Gude OR 1500-7 Oil Filled Radiator Instruction Manual
- June 10, 2024
- Gude
Table of Contents
Gude OR 1500-7 Oil Filled Radiator
Technical Data
Oil-filled radiator | OR 1500-7 |
---|---|
Article no. | 85190 |
Degree of protection/ Protection class | IP X0 / I |
Mains voltage | 220 – 240 V |
Mains frequency | 50 Hz |
Heating power | 1.5 kW |
Number of heating levels | 3 |
Heating levels | 0.6 / 0.9 / 1.5 kW |
Number of radiators | 7 |
Length of connection cable | 150 cm |
Noise level indication LWA | 30 dB |
Dimensions L x W x H | 340 x 240 x 650 mm |
Net/gross weight | 7,3 kg / 8,0 kg |
Heating power
Nominal heating power| Pnom| 1.5 kW
Minimum heating power (indicative)| Pmin| 0.0 kW
Maximum heating power| Pmax| 1.5 kW
Additional power consumption
At nominal heating power| max| 0.0 kW
At minimum heating power| Elgin| 0.0 kW
In standby mode| else| 0.0 kW
Type of heat supply, only for electric
storage space heaters (choose one)
Manual heating cost control with integrated thermostat| –
Manual heating cost control with room and/or outdoor temperature recording| –
Manual heating cost control with room and/or outdoor temperature recording| –
Fan-assisted heat output| –
Type of heat output/room temperature control
(choose one)
One-stage heat output without room temperature control| –
Two or more manual stages without room temperature control| –
With room temperature control using a mechanical thermostat| **
With electronic room temperature control| –
Electronic room temperature control plus day timer| –
Electronic room temperature control plus week timer| –
Other control options (multiple selections possible)**
Room temperature control with presence detection| –
Room temperature control with window opening status detection| –
With remote control option| –
With adaptive switch-on control| –
With an operating time limit| –
With the “Black Bulb” temperature sensor, black| –
Oil-filled radiator| OR 2000-9
---|---
Article no.| 85191
Degree of protection/ Protection class| IP X0 / I
Mains voltage| 220 – 240 V
Mains frequency| 50 Hz
Heating power| 2 kW
Number of heating levels| 3
Heating levels| 0.8 / 1.2 / 2 kW
Number of radiators| 9
Length of connection cable| 150 cm
Noise level indication LWA| 30 dB
Dimensions L x W x H| 420 x 240 x 650 mm
Net/gross weight| 10.4 kg / 11.3 kg
Heating power
Nominal heating power| Pnom| 2.0 kW
Minimum heating power (indicative)| Pmin| 0.0 kW
Maximum heating power| Pmax| 2.0 kW
Additional power consumption
At nominal heating power| max| 0.0 kW
At minimum heating power| Elgin| 0.0 kW
In stand-by mode| else
| 0.0 kW
Type of heat supply, only for electric
storage space heaters (choose one)
Manual heating cost control with integrated thermostat| –
Manual heating cost control with room and/or outdoor temperature recording| –
Manual heating cost control with room and/or outdoor temperature recording| –
Fan-assisted heat output| –
Type of heat output/room temperature control
(choose one)
One-stage heat output without room temperature control| –
Two or more manual stages without room temperature control| –
With room temperature control using a mechanical thermostat| **
With electronic room temperature control| –
Electronic room temperature control plus day timer| –
Electronic room temperature control plus week timer| –
Other control options (multiple selections possible)**
Room temperature control with presence detection| –
Room temperature control with window opening status detection| –
With remote control option| –
With adaptive switch-on control| –
With an operating time limit| –
With the “Black Bulb” temperature sensor, black| –
Oil-filled radiator| OR 2000-9 DT
---|---
Article no.| 85192
Degree of protection/ Protection class| IP X0 / I
Mains voltage| 220 – 240 V
Mains frequency| 50 Hz
Heating power| 2 kW
Number of heating levels| 3
Heating levels| 0.8 / 1.2 / 2 kW
Number of radiators| 9
Length of connection cable| 150 cm
Noise level indication LWA| 30 dB
Dimensions L x W x H| 420 x 240 x 650 mm
Net/gross weight| 10,54 kg / 11,4 kg
Heating power
Nominal heating power| Pnom| 2.0 kW
Minimum heating power (indicative)| Pmin| 0.0 kW
Maximum heating power| Pmax| 2.0 kW
Additional power consumption
At nominal heating power| max| 0.0 kW
At minimum heating power| Elgin| 0.0 kW
In standby mode| else| 0.001 kW
Type of heat supply, only for electric
storage space heaters (choose one)
Manual heating cost control with integrated thermostat| –
Manual heating cost control with room and/or outdoor temperature recording| –
Manual heating cost control with room and/or outdoor temperature recording| –
Fan-assisted heat output| –
Type of heat output/room temperature control
(choose one)
One-stage heat output without room temperature control| –
Two or more manual stages without room temperature control| –
With room temperature control using a mechanical thermostat| –
With electronic room temperature control| **
Electronic room temperature control plus day timer| –
Electronic room temperature control plus week timer| –
Other control options (multiple selections possible)**
Room temperature control with presence detection| –
Room temperature control with window opening status detection| –
With remote control option| –
With adaptive switch-on control| –
With an operating time limit| –
With the “Black Bulb” temperature sensor, black| –
Oil-filled radiator| OR 2500-11 DT
---|---
Article no.| 85193
Degree of protection/ Protection class| IP X0 / I
Mains voltage| 220 – 240 V
Mains frequency| 50 Hz
Heating power| 2.5 kW
Number of heating levels| 3
Heating levels| 1.0 / 1.5 / 2.5 kW
Number of radiators| 11
Length of connection cable| 150 cm
Noise level indication LWA| 30 dB
Dimensions L x W x H| 500 x 240 x 650 mm
Net/gross weight| 12,4 kg / 13,4 kg
Heating power
Nominal heating power| Pnom| 2.5 kW
Minimum heating power (indicative)| Pmin| 0.0 kW
Maximum heating power| Pmax| 2.5 kW
Additional power consumption
At nominal heating power| max| 0.0 kW
At minimum heating power| Elgin| 0.0 kW
In standby mode| else| 0.001 kW
Type of heat supply, only for electric
storage space heaters (choose one)
Manual heating cost control with integrated thermostat| –
Manual heating cost control with room and/or outdoor temperature recording| –
Manual heating cost control with room and/or outdoor temperature recording| –
Fan-assisted heat output| –
Type of heat output/room temperature control
(choose one)
One-stage heat output without room temperature control| –
Two or more manual stages without room temperature control| –
With room temperature control using a mechanical thermostat| –
With electronic room temperature control| **
Electronic room temperature control plus day timer| –
Electronic room temperature control plus week timer| –
Other control options (multiple selections possible)**
Room temperature control with presence detection| –
Room temperature control with window opening status detection| –
With remote control option| –
With adaptive switch-on control| –
With an operating time limit| –
With the “Black Bulb” temperature sensor, black| –
EXPLANATION REGARDING THIS MANUAL
These operating instructions are only valid for the devices specified in the
title. Do not use the device until you have read the operating instructions
carefully. If
you have any doubts about the connection and operation of the device, please
contact customer service. Warnings and Safety Instructions.
Danger
Indicates a hazardous situation that will result in serious injury or death.
Warning
Indicates a hazardous situation that may result in serious injury or death.
Caution
Indicates a hazardous situation that may result in minor or medium injury or
death.
Note
Indicates a situation that may lead to property damage. You can also find
additional information here.
Safety
Read all safety warnings and instructions. Failure to follow the safety
warnings and instructions can result in serious personal injury and/or
property damage.
Intended Use
The oil-filled radiator may only be operated in indoor areas that are
protected against humidity. This device is intended exclusively for heating in
private households. It is only suitable for well-insulated rooms or occasional
use. When using the device, the respective local building and fire protection
regulations as well as the necessary electrical fuse protections must always
be observed. This device may only be used for its intended purpose as
specified. If the provisions of the generally applicable regulations and the
provisions of this manual are not observed, the manufacturer cannot be held
responsible for the damage.
Prohibited Uses
- The device is not suitable for commercial or industrial use.
- Do not install the device in explosive or flammable areas.
- The device is not intended for drying clothes or for assembly under benches or in floor ducts.
- The device must not be used outdoors.
- The device must not be used for wall or ceiling mounting.
Symbols on the Device
- Warning of hot surfaces! Risk of burns!
- Warning: To prevent the heater from overheating, the heater must not be covered.
- Read the operating instructions to reduce the risk of injury.
- Electrical or electronic devices that are defective and/or need to be disposed of must be discarded at the designated recycling points.
- European Conformity Mark.
Important Safety Instructions
This device can be used by children from the age of 8 and by persons with limited physical, sensory or mental abilities or a lack of experience and/or knowledge if they are supervised or have been instructed in the safe use of the product and, have understood the resulting hazards. Children are not allowed to play with the product. Cleaning and user maintenance shall not be made by children without supervision. Children under the age of 3 should not approach the product unless they are under constant supervision. Children between 3 and 8 years of age may only switch the product on and off if it has been installed and positioned in accordance with normal usage regulations and they are supervised and have been adequately instructed in the correct and safe use and have understood the potential hazards. Children between 3 and 8 years of age are not allowed to connect, adjust, clean or carry out maintenance operations on the product.
Caution: Some parts of the device can become very hot and cause burns.
Exercise particular caution in the presence of children or vulnerable people.
Do not leave the device unattended when in use. The radiators of the device
get very hot during operation. Do not touch the hot surfaces. Only move the
device during operation by pulling the handle. To prevent the device from
overheating, it must not be covered. Do not use or store explosive or
flammable substances (such as gasoline, paper, or paint) around the product..
Always pull out the power plug when the device is not in use or to clean it.
Do not pull on the cable as you may damage the device. Make sure that the
device or the cable is not damaged by sharp objects or otherwise. Before
commissioning, check the cable for damage. Do not operate the device if the
power cord or plug is damaged. Damaged power cords or power plugs must be
replaced by the manufacturer, their customer service, or an electrician.
Protect electrical parts against moisture. To avoid electric shock, never
immerse electrical parts in water or other liquids during cleaning or
operation. Never hold the device under running water. Control elements must
not be touched by persons in the water. Always ensure that your hands are dry
before touching the controls on the device or the power plug for the main
connection. Before storage, assembly, conversion, transport, cleaning, or
maintenance work, always switch off the device and disconnect it from the
power supply by pulling the mains plug. Then allow the device to cool down.
Make sure that no foreign objects get into the ventilation slots. There is a
risk of electric shock, fire, or damage to the device. Do not block the
ventilation slots with objects. Keep the device clean. The most common causes
of overheating are dust or particle build-up in the device. You should
periodically remove these deposits by turning off the unit and cleaning the
air vents using a vacuum cleaner. Do not use the device with a program switch,
a timer, a separate remote control system, or any other device that switches
the oil-filled radiator on automatically, as there is a risk of fire if the
oil-filled radiator is covered or installed incorrectly.
Commissioning
Delivery
Note
Please have visible damage to the outer packaging confirmed by the driver of
the parcel service immediately upon delivery. If transport damage is only
noticed during unpacking, the parcel service must be notified in writing
within 24 hours of delivery in order to make them liable for the damage.
Scope of delivery
Position number | Quantity | Parts |
---|---|---|
1 | 1 | Oil-filled radiator |
2 | 4 | Rollers |
3 | 4 | Nuts |
4 | 2 | Roller carrier |
5 | 2 | U-shaped bracket |
6 | 2 | Wing nuts |
Place of installation
When installing the device, you must observe the following:
- A safety distance of at least 90 cm must be maintained on all sides of the device from furniture and other flammable objects.
- The device must not be placed directly under a wall socket.
- Do not place the device in the immediate vicinity of a bathtub, shower, or swimming pool.
- Install the device so that the main plug is accessible at all times.
- The devices must not be installed in an atmosphere containing oil, sulfur, or salt.
- Do not install the devices in fire-endangered rooms (e.g. Wooden shed).
- Never place the device near a gas or electric burner.
- No flammable materials should be within a radius of 1 m.
- The device must not be set up outdoors!
Mounting of the rollers
Caution
The danger of tipping! For better stability and improved handling, the rollers
must be mounted before use.
Note
Before installation, place a suitable blanket under the device to avoid
damage.
- Turn the oil-filled radiator [1] upside down or lay it on its side.
- Place the U-shaped brackets [5] between the first and second ribs and between the penultimate and last radiators.
- Pass the ends of the brackets [5] through the holes in the roller carriers [4].
- Fasten the brackets [5] and the roller carriers [4] using the wing nuts [6].
- Guide the rollers [2] from below into the outer holes of the roller carrier [4] and fasten them from above with the nuts [3] provided.
Electrical connection
Warning
Overload! When using an extension cable, these should have a cable cross-
section of at least 1.5 mm². It is not allowed to use multiple sockets. Do not
connect any other powerful devices to the circuit.
Caution Tripping hazard Lay the power cord in a place where no one can trip over it.
Note
Never pull the device by the power cord but use the handle provided for this
purpose.
- Completely unwind the power cord.
- Make sure that the device voltage (see rating plate) and the mains voltage match.
- Switch the power switch to position 0 (only valid for OR 2000-9 DT & OR 2500-11 DT)
- Only connect the mains plug to a properly installed safety socket.
Connection value
Danger: Electric shock! Connect the devices via a separate supply line with a 16 A fuse protection (household circuit breaker).
The devices described here can absorb the following power:
- OR 1500-7 = 1500 W
- OR 2000-9 = 2000 W
- OR 2000-9 DT = 2000 W
- OR 2500-11 DT = 2500 W
Safety switch/tilt protection
Warning:
Risk of burns! After tipping over, the device will switch off automatically.
Wait until the device has cooled down before putting it up.
Note:
Always place the device straight to avoid malfunctions.
The oil-filled radiator is equipped with a safety switch. This safety switch
turns off the power if the device tips over. Furthermore, this switch prevents
dangerous situations caused by overheating.
Application notes
Caution:
Overheating! The device does not have an external switching device such as
supplying a timer or connecting to a circuit that is regularly switched on and
off by a system. This may lead to the unintentional resetting of the
protective temperature limiter.
Overview
Overview OR 1500-7
Position | Function (OR 1500-7) |
---|---|
1 | Power level switch 1 |
2 | Power level switch 2 |
3 | Thermostatic control |
4 | Power cord |
5 | Cable winder |
Operation OR 1500-7
Setting the heating power
- Plug the power cord into an appropriate outlet. Make sure your power supply is properly protected.
- Use the power level switches [1+2] to set the desired power.
- Button [1] = level 1 (600 W)
- Button [2] = level 2 (900 W)
- Button [1+2] = level 3 (1500 W)
Temperature setting
The desired temperature (high/low) can be set using the thermostatic control
[3].
As soon as the desired room temperature is reached, the integrated thermostat
switches on and off automatically, thus ensuring an almost constant tem-
perature. As long as the device is heating up, the LEDs on the switches
[1+2] light up. As soon as the desired temperature is reached, the LEDs
turn off.
Switching off the device
- Switch off the device using the power level switches [1+2].
- Set the thermostat control [3] to LOW.
- Pull out the power cord from the wall outlet.
Overview OR 2000-9
Position | Function (OR 2000-9) |
---|---|
1 | Power level switch 1 |
2 | Power level switch 2 |
3 | Thermostatic control |
4 | Indicator light |
5 | Power cord |
6 | Handle |
7 | Cable winder |
Operation OR 2000-9
Setting the heating power
- Plug the power cord into an appropriate outlet. Make sure your power supply is properly protected.
- Use the power level switches [1+2] to set the desired power.
- Button [1] = level 1 (800 W)
- Button [2] = level 2 (1200 W)
- Button [1+2] = level 3 (2000 W)
Temperature setting
The desired temperature (high/low) can be set using the thermostatic control
[3].
As soon as the desired room temperature is reached, the integrated thermostat
switches on and off auto-matically, thus ensuring an almost constant
temperature. As long as the device is heating up, the indicator light [4]
lights up. As soon as the desired temperature is reached, the indicator light
turns off.
Switching off the device
- Switch off the device using the power level switches [1+2].
- Set the thermostat control [3] to LOW.
- Pull out the power cord from the wall outlet.
Overview OR 2000-9 DT & OR 2500-11 DT
Position | Function (OR 2000-9 DT & OR 2500-11 DT) |
---|---|
1 | Power switch |
2 | Power level switch |
3 | Display |
4 | Mode button |
5 | °C / °F button |
6 | + button |
7 | – button |
8 | Power cord |
9 | Handle |
10 | Cable winder |
Operation OR 2000-9 DT & OR 2500-11 DT
Setting the heating power
- Plug the power cord into an appropriate outlet. Make sure your power supply is properly protected.
- Switch on the device with the mains switch [1] (beep sounds and the switch lights up red).
- Use the power level button [2] to set the desired heating power.
- Press button 1x = high power
- (OR 2000-9 DT: 2000 W / OR 2500-11 DT: 2500 W) Press button 2x = medium power
- (OR 2000-9 DT: 1200 W / OR 2500-11 DT: 1500 W) Press button 3x = low power
- (OR 2000-9 DT: 800 W / OR 2500-11 DT: 1000 W) Press button 4x = device is on standby
Note:
The power levels are indicated by small symbols at the top right of the display [3].
Temperature setting
-
Use the power switch [1] to switch on the device.
-
Press the power level button [2].
The number “88” flashes on the display [3]. -
Press the mode button [4].
The display [3] shows “24 °C” (or 75 °F) and a flashing thermometer symbol. -
Use the °C / °F button [5] to select the desired unit for the temperature display.
-
Use the + [6] and – [7] buttons to set the desired temperature. The temperature value is shown on the display [3] and can be changed at any time.
Note
When the desired temperature is reached, the thermometer symbol lights up
continuously. If the temperature drops and the device has to heat up, the
thermometer symbol flashes again.
Programming the switch-off time (AUTO OFF).
This function is used to set when the oil-filled radiator switches off
automatically.
- Once the temperature is set, press the mode button [4] again. “AUTO OFF” flashes on the display [3].
- Use the + [6] and – [7] buttons to set a time between 1 and 24 hours.
- The “AUTO OFF” indicator lights up continuously after approx. 10 seconds. The oil-filled radiator will then switch off at the set time.
Programming the switch-on time (AUTO ON).
This function is used to set when the oil-filled radiator switches on
automatically.
- Once the temperature is set, press the mode button [4] twice. “AUTO ON” flashes on the display [3].
- Use the + [6] and – [7] buttons to set a time between 1 and 24 hours.
- The “AUTO ON” indicator lights up continuously after approx. 10 seconds. The oil-filled radiator will then start heating at the set time.
Switching off the device
- Keep pressing the power level button [1] until the display [3] turns off.
- Use the mains switch [3] (position 0) to switch off the device.
- Pull out the power cord from the wall outlet.
Troubleshooting
Problem | Cause | Solution |
---|
Device without function
|
The device has no power supply
| Check the outlet
Plug in the mains plug
correctly
Check the building fuse
The device is faulty| Contact customer service or a professional
The device does not heat up
| A too-low temperature has been set| Set a higher temperature
AUTO ON
accidentally programmed
| Turn on the device directly
The device switches off during the operation
| The thermal fuse has been triggered| Contact customer service
The room temp. is above the temp set on the thermostat.| Increase thermostat
temperature
The overheating protection has been triggered
| Switch off the device and pull out the power plug.
Eliminate the cause of the overheating before restarting the
device.
The safety switch/tilt protection has been triggered
| Make sure that the device is positioned vertically and is not subject to
extreme inclination.
AUTO ON or AUTO OFF has been triggered| Check the AUTO ON and AUTO OFF
settings
Cleaning and maintenance
Danger
Electric shock and/or fire! Before cleaning, always switch off the device,
pull out the mains plug and let the device cool down.
Never put/immerse the device in water for cleaning, as this could lead to an
electric shock or fire.
Note
Do not use wire brushes or other sharp-edged or abrasive objects for cleaning.
Do not use caustic/abrasive cleaning agents.
- Use a dry cloth to remove dust from the device.
- A slightly damp cloth can be used to remove stains.
Repair work and work not described in these instruc-tions may only be carried
out by qualified and skilled personnel. Only use original accessories and
original spare parts. Always keep the device, especially the ventilation
slots, clean.
The oil-filled radiator is filled with a precisely adjusted amount of special
oil. Repairs that require opening the device are reserved exclusively to the
manu-facturer or their customer service. Any leaks must be reported
immediately to the manufacturer or its customer service.
Storage
Warning
Risk of burns!
Switch off the device and let it cool down before storage.
- Clean the device (see chapter Cleaning), let it dry, and store it in the original packaging.
- Store the device in a well-ventilated and dry place out of the reach of children.
- Always wind up the power cord in the space provided for this purpose on the front of the device.
Warranty
- The warranty period is 24 months for consumers and starts at the time of purchase of the device.
- The warranty covers exclusively defects that can be traced back to material or manufacturing defects. When asserting a defect within the meaning of the warranty, the original purchase receipt with the date of purchase must be enclosed.
- Improper use, e.g. overload of the device, use of force, damage caused by external influences, or foreign objects is excluded from the warranty. Non-compliance with the operating instructions and normal wear and tear are also excluded from the warranty.
Important customer information!
Please note that returns within or outside of the warranty period should
always be in the original packaging. This measure effectively avoids
unnecessary transport damage and is often controversial regulation. Your
device is only optimally protected in the original box, thus ensuring smooth
processing.
Service
Do you have any technical questions? A claim? Do you need spare parts or
operating instructions? In the service section of our website of Güde GmbH &
Co. KG (www.guede.com), we are glad to help you
quickly and unbureaucratically. Please help us to help you. In order to be
able to identify your device in the event of a complaint, we need the serial
number, article number, and year of construction. All of this data can be
found on the rating plate.
Disposal
Warning
The danger of suffocation! Keep packaging parts out of the reach of children
and dispose of them as soon as possible.
The packaging protects the device against transport damage. The packaging materials are usually selected according to environmentally friendly and disposal-related aspects and are therefore recyclable. Returning the packaging to the material cycle saves raw materials and reduces the amount of waste. Parts of packaging (e.g. foils, Styrofoam®) can be dangerous for children. Do not dispose of electrical devices in the household waste, use the collection points in your community. Ask your municipal administration for the locations of the collection points. If electrical devices are disposed of in an uncontrolled way, dangerous substances can get into the groundwater and, thus into the food chain during weathering, or flora and fauna can be poisoned for years. If you replace the device by a new one, the seller is legally obliged to take the old one for disposal at least free of charge. When disposing of the device, the relevant regulations for the disposal of waste oil must be observed.
- Phone: + 49 (0) 79 04 / 700-360
- Fax: + 49 (0) 79 04 / 700-51999
- E-Mail : support@ts.guede.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>