PRO DG SYSTEMS IT 112 PA 2-Way Passive Speaker User Manual
- June 10, 2024
- PRO DG SYSTEMS
Table of Contents
SYSTEMS IT 112 PA 2-Way Passive Speaker
User Manual
An updated.pdf version of this manual is always available at:www.prodgsystems.com
Safety Indications
Please read it before use the system and keep for later use
PRO DG SYSTEMS GIVES YOU THANKS FOR ACQUIRE THIS PROFESSIONAL SOUND SYSTEM
FULLY DESIGNED, ASSEMBLED AND OPTIMIZED IN SPAIN, WE WISH THAT YOU ENJOY WITH
ITS HIGH QUALITY AND PERFORMANCE.
-
This system has been designed, fabricated and optimized by Pro DG Systems in perfect working order. To maintain this condition and ensure the right operation, the user must respect the following indications and advices of this manual.
THE FIABILITY, SAFETY AND EFFICIENCY OF THE SYSTEM ARE ONLY AND EXCLUSIVELY GUARANTEED BY PRO DG SYSTEMS IF: -
Assembly, manipulation, re-adjustment and modifications or repairs are carried out by Pro DG Systems.
-
The electrical installation complies with the requirements of IEC (ANSI).
-
The system is used according to the use indications.
WARNING:
- If protectors are opened or sections of chassis are removed, except where this can be done manually, live parts can become exposed.
- Any adjustment, manipulation, optimization or reparation of the system must be done only and exclusively by Pro DG Systems. PRO DG SYSTEMS IS NOT RESPONSIBLE OF ANY DAMAGE OF THE SYSTEM CAUSED BY A MANIPULATION, ADJUSTMENT, OPTIMIZATION OR REPARATION REALIZED BY NO-AUTHORIZED PERSONAL BY PRO DG SYSTEMS
- High loudspeaker levels can cause hearing damage, it must avoid the direct contact with loudspeakers operating at high levels, Dtherwise it must use hearing protectors.
MAIN CONNECTION:
- The system is designed for continuous operation
- The set operating voltage must match the local mains supply voltage.
- The unit has to be connected to the main via the supplied power unit or power cable.
- Power unit: never use a damaged connection lead. Any type of damage must be fixed.
- Avoid connection to the mains supply in distributor boxes together with several other power consumers.
- The plug socket for the power supply must be positioned near the unit and must be easily accessible.
PLACE OF SITUATION:
- The system should stand only on a clean and totally horizontal surface.
- The system must not be exposed to any type of vibration during its operation.
- Avoid the contact with the water or wet surfaces. Do not place objects containing liquid on the system.
- Procure that the system has sufficient ventilation and do not block or cover any ventilation opening. Obstruct the ventilation may cause overheating in the system.
- Avoid direct exposure to the sun, as well as proximity to sources of heat or radiation.
- If the system undergoes an extreme change in temperature may affect its operation, before starting the system hope it has reached room temperature.
ACCESSORIES:
- Do not place the system on a unsteady base that can be cause of damage to people or to the system, use it only with the trolley, rack, tripod or base recommended or supplied by Pro DG Systems following the installation indications. The system’s combination must be moved very carefully. The application of an excessive use of force and uneven floors can cause the combination of system and stand to tip over.
- Additional equipment: don’t use additional equipment wich has not be recommended by Pro DG Systems. The use of not recommended equipment can cause accidents and damage to the system.
- To protect the system during bad weather or when left unattended for prolonged periods, the main plug should be disconnected. This prevents the system being damaged by lightning and power surges in the AC mains supply.
IT IS RECOMMENDED TO THE USER READ THESE INSTRUCTIONS BEFORE USING THE SYSTEM
AND SAVE FOR LATER USE. PRO DG SYSTEMS IS NOT RESPONSIBLE OF AN INADEQUATE
USE OF THE SYSTEM BY NO-AUTHORIZED PERSONNEL WITHOUT ENOUGH KNOWLEDGE OF USE.
THE USE OF THE PRO DG SYSTEMS PRODUCTS IS INDICATED FOR AUTHORIZED
PROFESSIONALS THAT MUST TO HAVE ENOUGH KNOWLEDGE OF THE SYSTEM USE AND ALWAYS
RESPECTING THE INDICATIONS SHOWED BELOW.
DESIGNED, ASSEMBLED AND OPTIMIZED IN SPAIN
Introduction
This manual has been designed to help all the users of the system IT 112 PA of
Pro DG Systems to its correct use as well as for the understanding of the
benefits and versatility of the same. IT 112 PA is a passive multipurpose
system totally designed, assembled and optimized in Spain.
IT 112 PA
Totally designed, manufactured and optimized in Spain.
Description
IT 112 PA is a 2-way multipurpose passive system equipped with one (1) speaker
of 12″ in a tuned enclosure. The HF section has one (1) compression driver of
1/4”, coupled to one (1) rotating diffuser of 80×50. IT 112 PA incorporates
multifunction switch to work with its own crossover or biamplied. It is
perfect to be used as P.A, frontfill and sidefill with or without subwoofer,
as portable system or permanent installation. It can be used individually and
horizontally stacked or flown with two or more units together as X-Array
system of constant curvature, or vertically adapted thanks to its special
flight hardware to work as a Line Array system as well.
Technical specifications
Power Handling: | 2400 W peak / 1200 W program / 600 W RMS (EIA 426A Standard). |
---|---|
Nominal Impendence: | 8 Ohm |
Average Sensitivity: | 100 dB / 2.83V / 1m (average of 150 – 16000Hz wideband). |
Calculated Maximum SPL: | 1m 130 dB continuous / 133 dB program / 136 dB peak. |
Frequency Range: | +/- 3dB between 40 Hz – 18 KHz. |
Nominal Directivity: | 80×50 rotating diffuser. |
Low / Mid Frequency Driver: | One (1) Pro DG Systems speaker of 12”, 8 Ohm, 500 |
W.
Mid Frequency Cut-off:| 70 Hz Linkwitz-riley 24 filter – 1200 Hz Linkwitz-
riley 24 filter.
High Frequency Driver:| One (1) Pro DG Systems driver of 1/4”, 8 Ohm, 100 W.
High Frequency Cut-off:| 1200 Hz Linkwitz-riley 24 filter – 18000 Hz Linkwitz-
riley 24 filter.
Rigging points:| 12 x M10
Connectors:| 2 NL4MP speakon connectors.
Controls:| Multifunction switch to work with its own crossover or biamplied
Acoustic Enclosure:| CNC fabrication in 15mm birch plywood.
Finish:| Special textured black paint finish.
Grille / Hardware:| 2 mm metal grille with 0.5 mm acoustic foam + 2 handles
with aluminum handgrip.
Dimensions:| (HxWxD); 690x390x380mm (27,16”x15,35”x14,96”).
Weight:| 27,2 Kg (59,96 lbs) net / 28,7 Kg (63,27 lbs) with packaging.
Architectural specifications
Inside IT 112 PA
IT 112 PA counts with one Beyma speaker of 12”, 500 W (RMS). Specially
designed under our own parameters for the best performance of the system.
KEY FEATURES
High power handling: 1000 W program power 3” copper wire voice coil.
High sensitivity: 97 dB (1W / 1m)
FEA optimized ceramic magnetic circuit
Designed with MMSS technology for high control, linearity and low harmonic
distortion
Waterproof cone treatment on both sides of the cone Xmax ± 6,3 mm / Xdamage ±
30 mm
Low harmonic distortion and linear response
Specially designed under our own parameters for the best performance of the system.
Nominal diameter | 300 mm (12 in) |
---|---|
Rated Impedance | 8 Ω |
Minimum impedance | 6,5 Ω |
Power capacity | 500 W (RMS) |
Program power | 1000 W |
Sensitivity | 97 dB 1W / 1m @ ZN |
Frequency range | 45 – 5.000 Hz |
Recom. Enclosure vol. | 30 / 100 l 1,06 / 3,53 ft3 |
Voice coil diameter | 77 mm (3 in) |
Bl factor | 18 N / A |
Moving mass | 0,062 kg |
Voice coil length | 16 mm |
Air gap height | 8 mm |
Xdamage (peak to peak) | 30 mm |
**THIELE – SMALL PARAMETERS***
Resonant frequency, fs D.C. | 42 Hz |
---|---|
Voice coil resistance, Re | 5,8 Ω |
Mechanical Quality Factor, Qms | 5,6 |
Electrical Quality Factor, Qes | 0,30 |
Total Quality Factor, Qts | 0,28 |
Equivalent Air Volume to Cms, Vas | 91,1 l |
Mechanical Compliance, Cms | 229 μm / N |
Mechanical Resistance, Rms | 2,9 kg / s |
Efficiency, η0 | 2,2 % |
Effective Surface Area, Sd | 0,053 m2 |
Maximum Displacement, Xmax ** | 6,3 mm |
Displacement Volume, Vd | 334 cm3 |
Voice Coil Inductance, Le @ 1 kHz | 1 mH |
MOUNTING INFORMATION
Overall diameter | 312 mm (12,28 in) |
---|---|
Bolt circle diameter | 294,5 mm (11,59 in) |
Baffle cutout diameter:
– Front mount| 278 mm (10,94 in)
Depth| 131 mm (5,16 in)
Net weight| 5,5 kg (12,12 lb)
-
T-S parameters are measured after an exercise period using a preconditioning power test. The measurements are carried out with a velocity-current laser transducer and will reflect the long term parameters (once the loudspeaker has been working for a short period of time).
The Xmax is calculated as (Lvc – Hag)/2 + (Hag/3,5), where Lvc is the voice coil length and Hag is the air gap height.
FREE AIR IMPEDANCE CURVE
FREQUENCY RESPONSE AND DISTORTION
Note: On axis frequency response measured with loudspeaker standing on infinite baffle in anechoic chamber, 1W @ 1m
Inside IT 112 PA
IT 112 PA also incorporates a constant rotatable directivity horn specifically designed to work with one Pro DG Systems compression driver of 100 W RMS. Its constant directivity characteristics ensure the ability to cover 80º wide horizontally and 50º wide vertically (depending on its position), at virtually any frequency within its operational range.
KEY FEATURES**- Designed to work with one (1) Pro DG Systems compression driver of 100 W RMS.
- Uniform response, on and off – axis with a neutral frequency reproduction.
- Coverage angles of 80º in the horizontal plane and 50º in the vertical plane (depending on its position).
- Precise directivity control in the pass band.
- Square and compact design , providing versatile mounting options with cast aluminum construction.
TECHNICAL SPECIFICATIONS
Throat diameter | 36 mm. 1.4 in. |
---|---|
Horizontal beamwidth | 80º (+16º, -32º) (-6 dB, 1 – 20 kHz) |
Vertical beamwidth | 50º (+29º , -14º)(-6 dB, 1.6 – 20 kHz) |
Directivity factor (Q) | 12.4 (average 0.63 – 16 kHz) |
Directivity index (DI) | 10.5 dB (+3.5 dB, -3.2 dB) |
Cutoff frequency | 800 Hz |
Size (WxHxD) | 235x235x120mm (9.25×9.25×4.72in) |
Net weight | 1.2 kg (2.64 lb) |
Construction | Cast aluminum. |
Inside IT 112 PA
IT 112 PA is also composed by one Pro DG Systems compression driver of 100
W RMS coupled to a wave guide. It is specially designed under our own
parameters for the best performance of the system.
KEY FEATURES (ONE UNIT)
- High power handling: 100 W RMS.
- Lightweight PM-4 polymer diaphragm.
- Excellent high frequency response with low distortion.
- Excellent sensitivity: 111 dB, 2,83 V @ 1m.
- 200 W program power above 1,2 kHz.
TECHNICAL SPECIFICATIONS
Throat diameter | 36 mm (1.4 in) |
---|---|
Rated impedance | 8 ohms |
Minimum impedance | 5.2 ohms @ 3.5 kHz |
D.C. Resistance | 4.3 ohms |
Power capacity | 00 W RMS above 1.2 kHz |
Program power | 200 W above 1.2 kHz |
Sensitivity * | 111 dB (2.83 V @ 1m) coupled to IT-A 212 P.A. horn |
Frequency range | 0.7 – 19 kHz |
Recommended crossover | 1.2 kHz or higher (12 dB/oct. min.) |
Voice coil diameter | 44.4 mm (1.75 in) |
Magnetic assembly weight | 1.86 kg (4.1 lb) |
Flux density | 1.65 T |
BL factor | 6,6 N/A |
MOUNTING INFORMATION
Overall diameter | 120 mm (4.72 in) |
---|---|
Depth | 65 mm (2.56 in) |
Mounting | Four M5 threaded holes, 90º apart on 101,6 mm (4”) diameter circle |
Net weight (1 unit) | 2.04 kg (4.5 lb) |
CONSTRUCTION MATERIALS
Diaphragm | PM-4 polymer |
---|---|
Voice coil | Ultra lightweight edge wound aluminum voice coil |
Voice coil former | Aluminum cover |
Magnet | Ferrite |
Note: * Sensitivity was measured at 1m distance on axis with 1w input,
averaged in the range 1-7 KHz
DIMENSION DRAWINGS
FREQUENCY RESPONSE
AND DISTORTION
Note: On axis frequency response measured coupled to IT 112 P.A. horn in
anechoic chamber 2,83 v @ 1m.
FREE AIR IMPEDANCE CURVE
Note: Electrical impedance measured coupled to IT 112 P.A. horn
Hardware for installation
Tripod (Optional)
Material:| Aluminum with black powder coating. Five steps fixation (17cm each
step), it includes safety bolt.
---|---
Height:| 125cm to 195cm / 49.21” to 76.77”
Max load:| 32 Kg / 70.55 lbs.
Tube diameter:| 35mm – 1.38”
Folded Dimensions:| 1040x120x120mm 40.94×4.72×4.72 in
Interaction with subwoofers (Optional)
Extensible bar with thread for
IT 112 PA.
Material: | Reinforced steel. |
---|---|
Colour: | Black. |
Tube diameter: | 35mm – 1.38” |
Height: | 840mm – 1120mm / 33.07” – 44.09” |
Distance rod with hand crank and »Ring Lock« system from König & Meyer for IT
112 PA. (Optional)
Material: | Reinforced steel. |
---|---|
Colour: | Black. |
Tube end(s): | »Ring Lock« diameter 35 to 37 mm, threaded bolt M20. |
Height: | 920mm – 1520mm / 36.22” – 59.84” |
Height adjustment: | Hand crank with push-button system and locking screw. |
Rod combination: | 2-piece folding design. |
Features: | Patented expanding mandrel system »Ring Lock«; vibra- tion – free |
connection due to moveable plastic splints ; push – button system and hand
crank avoid uncontrolled reverse motion; locking screw provides additional
safety; M20 bolt for precise and vertical fit.
– Weight:| 3.86 kg / 8.51 lbs.
“T” support for two (2) units IT 112 PA (Optional)
– Material: | Reinforced steel. |
---|---|
– Mounting bolt: | Diameter 35x120mm / 1.38×4.72 in |
– Width: | Adjustable from 310 to 490mm.12.20 – 19.29 in. |
– Max Load: | 2 x 32 Kg / 2 x 70.55 lbs. |
Eyebolt for wall or ceiling installation (Optional)
Wall mount bracket with steel mounting pole and adjustable angulation to support up to 32 Kg (70.55 lbs) and with a length of 300mm (11.81 in) (Optional)
Flight Hardware for IT 112 P.A.
Flight Bumper to work in cluster mode.
Flight Bumper to work as Line Array system.
Flight Hardware and Bumpers to raise up to 3 units IT 112 PA horizontally adapted in cluster mode, or vertically adapted to work as Line Array system are available (Optional). Four pinlocks and one shackle are included.
Flight Bumper to raise up to 3 units IT 112 P.A. horizontally adapted in cluster mode. Flight Bumper to raise up to 3 units IT 112 P.A. vertically adapted to work as Line Array system.
In Pro DG Systems we know that making high quality speakers is an important
part of our job. Then, offering the warranty of using speakers properly is
another part which is also fundamental in our job. Good tools make the
difference for an optimal use of the system.
With Ease Focus V2 prediction software for IT 112 PA we can design different
configurations between systems and simulate their behavior in different places
and circumstances like obtain information of: coverage, frequency, SPL and
general system behavior in an easy and comfortable way. It is easy to handle
and we offer training courses for Pro DG Systems users. Click here to redirect
to the download link of EASE Focus V2.5.10. Click here to download GLL file
for IT 112 PA. For more information, consult our technical service at:
sat@prodgsystems.com
Accesories.
Complete cabling for the system is available and ready to use.
Advance progasm System
www.prodgsystems.com
References
Read User Manual Online (PDF format)