 14V, 15V -
*Up to 5 Sec. Breakers can be used
-
BKR COLOR 12V 24V
5 A Orange 60w 120w
10 A Red 120w 240w
12.5 A Yellow 150w 300w
15 A Yellow 180w 360w
20 A Blue 240w 480w
25 A Purple 300w 600w -
Step 1.
Connect line side or “hot” side of the low voltage connection.
Start with position # 1.
Step 2.
Connect common side to one of the low voltage terminal blocks.
-
Repeat step 1 & 2 for every new lead connection. 14. L.V. Secondary feeds go to a 85 AMP rated terminal block. Each terminal is UL listed to have the following capacity:
6 #14
4 #12
4 #10
2 #8- *For longer runs you may need to go to a higher tap & or larger wire gauge on secondary side.
QOMD 60W-300W
2 CONTROL ZONES
-
Front View
-
Bottom View
-
PRIMARY
Line Voltage -
Land Ground
-
Land Hot
-
Land Neutral
-
Chose either tap 1 (switch) or 2 (dimmer; long primary run or low input voltage (115V or less))
-
*Must test all voltage readings with a True RMS Voltage Meter when controlled by a dimmer. Do not exceed secondary voltage!
-
SECONDARY
Low Voltage -
If 12V Taps are
12V, 13V, 14V, 15V -
*Up to 5 Sec. Breakers can be used
-
BKR COLOR 12V 24V
5 A Orange 60w 120w
10 A Red 120w 240w
12.5 A Yellow 150w 300w
15 A Yellow 180w 360w
20 A Blue 240w 480w
25 A Purple 300w 600w -
Step 1.
Connect line side or “hot” side of the low voltage connection.
Start with position # 1.
Step 2.
Connect common side to one of the low voltage terminal blocks.
-
Repeat step 1 & 2 for every new lead connection. 14. L.V. Secondary feeds go to a 85 AMP rated terminal block. Each terminal is UL listed to have the following capacity:
6 #14
4 #12
4 #10
2 #8- *For longer runs you may need to go to a higher tap & or larger wire gauge on secondary side.
Wiring Diagram
120V (60Hz) – 12/24V
PRIMARY SECONDARY
120VAC 12 VAC
*( ) CONNECT TO ANY TAP**
– USE SECONDARY TERMINAL BLOCKS FOR LOAD CONNECTIONS
– DASHED LINES INDICATE ELECTRICAL CONTRACTOR WIRING
– MULTIPLE LOADS CAN BE CONNECTED TO THE SAME OR DIFFERENT TAPS, DEPENDING ON
DESIRED OUTPUT VOLTAGE, TO COMPENSATE FOR VARYING LOAD DISTANCES.
230V (50Hz) – 12/24V-
277V (60Hz) – 12/24V
PRIMARY SECONDARY
230/277VAC 12 VAC
*( )CONNECT TO ANY TAP**
– USE SECONDARY TERMINAL BLOCKS FOR LOAD CONNECTIONS
– DASHED LINES INDICATE ELECTRICAL CONTRACTOR WIRING
– MULTIPLE LOADS CAN BE CONNECTED TO THE SAME OR DIFFERENT TAPS, DEPENDING ON
DESIRED OUTPUT VOLTAGE, TO COMPENSATE FOR VARYING LOAD DISTANCES.
Selecting the Right Tap
Conclusion:
With a simple field adjustment, the contractor was able to recover his voltage
drop and light output by switching from Tap 12 to Tap 15.
A 12V Lamp Operating at 10V = 50 % Light Output!
Rating|
Excellent
| Good| Poor| Bad| Very Bad
---|---|---|---|---|---
Light Output
| | | | |
Lamp Volts|
24.0V
| 22.8V| 21.6V| 20.4V|
19.2V
Voltage Drop|
0%
| -5%| -10%| -15%|
-20%
Lamp Volts|
12.0V
| 11.4V| 10.8V| 10.2V|
9.6V
Light Output| | | | |
Rating
| Excellent| Good| Poor| Bad|
Very Bad
The Impact of Voltage Drop on Light Output
*For longer runs you may need to go to a higher tap & or larger wire gauge on secondary side.
* Use a True RMS Volt Meter when a dimmer is used.
(RMS = Root Mean Squared)
- The “line side” of the load is connected to secondary circuit breakers.
[4 AMP – 25 AMP]
Warnings
WARNING
FOR CONDUIT CONNECTION
RISK OF ELECTRIC SHOCK.
Install power unit 5 feet (1.5 m) or more from the pool or spa and 10 feet
(3.05 m) or more from a fountain. Where the power unit is installed within 10
feet (3.05 m) of a pool or spa, connect unit to GFCI protected branch circuit.
FOR POWER SUPPLY CORD CONNECTION
RISK OF ELECTRIC SHOCK.
Install power unit 5 feet (1.5 m) or more from the pool, spa, or fountain.
Where the power unit is installed (a) indoors within 10 feet (3.05 m) of a
pool, spa, or fountain or (b) outdoors, connect power unit to a receptacle
protected by a GFCI.
RISK OF FIRE. If installation requires running wire through a building structure, special wiring methods are needed. Contact a qualified electrician.
OUTDOOR CORD – connected unit shall be connected to a GFCI protected hooded flush type cover plate recepticle marked “Wet Location.
DO NOT USE EXTENSION CHORDS.
The main Secondary Wiring is intended for shallow burial – less than 6 inches (152 mm) For Supply connections use wire rated for at least 60C.
- To order additional lengths of wire for connection in the secondary, contact your local distributor or Q-Tran at 203-367-8777 and inquire about Q-Wire.
LISTED 5F78
LOW VOLTAGE LIGHTING POWER SUPPLY CENTER
- LANDSCAPE LIGHTING POWER UNIT
- SUITABLE FOR WET LOCATION
- SUITABLE FOR INDOOR/OUTDOOR USE
- UL 1838 & 2108 LISTED
- ISOLATION TOROIDAL TRANSFORMER
- USE DIMMERS RATED FOR MAGNETIC LOW VOLTAGE LOADS
- 50/60 CYCLE
- MADE IN THE U.S.A.
For model series:
QOM-60, QOM-100, QOM-150, QOM-300, QOM-500, QOM-600, QOM-750, QOM-2X150, QOM- 2X300 and QOM-150/300, all field installed conductors, both primary and secondary, shall have insulation suitable for the highest voltage potential of the equipment.
WIRE TYPE
| PRI. WIRE COLOR
---|---
HOT
NEU (TAP 1)
NEU (TAP 2)
GROUND|
BLACK
RED
ORANGE
GREEN
BREAKER
| MINIMUM AWG| 12V
---|---|---
5A
10A
15A
20A
25A| 14
14
14
12
10|
60W
120W
180W
240W
300W
| QOM| |
|
|
|
---|---|---|---|---|---|---
|
Model
| Input Voltage
(V)| Input Current
(A)| Frequency| Nominal Output Voltage
(VDC)|
Max Output Wattage
(W)
| QOM-60
QOM-60X2
QOM-60/100
QOM-60/150
QOM-60/300
QOM-100
QOM-100X2
QOM-100/150
QOM-100/300
QOM-150
QOM-150X2
QOM-150/300
QOM-300
QOM-300X2
QOM-500
QOM-600
QOM-750| 120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277| .56 / .25
1.12 / .49
1.48 / .64
1.93 / .84
3.28 / 1.42
.92 / .40
1.84 / .80
2.29 / .99
3.64 / 1.58
1.37 / .59
2.74 / 1.19
4.09 / 1.77
2.72 / 1.18
5.44 / 2.36
4.48 / 1.94
5.32 / 2.30
6.58 / 2.85| 50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60| 12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24| 60
60X2
60/100
60/150
60/300
100
100X2
100/150
100/300
150
150X2
150/300
300
300X2
500
600
750
CAUTION: USE ONLY WITH MAXIMUM OUTPUT LOAD PER ABOVE TABLE. This product must
be installed in accordance with the applicable installation code by a person
familiar with the construction and operation of the product and the hazards
involved.
- SUITABLE FOR USE WITH SUBMERSIBLE LUMINAIRES OR SUBMERSIBLE PUMPS
- SUITABLE FOR WET LOCATIONS
- WALL MOUNT ONLY
- FOR SUPPLY CONNECTIONS USE WIRE RATED FOR AT LEAST 60 C.
- SUITABLE FOR INDOOR OR OUTDOOR USE
- SUITABLE FOR MOUNTING WITHIN 1.2m (4 ft.) OF THE GROUND
- ISOLATION TOROIDAL TRANSFORMER
- DIMMER, IF USED, MUST BE A MAGNETIC LOW-VOLTAGE DIMMER.
- 50/60 CYCLE A.C. ONLY
- MADE IN THE U.S.A.
- KEEP ENCLOSURE COVER CLOSED
- READ INSTALLATION INSTRUCTIONS BEFORE WIRING
LOW VOLTAGE LUMINAIRE POWER SUPPLY CENTER
QOM Series tested to:
UL-2108, UL-1838
CSA C22.2 NO. 250.0-08
CSA C22.2 NO. 250.7-07
CLASS:
120V
3425 01
CLASS:
120V/277V
3425 81
3425 15
3425 95
WARNING: RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED. CONSULT A QUALIFIED ELECTRICIAN.
© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com
Specification subject to change. Rev-05-23-23