Product Information
The DistanceMaster LiveCam is a laser distance-measuring device that uses a 635 nm laser. It is classified as a Class 2 laser with a power output of less than 1 mW. It can measure distances from 0.2 m to 150 m and has an accuracy of approximately ±1.5 mm. The device measures in various units including meters, feet, inches, and ` “. It comes with a USB Type-C port for storage and uses three 1.2V HR03 (AAA) NiMH batteries for power. The device also features a camera with automatic 4x zoom and a digital level.
Product Usage Instructions
Before using the DistanceMaster LiveCam, read through the operating instructions and safety precautions provided in the manual.
- To use the device, insert the rechargeable batteries and turn it on using the power button.
- To take a measurement, aim the laser at the target and press the measure button once to take a single measurement or twice to take two measurements.
- The device can also be used for continuous measurements by pressing and holding the measure button.
- The device can be set to display measurements in different units by pressing the unit button.
- The reference point can be set by pressing the reference button and adjusting the device to the desired position.
- The device can be used to calculate volume measurements by taking multiple distance measurements and following the prompts on the screen.
- The device can also be used for point-to-point measurements, angle measurements, Pythagoras calculations, trapezoid calculations, and circle volume calculations by selecting the appropriate function from the menu.
- The device can be turned off by pressing and holding the power button for two seconds.
For more information on safety and additional features of the device, refer to the manual or visit the provided website.
General safety instructions
- The device must only be used in accordance with its intended purpose and within the scope of the specifications.
- The measuring tools and accessories are not toys. Keep out of reach of children.
- Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
- Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
- The device must no longer be used if one or more of its functions fail or the battery charge is weak.
- Clean and dry the device before use.
- When using the device outdoors, make sure that the weather conditions are appropriate and/or that suitable protection measures are taken.
- Note local and national safety instructions to ensure proper use of the device.
Safety instructions Using class 2 lasers
- Attention: Do not look into the direct or reflected beam.
- Do not point the laser beam towards persons.
- If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
- Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)
Safety instructions Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.
- Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
- The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
Safety instructions Dealing with RF radiation
- The measuring device is equipped with a wireless interface.
- The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
- Umarex GmbH & Co. KG hereby declares that the DistanceMaster LiveCam radio equipment complies with the essential requirements and other provisions of the European Radio Equipment Directive 2014/53/EU (RED).
The EU Declaration of Conformity can be found in its entirety at the following address: https://packd.li/ll/akk/in
Description
- Laser reception field
- Display
- Battery compartment (backside)
- Connection socket for USB charger
- Camera
- Laser outlet
KEYPAD:
- a Function menu / Timer function
- b Laser on / measure/min/max continuous measurement
- c Subtraction function/back / View saved measured values and screenshots
- d Camera function / Screenshot
- e ON / OFF / back
- f Addition function / before
- g Settings menu
DISPLAY:
- h Battery symbol
- i Digital bubble level
- j Set measuring function
- k Measurement point (reference) front / thread / rear
- Intermediate values/min/max values
- m Measurement values / Measurement results
Inserting rechargeable batteries
Open the battery compartment and insert the rechargeable batteries (3x NiMH,
type AAA) as indicated by the installation symbols. Be sure to pay attention
to polarity. The rechargeable batteries
can be charged in the device with the supplied USB charging cable.
Switch on, measure and switch off:
Settings menu:
Addition and subtraction of lengths:
min/max continuous measurement:
The LC display shows the max value, the min value, the differential value and the current value.
Area measurement:
The room perimeter is additionally shown on the LC display.
Area calculation:
Volume measurement:
Volume calculation:
Point-to-point measurement:
Angle function:
The measurement results are determined automatically by the 360° inclination
sensor.
The back of the device can be used as a reference surface for measuring
angles.
Automatic height:
Pythagoras function 1:
Pythagoras function 2:
Pythagoras function 3:
Trapezoidal function 1:
Trapezoidal function 2:
Triangular area measurement:
Circular area measurement:
The circumference is additionally shown on the LC display.
Circular volumes:
Circular area is additionally shown on the LC display.
Stake out function:
Timer function:
Camera function:
The HD camera has an automatic 4x zoom.
Memory function:
The device has 50 storage locations.
Reference point displacement:
The set tolerance is calculated directly from the result of the measurement.
Data transfer
This device has digital connectivity which allows wireless data transfer to
mobile devices such as smartphones or tablets with a wireless interface. The
system prerequisites for a digital connection are specified a
https://packd.li/ble/v2
This device can generate a wireless connection to devices that are compatible
with the wireless standard IEEE 802.15.4. The wireless standard IEEE 802.15.4
is a transfer protocol for Wireless Personal Area Networks (WPAN). The range
is set to a maximum distance of 10 m from the terminal device and greatly
depends on the ambient conditions such as the thickness and composition of
walls, sources of interference as well as the transmit / receive properties of
the terminal device.
Enable / disable Digital Connection:
The digital connection is activated as soon as the device is switched on as the wireless system is designed to use very little electricity. A mobile device can link up to the active measuring device via an app.
Application (app)
An app is required to use the digital connection You can download the app from
the corresponding stores for the specific type of terminal device:
After starting the app and activating the digital connection, a connection can be set up between a mobile device and the measuring device.If the app detects several active measuring devices, select the matching device. This measuring device can be connected automatically the next time it is switched on.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
Calibration
The measuring device must be calibrated and tested on a regular basis to
ensure it is accurate and working properly. We recommend carrying out
calibration once a year. Contact your distributor or the UMAREX-LASERLINER
service department.
Error code:
- 204: Calculation error
- 208: Overcurrent
- 220: Replace the battery
- 255: Received signal too weak
- 256: Received signal too strong
- 261: Outside the measuring range
- 500: Hardware fault
Technical Data
(Subject to technical changes without notice. 21W48)
Technical Data (Subject to technical changes without notice. 21W48)
Precision (typical)*| ± 1.5 mm
Measurement range (inside)**|
0.2 m – 150 m
Laser wavelength| 635 nm
Laser class| 2 / < 1 mW (EN 60825-1:2014/AC:2017)
Units| m / ft / inch / ‘ ‘‘
Memory| 50 storage locations
Connections| USB type C
Power supply| 3 x 1.2V HR03 (AAA) NiMH
Operating conditions
| -10°C…40°C, Max. humidity 20…85% rH,
no condensation, Max. working altitude 2000 m above sea level
Storage conditions| -20°C…70°C, Max. humidity 80% rH
Automatic switch-off| 30 sec laser / 3 min device
Dimensions (W x H x D)| 54 x 130 x 28 mm
Weight| 184 g (incl. batteries)
- measuring distance up to 10 m with strongly reflective target surface and at room temperature. The measurement deviation may increase by ± 0.2 mm/m for greater distances and under unfavourable measuring conditions such as strong sunlight or weakly reflective target surfaces.
** at max. 15,000 lux
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at: https://packd.li/ll/akk/in
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>