Roth Minishunt Plus Wireless Regulation Installation Guide

June 10, 2024
Roth

Roth Mini shunt Plus
Installation

Roth Minishunt Plus Wireless Regulation Living full of energy

Description

Roth Mini shunt Plus is intended  for supplying and connecting small floor heating system to existing radiator heating systems. Two underfloor hes ting circuits can be connected with the dual coupling. The room tempera- ture is controlled via a thermostat with capillary sensor or a wireless room thermostat and actuator (fixed-value  temperature contra) Can be used on both 1- and 2-string systems and has a built-in temperature limit of 45°C.
Roth Mini shunt Plus:

1. Valve for thermostat or actuator 7. Flow, secondary
2. Circulation pump 8. Regulation valve for water volume
3. Air vent 9. Bypass valve for 1- or 2-string systems
4. Flow, primary 10. Analog thermometer
5. Return, primary 11 Insulation Box
6. Return, secondary
Pipe dimensions Number of loops May. pipe length
10,5 mm 1 70m
10,5 mm 2 2x70m
16 mm 1 90m
16 mm 2 2x90m
20 mm 1 120m
20 mm 2 2x120m

Secure an equal length when installing 2 loops.

Assembly requirements

  • The Roth Mini shunt Plus must be mounted in horizontal position as shown in picture 1
  • It must be ensured there is a differential pressure of Min. 15 kPa and Max. 50 kPa
  • The water temperature on the installation side should be min. 15°C higher than the underfloor circuit.
  • Always flush the installation before attaching the Roth Mini shunt Plus.

Assembly

  • Attach the Mini shunt Plus to a suitable wall. The pump will not cause  noise due to the dense shunt body.
  • Vent and perform pressure testing according to industry rules. Water filing, flushing and venting is optimized by combining  the design of the  shunt body with the air vent.
  • Set between 1- and 2-string systems see page 6.
  • Mount the thermostat or the actuator (wireless control only) on the  valve
  • Sensor or thermostat is placed approx. 1.7 m above the floor on an inner wall in a representative place.
  • Set the pump to constant pressure. Normally. a setting as shown in image 2€ will be sufficient to achieve optimal comfort with minimum noise.

Indicator lights (LEDs)
(2A)

Signal display
LED is lit up in green in normal operation
LED lights up/flashes  in case of a fault
(2B)
Display of selected control mode AP-v, AP-c and constant speed
(2C)
Display  of selected pump curve ( I, I I,  I I) within the control mode
(2D)
LED indicator combinations during the pump venting function, manual restart and key lock
No light  in LED = No power

Setting of Mini shunt for 1- or 2-string system, picture 3+ 4
(The factory setting is 2-string)

  • 2-string system 2.5 mm Allen screw must be completely at the bottom,  see picture 3.
  • L-string system, 2.5 mm Allen screw must be set in relation  to the desired  bypass water volume. Figure 4 shows the percentage of water that is  passed through the bypass screw at the various settings.

Roth Minishunt Plus Wireless Regulation - Bypass
valve, Bypass valve, turns open

Technical data

Application Underfloor heating system
Roth Mini shunt Plus with capillary sensor HVAC no. 7466210141
Roth Mini shunt Plus with basic wireless thermostat HVAC no. 7466210310
Roth Minishunt Plus with advanced wireless  thermostat and heating element

HVAC no. 7466210351
Max operating pressure| 6 bar
Max operating temperature| Max. 80°C on primary side
Max operating temperature| Max. 45°C on secondary side
Pump| Wilo PARA MS/ 6-43/ SC-12
Thread primary side| EURO 4″ EXL/MT
Thread secondary side| ELIXIR 34″ Ext./MT
Material| Brass CW614
Electrical connection| 230V, 50 Hz with earthing
Pump output| 3-45W
Antifreeze| Water mixed with max. 50%Glycol

Accessories

Roth Duo CC T Connection – 10,5 mm HVAC no. 7401974830
Roth Duo Splitter Set 4″ 12 – 20 mm HVAC no. 7046296220
Roth adapter 16 mm x 34″ EURO HVAC no. 7046217546
Roth adapter 20 mm x34* EURO HVAC no. 7046217550
Roth marigold coupler 10.5 mm x 3% EURO HVAC no. 7401974810
Roth marigold coupler 12 mm x %” EURO HVAC no. 7401974812
Roth marigold coupler 15 mm x %4 EURD HVAC no. 7401974815
Roth marigold coupler 16 mm x 4 EURD HVAC no. 7401974816*
Roth marigold coupler 17 mm x %4 EURO HVAC no. 7401974817
Roth marigold coupler 18 mm x %” EURO HVAC no. 7401974818
Roth marigold coupler 20 mm x %” EURO HVAC no. 7401974820*
Roth marigold cabinet Roth Mini shunt Plus HVAC no. 7046219540

Roth Mini shunt Plus QR
https://roth.support/minishunt

ROTH DANMARK A/S
Centervej 5
3600 Frederikssund
Tl +45 4738 0121
E-mail: servicemroth-danmark.dk
roth-danmark.dk| ROTH SVERIGE AB
Hujdrodergatan 22
212 39 Malmo
Tel. +46 40534090
Fax +46 40534099
E-mail: [email protected]
roth-sverige.se| ROTH NORGE AS
Billingstadsletta 19
1396 Billingstad
Tel. +47 67 57 54 00
E-mall: [email protected]
facebook.com/RothNorge| ROTH FINLAND OY
Sysimiehenkatu 12
10300 Karjaa
Puh. +358 (0)19 440 330
S-posti: [email protected]
facebook.com/RothFinland
---|---|---|---

ROTH UK Ltd
1a Berkeley Business Park
Wainwright Road
Worcester
WR4 9FA
Phone +44 (0) 1905 453424
E-Mail [email protected]
[email protected]
[email protected]
[email protected]
roth-uk.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Roth User Manuals

Related Manuals