Roth Touchline SL Plus Room Thermostat Instruction Manual

June 10, 2024
Roth

Roth Touchline SL Plus Room Thermostat

Roth Touchline SL Plus Room Thermostat product

Product Information

The product is a thermostat that can be used for controlling underfloor heating. It has a floor sensor that can be connected to the thermostat for better temperature control. The thermostat comes with a backplate and screws for mounting on the wall. The display on the controller shows the current temperature, pre-set temperature, battery level, WiFi signal strength, and heating/cooling mode.

Product Usage Instructions

  1. To separate the front and back of the floor sensor, insert the tip of a straight-edged screwdriver into the slot between them and twist.
  2. If you have a floor sensor (not included), you can connect it to the thermostat. Carefully push the wires into the clamp and screw them on. The sensor must be pulled into the draw pipe and the sensor end placed just below the upper floor covering, in the middle between the underfloor heating pipes.
  3. Mount the backplate on the wall using the included screws and slide the thermostat onto it.
  4. To operate/set up the floor sensor, use the display on the controller. You can set it up as either Floor protection (standard) or Comfort (minimum floor temperature).
  5. When using the floor sensor as Floor protection, it will stop heating if the temperature goes above the set maximum temperature.
    Below this temperature, the room sensor has priority. When using it in Comfort mode, the room sensor will have priority between minimum and maximum settings. Outside this range, the floor sensor has priority.

Assmebly

  1. Insert the tip of a straight-edged screwdriver into the slot between the front and the back and twist the parts apart.

  2. Insert batteries (included), be aware of +/- polarity.Roth Touchline SL Plus Room Thermostat 2

  3. It is possible to connect a floor sensor to the thermostat (floor sensor not included). Carefully push the wires into the clamp and screw them on. The sensor must be pulled into the draw pipe and the sensor end placed just below the upper floor covering, in the middle between the underfloor heating pipes.Roth Touchline SL Plus Room Thermostat 3

  4. Mount backplate on the wall (screws are incl.) thermostat slides onto back plate.Roth Touchline SL Plus Room Thermostat 4

  5. The thermostat can be connected to all Controllers in the Roth Touchline® SL series. Pairing/registering is made the same way on all Controllers using the same buttons. On the pictures the panel of the Roth Touchline® SL Controller, master is shown.Roth Touchline SL Plus Room Thermostat 5

  6. Pairing/registering the thermostat to a zone (channel). All connections must be made to the Controller (pump, actuators and optionally potential free relay) before start-up. Please see controller manual for details. Attention! Do not press the buttons on the front of the thermostat whilst pushing the pairing button on the rear (see picture 11).Roth Touchline SL Plus Room Thermostat 6

  7. Once the thermostat is connected to the Zone/Channel, the overview shows: – Temperatures on the thermostat (setpoint 22,0°C, actual 25,0°C) , battery (99%), signal strenght (appears with 4 lines, there must be a minimum of 1 line during installation) and mode of operation (CON = continously). For more info on the display, see controller manual. Repeat registration for other thermostats, by choosing one of the other zones (2 to 8) until required number of thermostas are connected.
    Attention! If a thermostat is paired to the wrong zone, do not delete the thermostat. Pair the thermostat to the correct/new zone and the old pairing will be deleted.

  8. If the thermostat has a floor sensor connected, this must also be paired/registered as shown below (picture 21, must be two quick presses).Roth Touchline SL Plus Room Thermostat 7

  9. In theoverview you can see both the thermostat (setpoint 22,0°C, actual 25,0°C) and the actual floor temperature (21,0°C). Repeat this for all other zones/channels (2 to 8) with a floor sensor.Roth Touchline SL Plus Room Thermostat 8

  10. Operation/setting of the floor sensor is carried out on the display of the Controller. Floorsensor operation can be set up as either “Floor protection” (standard) or “Comfort” (min. Floor temp.).

  11. Set sensor as “Floor protection”. Choose operation mode and choose “Floor protection”.Roth Touchline SL Plus Room Thermostat 9

  12. Set max. floor temperature to protect your floor. Confim with “Menu”.Roth Touchline SL Plus Room Thermostat 10

  13. Set sensor as “Comfort”.

  14. Choose operation mode and choose “Comfort”.Roth Touchline SL Plus Room Thermostat 11

  15. Set min. floor temperature for your comfort level. Confirm with “Menu”. Min. temperature is set as described above.Roth Touchline SL Plus Room Thermostat 12

Attention! Using the floor sensor as “Floor protection”, the sensor will stop heating if the temperature goes above the setmax. temperature. Below this temperature the room sensor has priority. Using the floor sensor in “Comfort” mode, the room sensor will have priority between min. and max. setting. Outside this min/max setting the floor sensor has priority.

Funtions

  • In sleepmode the current temperature is displayed. To set/change temperature press v / A buttons. Confirm by pressing Menu.

  • You can switch between temperature display and relative humidity display by briefly pressing the Exit button.

  • How to lock the buttons . Press “Menu” Select “Yes” using one of the v / A buttons and confirm by pressing “Menu” or wait 5 seconds.
    When the lock is active, the keys are locked automatically after 10 seconds of inactivity.

  • Unlock by pressing both  v / A buttons for 5 sec. The keys are available when the display does not show the lock. The lock is active until you deactivate it in the menu.Roth Touchline SL Plus Room Thermostat 15

  • The room thermostat can show calibration value. Hold down “Menu” for 3 sec. The display shows “Cal” and the calibrated temperature. The value can ONLY be changed on the control unit, under the relevant channel/zone. It can take up to 5 minutes before the calibrated temperature is displayed.

  • The room thermostat can be deleted from a control unit by pressing “Menu” for 3 sec., Release and briefly press “Menu” again.
    FAr is set to NO by default, to change this use “v / A”. At “Yes” press “Menu” or wait 5 sec and the ther-mostat is cleared from the control unit.

  • The room thermostat can display the firmware version, by pressing  “Menu” for 3 sec., Release and press twice briefly on “Menu”.

Display Parts

| DK
---|---
1| Manual mode
2| Battery level
3| Pre-set temperature
4| Button lock
5| WiFi signal strenght
6| Current temperature
7| Heating/Cooling

Roth Touchline SL Plus Room Thermostat 19

ROTH UK Ltd
1a Berkeley Business Park Wainwright Road
Worcester WR4 9FA
Phone +44 (0) 1905 453424
E-Mail enquiries@roth-uk.com
technical@roth-uk.com
orders@roth-uk.com
roth-uk.com
ROTH FINLAND OY Raaseporintie 9 (Talo 2) 10600 Tammisaari
Puh. +358 (0)19 440 330
facebook.com/RothFinland

accounts@roth-uk.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Roth User Manuals

Related Manuals