Roth Touchline® SL Room sensor Mini

Battery Instruction
Insert battery (CR2032 included) as shown on the drawing.
Battery Instruction
The sensor can be connected to all Controllers in the Touchline® SL series. Pairing/registering is made the same way on all Controllers using the same buttons. On the pictures the panel of the Touchline® SL Controller, master is shown.
Pairing button Instruction
Pairing/registering the sensor to a zone (channel). Follow step 2 to 7 and press pairing button as shown on step 8. Finish with Menu and aerthat press several times on Exit until standard view. All connections must be made to the Controller (pump, actuators and optionally potential free relay) before start- up. Please see controller manual for details.
Pairing button Instruction
Once the sensor is connected to the Zone/Channel, the overview shows: – Temperatures on the thermostat (set point 22,0°C, actual 25,0°C) , battery (99%), signal strenght (100% – must be at least 10%) and mode of operation (CON = continously). For more info on the display, see controller manual. Repeat registration for other sensors, by choosing one of the other zones (2 to 8) until required number of sensors are connected. Attention! If a sensor is paired to the wrong zone, do not delete the sensor. Pair the sensor to the correct/new zone and the old pairing will be deleted.
Mounting screw Instruction
Mount the lid and turn lightly (2 -3 mm) with a screwdriver or coin.
Room Sensor InstallationFirst apply the self-adhesive tape (included) on the sensor, then the sensor on the wall. The ventilation grooves must point downwards.  temperature setting button
Instruction
Settings for temperature and mode must be done on the controller’s display. For constant temperature settings follow the steps 13 – 19 below.
temperature setting button Instruction
If a different mode than constant temperature is wanted, for example time schedule or time limitation, then follow the below steps below 20 – 26 below. For more information about time schedules, we refer to the online manual for Roth Touchline® SL Controller – Master.

Picture 26, now shows the new set point 22,0°C and the remaining time for this temperature (01:59). When the time expires the system automatically returns to the original selected constant temperature (19°C).

QR Code
Roth Touchline® SL QR

ROTH UK Ltd
1a Berkeley Business Park
Wainwright Road
Worcester WR4 9FA
Phone +44 (0) 1905 453424
E-Mailenquiries@roth-uk.com
technical@roth-uk.com
orders@roth-uk.com
accounts@roth-uk.com
roth-uk.com

ROTH DANMARK A/S
Centervej 5 3600 Frederikssund
Tlf. +45 4738 0121
E-mail: service@roth-danmark.dk
roth-danmark.dk

ROTH SVERIGE AB
Höjdrodergatan 22 212 39 Malmö
Tel. +46 40534090
Fax +46 40534099
E-mail: service@roth-sverige.se
roth-sverige.se

ROTH NORGE AS
Billing stadsletta 19 1396 Billing stad
Tel. +47 67 57 54 00
E-mail: service@roth-norge.no
roth-norge.no
facebook.com/RothNorge

ROTH FINLAND OY
Raaseporintie 9 (Talo 2) 10600 Tammisaari
Puh. +358 (0)19 440 330
S-posti: service@roth-finland.fi
roth-finland.fi
facebook.com/RothFinland

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Roth User Manuals

Related Manuals