MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply User Manual

June 4, 2024
MEAN WELL

60W Single Output Switching Power Supply
LPV- 60 series
User Manual
MEAN WELL LPV-60 Series 60W Single Output Switching Power
Supply -

Features:

  • Constant voltage design
  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Over load / Over voltage
  • Cooling by free air convection
  • Fully encapsulated with IP67 level (Note.7)
  • Fully isolated plastic case
  • Class II power unit, no FG
  • Class 2 power unit
  • Pass LPS
  • Suitable for LED-related fixtures or appliances (such as LED Decoration or Advertisement devices)(Note. 7)
  • 100% full load burn-in test
  • Low cost, high reliability
  • 2 years warranty

http://www.meanwell.com.cn/Upload/PDF/LED_EN.pdf

SPECIFICATION

MODEL| LPV-60-5| LPV-60-12| LPV-60-15| LPV-60-24| LPV-60-36| LPV-60-48
---|---|---|---|---|---|---

OUTPUT

| DC VOLTAGE| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 8A| 5A| 4A| 2.5A| 1.67A| 1.25A
CURRENT RANGE| 0 ~ 8A| 0 ~ 5A| 0 ~ 4A| 0 ~ 2.5A| 0 ~ 1.67A| 0 ~ 1.25A
RATED POWER| 40W| 60W| 60W| 60W| 60W| 60W
RIPPLE & NOISE (max.) Note.2| 80mVp-p| 120mVp-p| 120mVp-p| 150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE TOLERANCE Note.3| ±8.0%| ±5.0%
LINE REGULATION| ±1.0%
LOAD REGULATION| ±6.0%| ±2.0%
SETUP, RISE TIME Note.6| 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC  500ms, 30ms / 115VAC at full load(for 48V)
HOLD UP TIME (Typ.)| 50ms/230VAC         16ms/115VAC at full load

INPUT

| VOLTAGE RANGE Note.4| 90 ~ 264VAC        127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 76%| 83%| 83%| 86%| 86%| 86%
AC CURRENT (Typ.)| 1.2A/115VAC 1A/230VAC
INRUSH CURRENT(Typ.)| COLD START 60A(twidth=525μs measured at 50% Speak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC

PROTECTION

| OVERLOAD| 110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after the fault condition is removed
OVERVOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 27.6 ~ 32.4V| 41.4 ~ 48.6V| 55.2 ~ 64.8V
Protection type: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, the period for 60min. each along X, Y, and Z axes

SAFETY & **EMC**

|

SAFETY STANDARDS

| UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(for LPV-60-12,LPV-60-24 only), EAC TP TC 004, IP67, IEC62368-1 , BS EN/EN62368-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020

OTHERS

| MTBF| 5188.4K hrs min.     Telcordia SR-332 (Bellcore); 732.1Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 162.542.532mm (LWH)
PACKING| 0.4Kg; 32pcs/13.8Kg/0.63CUFT
NOTE|

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation, and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered a component that will be operated in combination with the final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re- qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to an increase in the setup time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immersing in the water for over 30 minutes.
8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).
9. Products sourced from the Americas regions may not have the TUV/BIS/CCC logo. Please contact your MEAN WELL sales for more information.
10.  For any application note and IP waterproof function installation caution, please refer to our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
11.  This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply -
1

Recommend Mounting Direction

MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply
-2

Block Diagram

MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply -
3

Derating Curve

MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply -
4

Static Characteristics

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx

MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply -
SPECIFICATION

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals