Laserliner AirCheck Clima Digital Hygrometer Instruction Manual

June 10, 2024
Laserliner

Laserliner AirCheck Clima Digital Hygrometer Instruction Manual
Laserliner AirCheck Clima Digital Hygrometer

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document ! must be kept in a safe place and passed on together with the device.

Product Information

The AirCheck Clima is a device that measures humidity and temperature levels in the surrounding environment. It has a measuring range of 1% to 99% relative humidity and can display both relative humidity and ambient temperature on its LC display. The device is powered by 2 x 1.5V LR03 (AAA) batteries and has a typical operating time of 1 year depending on use.

Function / Application

  • This digital hygrometer provides information on the ambient temperature and relative humidity. The device saves the minimum and maximum climate values. The user is warned of high air humidity and dryness. The room climate can be improved using the ventilation recommendation. A well-balanced room climate has a positive influence on health and comfort levels. Climate data and the time are clearly displayed. The fold-out stand/clip and integral magnets allow the device to be placed on tables, attached to objects, or fixed to metal surfaces.

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The structure of the device must not be modified in any way.
  • Do not expose the device to mechanical stress, extreme temperatures or significant vibrationces.

Safety instructions
Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.

Danger – powerful magnetic fields

  • Powerful magnetic fields can adversely affect persons with active medical implants (e.g. pacemaker) as well as electromechanical devices (e.g. magnetic cards, mechanical clocks, precision mechanics, hard disks).
  • With regard to the effect of powerful magnetic fields on persons, the applicable national stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic fields“ (occupational health and safety – electromagnetic fields) in the Federal Republic of Germany.
  • To avoid interference/disruption, always keep the implant or device a safe distance of at least 30 cm away from the magnet.

Inserting batteries

Open the battery compartment and insert battery according to the symbols. Be sure to pay attention to polarity.
Inserting batteries

The device has been optimised for use in fixed measuring locations. Please wait ! 10 minutes after changing to a measuring location with a significantly different climate.

Product Overview

Product Overview

  1. LC display
  2. LED / Humidity warning
  3. Set timer
  4. Switch MIN/MAX values
  5. Fold-out stand
  6. Wall bracket
  7. Battery compartment

LCD Display
LCD Display

  • a Time
  • b MIN/MAX values display
  • c Relative humidity in %rH
  • d Ambient temperature in °C
  • e Timer
  • f Humidity warning
  • g Acoustic alarm
  1. MIN/MAX values display
    MAX values display

  2. Reset MIN/MAX values
    Display Instructions

  3. Set timer
    Display Instructions

  4. Cancel timer
    Display Instructions

  5. Set time
    Display Instructions

  6. Set humidity warning
    Display Instructions

The humidity warning can be set in the menu as an acoustic alarm, visual alarm or a combination of the two. In the event of constantly high or low humidity levels, the alarm symbol appears on the display and a visual and/or acoustic warning is generated at certain intervals. The alarm is not emitted constantly in order to save energy and avoid disturbances.

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Store the device in a clean and dry place.

Technical data

(Subject to technical changes without notice. 21W50)

Humidity Measuring range (relative) Accuracy (absolute) Humidity (relative)| 1% … 99% 20% … 80% (± 3%) <20% und >80% (± 5%)
---|---
Ambient temperature Measuring range Accuracy| -9,9°C … 50°C ± 1°C
Power supply| 2 x 1,5V LR03 (AAA)
Operating time| 1 year (typical, depending on use optical / acoustic alarm)
Operating conditions| Max. humidity, 85% rH, no condensation, max. working altitude 2000 m above sea level
Storage conditions| -10°C … 70°C, max. humidity, 85% rH, no condensation
Dimensions (W x H x D)| 96 x 110 x 18 mm
Weight| 148 g (incl. battery)

EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
https://laserliner.com
Symbols

SERVICE

Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: +49 2932 638-333
info@laserliner.com

Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com