beckett FC1250 Submersible Waterfall Pump Owner’s Manual
- June 10, 2024
- beckett
Table of Contents
beckett FC1250 Submersible Waterfall Pump
These high efficient pumps are equipped with internal software that allows them to automatically shut off if no water is present. To re-start un-plug the pump, re-submerge it and plug it back in.
Models: FC1250, FC2100, FC3550
WARNING
- The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying fountain pumps and other pond equipment. See your electrical supplies dealer for this device.
- Do not remove the grounding pin from the plug.
- Do not connect to any voltage other than shown on the pump.
- Do not pump flammable liquids.
- Do not use with water above 86º Fahrenheit (30ºC).
- Risk of electrical shock. This pump is supplied with a grounding conductor and ground attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
- Ensure that the electrical cord loops below the electrical outlet to form a “Drip Loop”. This will prevent water from running down the cord into the electrical outlet.
CAUTION-
- Always disconnect from electrical outlet before handling the pump.
- Do not let the pump run dry.
- Do not lift the pump by the power cord.
- Do not pump heated liquids.
- Operate in freshwater only.
- Operate pump completely submerged for proper cooling
ATTENTION
In order to get best results, operate pump completely submerged
MAINTENANCE
A clogged or dirty intake screen will greatly reduce performance. If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris contacting the intake screen. If less flow is desired, restrict the tubing on the discharge side. Never restrict the pump’s intake. To clean the pump, remove the volute (rotate counter clockwise) and use a small brush or stream of water to remove any debris.
IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING:
-
Check the GFCI/circuit breaker and try another outlet to ensure the pump is getting electrical power.
NOTE : always disconnect from the electrical outlet before handling the pump. -
Check the pump discharge and tubing for kinks and obstructions. Algae buildup can be flushed out with a garden hose.
-
Check the intake screen to ensure it is not clogged with debris.
-
Remove the volute to access the impeller area. Turn the impeller to ensure it is not broken or jammed.
-
If the impeller area is encrusted with minerals or corrosion, gently scrape the area clean.
-
If your pump has been idle for an extended period, it may be necessary to apply a drop of light oil to the shaft and spin the impeller by hand until it turns freely.
OVERVIEW
REPLACEMENT PARTS
MODEL | ROTOR-IMPELLER ASS’Y | O-RING | VOLUTE | SCREEN | ADAPTER |
---|---|---|---|---|---|
FC1250 | 21154 | 71728 | 11502 | 11501 | 11529 |
FC2100 | 21155 | 71728 | 11515 | 11512 | 11530 |
FC3550 | 21156 | 71736 | 11495 | 11494 | 11498 |
Steps to replace Rotor-Impeller Ass’y
- Unplug the pump, remove the screen & volute
- Use a flat screwdriver to pry out the back plate where the O-ring is located.
- Drop in new ass’y being sure to align the bottom of the shaft into the bottom bearing. It should rest on top of the O-ring
- Re-install the volute which holds this back plate in position.
Auto shut-off software guide
LIMITED WARRANTY
Each Beckett Corporation (“Beckett”) product is warranted to be free from defects in material and workmanship for the applicable Warranty Period (herein so called) set forth below. The Warranty Period for each product commences on the date of purchase by the original purchaser. The Warranty Periods are as follows:
Product Type or Name /Warranty Period
- Pump Models
- FR Series, DP800-1800, G Series, FC Series ………… 2 Years
- BK17/22 Series …………………………………. 2 Years
- Other Pump Models …………………………………..1 Year
- Pre-Formed Poly Ponds ………………………..………15 Years
- Waterfall Weir & Skimmer………………………..………. 5 Years
- Liner Material:
- 35 mil PVC……………………………20 Years
- 40 mil EPDM…………………………… 20 Years
- 20 mil PVC……………………………15 Years
- UV9/UV13 Filter…………………………….. 1 Year
- All Other Beckett Products.……………………………90 Days
APPLICATION :
The warranty covers only properly installed and maintained Beckett products and is limited to application at normal temperatures 32º F to 86º F, (0º C to 30º C) pumping fluids with a specific gravity up to 1.1 and with a pH range of 5 to 9 (freshwater). Other liquid applications and extreme temperature uses must be approved in advance by Beckett. The warranty does not apply to or cover damages or defects caused by external causes, including, but not limited to, improper or faulty installation or unauthorized modification, lightning, electrical surges, abuse, misuse or abnormal use or misapplication, including use in a manner inconsistent with the product’s intended function. The purchaser is responsible for determining the suitability of the product for its intended use. If products are damaged in transit, a claim should be filed with the carrier.
REMEDY :
If there has been a failure to conform to the warranty, Beckett will, at Beckett’s option, repair, replace or issue a credit or refund for the particular nonconforming product or part. Repair, replacement, credit or refund, at Beckett’s option, is the exclusive remedy in the event of a failure to conform to the warranty. Warranty claims must be made within 3 months after expiration of the applicable Warranty Period.
ADMINISTRATION:
Warranty claims must be made by calling Beckett Corporation, Customer Service Dept., telephone 866-466-4319, or by emailing CustomerService@BeckettUS.com. Proof of purchase is required, and a shipping and handling fee applies to all warranty replacements.
INSTALLATION , REMOVAL AND/OR SHIPPING CHARGES: The warranty does not cover any costs associated with the installation, removal or shipping of products subject to warranty claims.
DISCLAIMER AND LIMITATION
THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. TO THE FULL EXTENT PERMITTED BY LAW, BECKETT EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED, ALL SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY. BECKETT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN THIS WARRANTY. IN NO EVENT SHALL BECKETT BE LIABLE OR RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. BECKETT’S AGGREGATE LIABILITY UNDER THIS WARRANTY OR WITH RESPECT TO ANY PRODUCT COVERED HEREBY, UNDER ANY LEGAL THEORY, SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE NONCONFORMING PRODUCT. THE LIMITATIONS CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO INJURY TO THE PERSON. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR EXCLUSIONS OR LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
APPLICABLE LAW :
THE TERMS AND CONDITIONS EXPRESSED HEREIN SHALL BE CONSTRUED AND GOVERNED IN ACCORDANCE WITH THE LAWS OF THE STATE OF TEXAS.
© 2023 Beckett Corporation 3250 Skyway Circle N. Irving TX 75038
www.BeckettUS.com
Toll-Free: 1-866-466-4319
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>