Roth 466210.218 Shunting Of Underfloor Heating Distributor Shunt Installation Guide
- June 10, 2024
- Roth
Table of Contents
Roth Shunt
Living full of energy
Installation Shunt
Technical data
Roth shunt, 3-way valve | HVAC no. 7466210218 |
---|---|
Max. operating temperature | 80 ºC |
Max. differential pressure | 15 – 20 kPa |
Max. operating pressure | 6 bar |
Pump | Wilo Para 15-130/6-43/SC-12 |
Regulation range | 20-60°C (+/- 5°C) |
Primary side connection | EURO ¾” external |
Union for manifold | 1” internal |
Material | Brass CW614 |
Gasket | EPDM |
Medium | Water containing up to 50% glycol |
Electrical connection | 230V with earthing |
The shunt is mounted directly on the manifold by tightening the two 1” unions. Remember to use the gaskets supplied.
The shunt is mounted on the left, but it can be reversed by undoing all unions and rotating the pump.
Mount the thermostat on the supply valve and the sensor in the sensor pocket.
Set the thermostat to the preferred supply temperature.
Lock the thermostat to an appropriate regulation range by pressing the white
locking catches on the sensor ele ment. See the scale in Figure 4.
Venting and flushing the installation of air must be done one circuit at the time. Connect the filling hose to the upper manifold valve and the discharge hose from the lower manifold valve and flush to the drain. Refill the installation to desired pressure when all air has been removed.
The pump is set to I, II or III depending on the size of the system and heat loss in the building.
Faults that may prevent the pump operating (such as blockages) are indicated
by the red LED showing.
If the fault is indicated, rectify the fault and wait for the pump to restart
automatically.
Accessories:
Control: Roth weather compensation
HVAC no. 7466210827
ROTH UK Ltd
1a Berkeley Business Park
Wainwright Road
Worcester WR4 9FA
Phone +44 (0) 1905 453424
E-Mail enquiries@roth-uk.com
technical@roth-uk.com
orders@roth-uk.com
accounts@roth-uk.com
roth-uk.com
ROTH DANMARK A/S
Centervej 5
3600 Frederikssund
Tlf. +45 4738 0121
E-mail: service@roth-danmark.dk
roth-danmark.dk| ROTH SVERIGE AB
Höjdrodergatan 22
212 39 Malmö
Tel. +46 40534090
Fax +46 40534099
E-mail: service@roth-sverige.se
roth-sverige.se
---|---
ROTH NORGE AS
Billingstadsletta 19
1396 Billingstad
Tel. +47 67 57 54 00
E-mail: service@roth-norge.no
roth-norge.no
facebook.com/RothNorge| ROTH FINLAND OY
Raaseporintie 9 (Talo 2)
10600 Tammisaari
Puh. +358 (0)19 440 330
S-posti: service@roth-finland.fi
roth-finland.fi
facebook.com/RothFinland
RN1000.218_Installation Roth 3-vejs shunt_20220706
References
- borger.dk - din indgang til det offentlige
- thisisFINLAND
- Frontpage | Norge.no
- Roth Finland
- Roth Norge
- Roth Sverige
- Roth UK
- Hej! Welcome to sweden.se – the official website of Sweden
- UK.COM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>