LUTRON Yk-80Am Metal Vane Anemometer
PRODUCT INFORMATION
Model: YK-80AM1. Features
- Metal vane probe, heavy duty & wide air velocity and temperature measurement.
- Max air velocity measurement up to 40 m/s.
- Microprocessor circuit assures maximum possible accuracy, and provides special functions and features.
- The portable anemometer provides fast, accurate
Product Specifications
General Specifications
- Display
- 51 mm x 32 mm supper large LCD display.
- Dual function meter’s display.
- Measurement m/s (meters per second), km/h (kilometers per hour), ft/min (feet/per minute), knots (nautical miles per hour), mph (mile/h, miles per hour), Temp.-, .,
- Data hold.
- Sensor
- Air velocity sensor:
- Metal diecasting structure.
- Conventional twisted vane arms and low-friction ball-bearing design.
- Temperature sensor:
- Precision thermistor.
- Circuit
- Custom one-chip microprocessor LSI circuit.
- Memory
- Records Maximum and Minimum readings with recall.
- Power off
- Manual off by push button or Auto shut off after 10 minutes (Not activated during memory record function).
- Data Output RS 232 PC serial interface.
- Overload Indication indicated by – – – -.
- Operating Meter:
- Temperature 0 to 50 (32 to 122).
- Vane Probe: 0 to 80 (32 to 176).
- Operating Max. 80% RH.
- Power Supply Heavy duty type DC 9V battery, 006P, MN1604(PP3) or equivalent.
- Power Current Approx. DC 8.3 mA.
- Weight 220 g/0.48 LB.
- Size
- Main instrument: 200 x 68 x 30 mm (7.9 x 2.7 x 1.2 inch).
- Sensor Head: Round, 72 mm Dia.
- Accessories
- Instruction manual: 1 PC.
- Metal Vane probe: 1 PC.
- Carrying case, CA-06: 1 PC.
Electrical Specifications
Air Velocity
- Measurement Range
- m/s: 0.4 – 35.0 m/s
- km/h: 1.4 – 126.0 km/h
- mph: 0.9 – 78.3 mph
- knots: 0.8 – 68.0 knots
- ft/min: 79 – 6890 ft/min
- Resolution
- m/s: 0.1 m/s
- km/h: 0.1 km/h
- mph: 0.1 mph
- knots: 0.1 knots
- ft/min: 1 ft/min
- Accuracy
- m/s, km/h, knots: 2% + 1d
- mph: 2% + 20ft/min
Temperature
- Measuring Range: 0 to 60 / 32 to 140
- Resolution: 0.1 / 0.1
- Accuracy: 0.8 / 1.5 (<60)
Measuring Procedure
Air Velocity/Temperature Measurement
- Turn on the anemometer by pressing the power button.
- Select the unit for air velocity measurement by pressing the UNIT button.
- Hold the metal vane probe facing the airflow to be measured.
- Read the air velocity measurement on the display.
- To measure temperature, press the TEMP button.
- Hold the temperature sensor near the area to be measured.
- Read the temperature measurement on the display.
Data Hold, Date Record
- To hold the data, press the HOLD button.
- To release the hold, press the HOLD button again.
- To record the current measurement with date/time stamp, press the REC button.
Auto Power Off Disable
To disable the auto power-off feature, press and hold the REC button for 2
seconds. The display will show “OFF”. To enable auto power-off, repeat this
step.
RS232 PC Serial Interface
The anemometer has a RS232 PC serial interface for data output. Connect the
anemometer to a computer using a RS232 cable and use software to receive and
analyze the data.
Battery Replacement
To replace the battery, open the battery compartment cover and replace with
a new DC 9V battery, 006P, MN1604(PP3) or equivalent. Make sure to observe
correct polarity.
FEATURES
- Metal vane probe, heavy duty & wide air velocity and temperature measurement.
- Max air velocity measurement up to 40 m/s.
- Microprocessor circuit assures maximum possible accuracy and provides special functions and features.
- The portable anemometer provides fast, accurate readings, with digital readability and the convenience of a remote sensor separately.
- Multi-display units for air velocity measurement: m/s, km/h, ft/min, knots. mile/h.
- Dual temperature display unit:
- Low-friction ball vane wheels are accurate in both high & low velocity.
- Thermistor sensor for Temp. measurement, and fast response time.
- Large LCD, show the air velocity and the temperature value at the same time.
- Records Maximum and Minimum reading with recall.
- Data hold.
- Auto shut-off saves battery life.
- RS 232 PC serial interface.
- Operates from 006P DC 9V battery.
- Used durable, long-lasting components, including a strong, lightweight ABS-plastic housing case.
- Wide applications: use this anemometer to check air conditioning & heating systems, and measure air velocities, wind speeds, temperature…etc.
SPECIFICATIONS
General Specifications
Display| * 51 mm x 32 mm super large LCD display.
* Dual function meter’s display.
---|---
Measurement| m/s ( meters per second ), km/h ( kilometers per hour ), ft/min (
feet/per minute ),
knots ( nautical miles per hour ), mph ( mile/h, miles per hour ), Temp.Worms, clams.-, .,
Data hold.
Sensor Structure| Air velocity sensor :
Metal diecasting structure. Conventional twisted vane arms and low-friction ball-bearing design.
Temperature sensor :
Precision thermistor.
Circuit| Custom one-chip microprocessor LSI circuit.
Memory
Recall
| Records Maximum and Minimum
readings with recall.
Power off| Manual off by push button or Auto shut off after 10 minutes ( Not
activated during memory record function ).
Data Output| RS 232 PC serial interface.
Overload indication| Indicated by “——- “.
Operating Temperature| Meter :
0 to 50 ( 32 to 122 ).
Vane Probe :
0 to 80 ( 32 to 176 )
Operating Humidity | Max. 80% RH. |
---|---|
Power Supply | Heavy duty type DC 9V battery, |
006P, MN1604(PP3) or equvalent.
Power Current| Approx. DC 8.3 mA.
Weight| 220 g/0.48 LB.
Size| Main instrument:
200 x 68 x 30 mm ( 7.9 x 2.7 x 1.2 inch ).
Sensor Head:
Round, 72 mm Dia.
Accessories| Instruction manual…………………. 1 PC.
Metal Vane probe…………………… 1 PC.
Carrying case, CA-06………………. 1 PC.
Electrical Specifications
Air velocity
Measurement | Range | Resolution | Accuracy |
---|---|---|---|
m/s | 0.4 – 35.0 m/s | 0.1 m/s |
2 %+1d)
km/h| 1.4 – 126.0 km/h| 0.1 km/h
mph| 0.9 – 78.3 mph| 0.1 mph
knots| 0.8 – 68.0 knots| 0.1 knots
ft/min| 79 – 6890 ft/min| 1 ft/min| 2 %+20ft/min.)
Note:
m/s – meters per second km/h – kilometers per hour
ft/min – feet/per minute knots – nautical miles per hour mph – miles per hour (international knot)
Note: m/s – meters per second ft/min – feet/per minute mph – miles per
hour km/h – kilometers per hour knots – nautical miles per hour (international
knot)
Temperature
Measuring Range | 0 to 60/32 to 140 |
---|---|
Resolution | 0.1/0.1 |
Accuracy | 0.8/1.5 ( < 60 ) |
Remark: Above specifications are tested under the environment with RF Field Strength less than 3 V/M & frequency less than 30 MHz only.
FRONT PANEL DESCRIPTION
- 3-1 Display
- 3-2 Power Button 3-3 Hold Button
- 3-4 Record ( Max/Min ) Button
- 3-5 Unit button
- 3-6 button
- 3-7 RS-232 Output Terminal
- 3-8 Probe Input Socket
- 3-9 Battery Compartment/Cover 3-10 Stand
- 3-11 Vane Probe Head
- 3-12 Probe Handle
- 3-13 Probe Plug
- 3-14 Tripod fix nut
MEASURING PROCEDURE
Air velocity/Temperature measurement
- Install the ” Probe Plug ” ( 3-13, Fig. 1 ) into the ” Input Socket ” ( 3-8, Fig. 1 ).
- Power ON the meter by pressing the ” Power Button ” ( 3-2, fig. 1 ).
- Select the desired air velocity unit ( m/s, km/h, mph, knots, ft/min ) by pushing the ” unit Button ” ( 3-5, fig. 1 ).
- Select the desired temperature units by pushing the ” Button ” ( 3-6, fig. 1 ).
- Use the hand ( or tripod installation ) to hold the ” Probe Handle ” ( 3-12, Fig. 1 ), face the ” Vane Probe Head ” ( 3-11, Fig. 1 ) to the measured wind. In the same time the air velocity and the temp. value will show on the LCD display.
Measuring Consideration:
The ” ” mark on the sensor head indicates the mark need to face against the
direction of airflow.
4-2 Data Hold, Date Record
- Data Hold
- During the measurement, pushing the ” Data Hold Button ” ( 3-3, Fig. 1 ) will hold the measured value & the LCD will indicate ” HOLD ” symbol.
- Push the ” Data Hold Button ” again to release the data hold function.
- Data Record ( Max., Min. reading )
- The data record function records the maximum and minimum readings. Press the ” REC. Button ” ( 3-4, Fig. 1 ) to start the Data Record function and there will be a ” REC ” symbol on the display.
- With the ” REC ” symbol on the display : * Press the ” REC Button ” ( 3-4, Fig. 1 ) once, the ” REC Max ” symbol along with the maximum value will appear on the display.
- Note: If intend to delete the maximum value, just press ” Hold Button ” ( 3-3, Fig. 1 ) for a while, and then the display will show the ” REC ” symbol only & execute the memory function continuously.
- Press the ” REC. Button ” ( 3-4, Fig. 1 ) again, the ” REC Min ” symbol along with the minimum value will appear on the display.
- Note: If intend to delete the minimum value, just press ” Hold Button ” ( 3-3, Fig. 1 ) for a while, and then the display will show the ” REC ” symbol only & execute the memory function continuously.
- To exit the memory record function, just press the ” REC ” button for 2 seconds at least. The display will revert to the current reading.
AUTO POWER OFF DISABLE
The instrument has ” Auto Power Off ” function in order to prolong battery
life. The meter will shut off automatically if none of the buttons are pressed
in approx. 10 min.
To disable this function, Select the memory record function during the
measurement by pressing the ” REC. Button ” 3-4, Fig. 1 ).
RS232 PC SERIAL INTERFACE
The instrument has RS232 PC serial interface via a 3.5 mm terminal ( 3-7, Fig. 1 ). The data output is a 16-digit stream that can be utilized for the user’s specific application. An RS232 lead with the following connection will be required to link the instrument with the PC serial port.
Meter: (3.5 mm jack plug)
PC: (9W ‘D” Connector)The 16 digits data stream will be
displayed in the following format :
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
Each digit indicates the following status :
D0 | End Word |
---|---|
D1 & D8 | Display reading, D1 = LSD, D8 = MSD |
For example :
If the display reading is 1234, then D8 to D1 is : 00001234
D9| Decimal Point(DP), position from right to the left
0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP
D10| Polarity
0 = Positive 1 = Negative
D11 & D12| Annunciator for Display
| | m/s = 08
Km/h = 10| ft/min = 11| mile/h = 12
knot = 09| |
D13| When send the upper display data = 1
When send the lower display data = 2
D14| 4
D15| Start Word
RS232 FORMAT: 9600, N, 8, 1
BATTERY REPLACEMENT
- When the left corner of LCD display show ” it is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears.
- Slide the ” Battery Cover ” ( 3-9, Fig. 1 ) away from the instrument and remove the battery.
- Replace with 9V battery ( Alkaline or Heavy duty type ) and reinstate the cover.
- Make sure the battery cover is secured after changing the battery.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>