Beckett pumps are carefully inspected and tested to ensure both safety and operating performance. However, failure to follow the instructions and warnings in this manual may result in pump damage and/or serious injury. Be sure to read and save this manual for future reference.
P erformance: 1 0GPH | Power Requirements: | 120V,60Hz, 0.16A |
---|---|---|
Shut off (max): 4. ft | Cord Length: | 16ft |
As the pump circulates water through the filter the UV exposure produces clean clear water.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THIS MANUAL FOR FUTURE REFERNCE
WARNING
- The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying water pumps. See your electrical supplies dealer for this device.
- Do not remove the grounding pin from the plug.
- Do not connect to any voltage other than shown on the pump.
- Do not pump flammable liquids.
- Do not use with water above 86º Fahrenheit (30ºC).
- To reduce the risk of electric shock, use only on portable self-contained fountains no larger than 5 feet in any dimension.
- Risk of electrical shock. This pump is supplied with a grounding conductor and ground attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
- Ensure that the electrical cord loops below the electrical outlet to form a “Drip Loop”. This will prevent water from running down the cord into the electrical outlet.
- Never directly touch the UV bulb – oil from your fingers can shorten bulb life.
- If the UV’s internal components get wet, unplug the unit immediately.
- Do not operate the UV Assembly with a missing or damaged Quartz sleeve.
- The pump cover is provided with an interlock to reduce the risk of excessive ultraviolet radiation. Do not defeat its purpose or attempt to service without removing the screen cover completely.
CAUTION
- Always disconnect from electrical outlet before handling the pump.
- Do not let the pump run dry.
- Do not lift the pump by the power cord.
- Do not pump heated liquids.
- Operate in freshwater only.
- Operate pump completely submerged for proper cooling.
- Do not look directly at UV lamp.
CAUTION!
Do not look directly at UV lamp.
ATTENTION
In order to get best results, operate pump completely submerged. Keep the
water level above the top of the pump at ALL TIMES.
Parts Detail:
- Enclosure housing
- Volute Cover
- O-rings
- Impeller
- Cap with power cord
- 3 watt UV bulb (E17)
- Quartz Glass
- Rubber Seal
- Seal Nut
MAINTENANCE
Prior to performing any maintenance always unplug the entire unit.
A clogged or dirty intake screen will greatly reduce performance.
If the pump is used on a dirty surface, raise it slightly to reduce the amount
of debris contacting the intake.
If less flow is desired, adjust it with the flow control. Never restrict the
pump’s intake.
To clean the pump, remove the front plate and the impeller. Use a small brush
or stream of water to remove any debris.
CAUTION: The pump shaft cannot be removed.
IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING:
-
Check the circuit breaker and try another outlet to ensure the pump is getting electrical power.
NOTE: always disconnect from electrical outlet before handling the pump. -
Check the pump discharge and tubing for kinks and obstructions. Algae build up can be flushed out with a garden hose.
-
Check the intake screen to ensure it is not clogged with debris.
-
Remove the pump inlet to access the impeller area. Turn the impeller to ensure it is not broken or jammed.
-
If the impeller area is encrusted with minerals or corrosion, gently scrape the area clean.
-
If your pump has been idle for an extended period, it may be necessary to apply a drop of light oil to the shaft and spin the impeller by hand until it turns freely.
-
Monthly maintenance will add to your pump’s life.
Please read the WARNINGS and CAUTIONS before removing or replacing the UV
bulbs.
3 Times A Year:
Wait for the Unit to cool off before wiping the Quartz sleeve with a clean
cloth and rinsing with clean water only – never use chemical’s
Once Every Year:
Replace UV bulb (#6) once every year for optimal water clarity.
WINTERIZING
Allowing the UV Unit to freeze may result in breakage to the quartz sleeve and
bulb. Winterize when water temperatures reach 40°F. Keep Products safely
packed away until spring when the everyday water temperature rises to 40°F or
higher.
To winterize the UV:
- Remove all plugs from the electrical outlets.
- Set the UV Unit aside and allow it to thoroughly cool.
- Dry and wipe each part within the Unit with a dry clean cloth. Remember! Do not touch the bulb with your bare fingers!
- Put the UV Unit back together.
- Store the Unit in a safe place to prevent breaking or falling off a shelf.
LIMITED WARRANTY
Each Beckett Corporation (“Beckett”) product is warranted to be free from defects in material and workmanship for the applicable Warranty Period (herein so called) set forth below. The Warranty Period for each product commences on the date of purchase by the original purchaser. The Warranty Periods are as follows:
Product Type or Name
Warranty Period
Pump Models:
FR Series, DP800-1800, G Series, FC Series ………… 2 Years
BK17/22 Series …………………………………. 2 Years
Other Pump Models ………………………………..1 Year
Pre-Formed Poly Ponds……………………….…15 Years
Waterfall Weir & Skimmer…………………….……. 5 Years
Product Type or Name
Warranty Period
Liner Material:
35 mil PVC……………………………20 Years
40 mil EPDM…………………………… 20 Years
20 mil PVC……………………………15 Years
UV9/UV13 Filter………………………….. 1 Year
All Other Beckett Products.…………………………90 Days
APPLICATION: The warranty covers only properly installed and maintained Beckett products and is limited to application at normal temperature 32º F to 86º F, (0º C to 30º C) pumping fluids with a specific gravity up to 1.1 and with a pH range of 5 to 9 (fresh water). Other liquid applications and extreme temperature uses must be approved in advance by Beckett. The warranty does not apply to or cover damages or defects caused by external causes, including, but not limited to, improper or faulty installation or unauthorized modification, lightning, electrical surges, abuse, misuse or abnormal use or misapplication, including use in a manner inconsistent with the product’s intended function. The purchaser is responsible for determining the suitability of the product for its intended use. If products are damaged in transit, a claim should be filed with the carrier.
REMEDY: If there has been a failure to conform to the warranty, Beckett will, at Beckett’s option, repair, replace or issue a credit or refund for the particular nonconforming product or part. Repair, replacement, credit or refund, at Beckett’s option, is the exclusive remedy in the event of a failure to conform to the warranty. Warranty claims must be made within 3 months after expiration of the applicable Warranty Period. ADMINISTRATION: Warranty claims must be made by calling Beckett Corporation, Customer Service Dept., telephone 866-466-4319, or by emailing CustomerService@BeckettUS.com. Proof of purchase is required, and a shipping and handling fee applies to all warranty replacements.
INSTALLATION, REMOVAL AND/OR SHIPPING CHARGES: The warranty does not cover any
costs associated with the installation, removal or shipping of products
subject to warranty claims.
DISCLAIMER AND LIMITATION: THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE
ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES, WHETHER ORAL
OR WRITTEN, EXPRESS OR IMPLIED. TO THE FULL EXTENT PERMITTED BY LAW, BECKETT
EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT
LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED, ALL SUCH
IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS
WARRANTY.
BECKETT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN
THIS WARRANTY. IN NO EVENT SHALL BECKETT BE LIABLE OR RESPONSIBLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES. BECKETT’S AGGREGATE LIABILITY UNDER THIS
WARRANTY OR WITH RESPECT TO ANY PRODUCT COVERED HEREBY, UNDER ANY LEGAL
THEORY, SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE NONCONFORMING
PRODUCT. THE LIMITATIONS CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO INJURY
TO THE PERSON. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR EXCLUSIONS OR LIMITATIONS ON THE
DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY
NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY
ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
APPLICABLE LAW: THE TERMS AND CONDITIONS EXPRESSED HEREIN SHALL BE CONSTRUED
AND GOVERNED IN ACCORDANCE WITH THE LAWS OF THE STATE OF TEXAS.
NOTICE
Remove the foam before use.
HOW TO REMOVE OR REPLACE THE UV BULB
STEP 1: Dry the water on the Glass Tube (#7).
STEP 2: Screw out the Seal Nut (#9) by counter clockwise.
STEP 3: To remove glass tube (#7) you must gently pull it left/right and up/down as you pull to loosen it. Once it starts to move you can rotate it as you pull to remove it.
STEP 4: Replace the UV bulb (#6) with a new one.
STEP 5: Add a very small amount of common household vegetable cooking oil to
the bottom of the glass tube (#7). Re-install the glass tube (#7) by pushing
and rotating until the line on the glass tube (#7) reaches the top of thread.
STEP 6: Be sure the rubber seal(#8) is bottomed out. Then re-install the seal
nut (#9) hand tight.
© 2023 Beckett Corporation
3250 Skyway Circle N.
Irving TX 75038
www.BeckettUS.com