Laserliner AirMonitor PURE Fine Dust Measuring Device Instruction Manual

June 10, 2024
Laserliner

Laserliner AirMonitor PURE Fine Dust Measuring
LOGO

Laserliner AirMonitor PURE Fine Dust Measuring Device

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.

Function / Application

This measuring device determines the concentration of fine particulate matter in two categories. The measured value is classified into three levels based on official threshold and target values. The colour and numerical display provides the user with information as well as a warning of concentrations of fine particulates which are hazardous to health. Other functions include information on the time, humidity and temperature.

General safety instructions

  •  The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  •  The structure of the device must not be modified in any way.
  •  Do not expose the device to mechanical stress, extreme temperatures or significant vibration
  •  Stop using the device if one or a number of its functions fails.
  •  This device is to be used in enclosed spaces only; do not expose to moisture or rain as this may result in electric shock.
  •  Use only genuine accessories. Use of inappropriate accessories will invalidate the warranty.
  •  To avoid the risk of fire, electric shock or personal injury never use extension cables as well as accessories not approved by the manufacturer in connection with the battery charger.

Safety instructions
Dealing with electromagnetic radiation

  •  The measuring device complies with the provisions and limit values for safety and electromagnetic compatibility in accordance with the Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/EU.
  •  Umarex GmbH & Co KG hereby declares that the electronic device Air Monitor PURE complies with the requirements and other conditions of the European Low Voltage Directive 2014/35/EU (LVD) and the EMC Directive 2014/30/EU.  The complete text of the EC declaration of conformity is available at the following internet address: https://laserliner.com
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.

Operation with power supply unit
The device is operated using the power supply unit provided.
Laserliner AirMonitor PURE Fine Dust Measuring 02

  1. Fine particulate matter indicator PM 2.5
  2. Fine particulate matter indicator PM 10
  3.  PM 2.5 value display
  4.  PM 10 value display
  5. Acoustic alarm OFF
  6.  Time display in 12/24 hour mode
  7. Temperature display: unit of measurement °C
  8.  Humidity displayLaserliner AirMonitor PURE Fine Dust Measuring 03
  • a Clock button for setting the time
  • b Night mode button for dimming the display at night
  • c Alarm button ON/OFF Hours button for switching between 12 and 24 hour clock modes
  • d Power supply connection

Set time

  1.  Hold down ‘Clock’ button (a) for 3 seconds. Hours display flashes.
  2. To set the minutes, press the ‘clock’ button (a).
  3.  To set hours/minutes, use the ’night mode’ (b) and ‘alarm’ (c) buttons.

Explanation PM 2.5 / PM 10
Fine particulate matter with a diameter of 2.5 microns and 10 microns are considered to be the most dangerous atmospheric pollutants. PM 10 fine particulate matter includes pollen and allergens from plants and flowers. PM 2.5 fine particulate matter includes industrial emissions which can penetrate deep into the respiratory tract due to their extremely small size, causing long-term damage to the lungs.

Fine particulate matter indicator

PM 2.5 0… < 10 μg/m3 10…<25 μg/m3 25 μg/m3
Colour green yellow red
Alarm
PM 10 0…<25 μg/m3 25…<50 μg/m3 50 μg/m3
--- --- --- ---
Colour green yellow red
Alarm ****

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Store the device in a clean and dry place. Maintenance work may only be carried out by qualified maintenance personnel. Maintenance is required if the device is damag ed in any way, for example, if the power cable or plug are damaged, there has been ingress of liquids or foreign bodies into the device, if the device has been rained on or subjected to moisture, if it is no longer functioning correctly, or has been dropped.

Technical data (Subject to technical changes without notice. Rev22W03)

Variable| Concentration of particular matter PM2.5 / PM10 Ambient temperature, Humidity
Ambient temperature Measuring range Accuracy| -9.9°C … 50°C
± 1°C
Humidity
Measuring range (relative) Accuracy (absolute) Humidity (relative)| 1% … 99%
± 3% (30% … 70%)
± 5% (0% … 30%, 70% … 100%)
Fine particulate matter
Measuring range Accuracy
Fine particulate matter sensitivity:| PM2.5:      0 … 999 µg/m³
PM10:       0 … 999 µg/m³
PM2.5:      0 … 100 μg/m³ (± 10 μg/m³), 100 … 999 μg/m³ (± 10%)
PM10:       0 … 100 μg/m³ (± 25 μg/m³), 100 … 999 μg/m³ (± 25%)
PM2.5:      300 nm … 2.5 µm
PM10:       300 nm … 10 µm
Sensor type| Particulate Matter
Power supply| 5V/DC / 1A power supply
Operating conditions| 0°C … 40°C, max. humidity, 80% rH, no condensation, max. working altitude 2000 m above sea level
Storage conditions| -10°C … 60°C, max. humidity, 80% rH, no condensation
Dimensions (W x H x D)| 90 x 91 x 33 mm
Weight| 152 g (without power supply unit)

EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: https://laserliner.com

SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals