Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.

Intended use

This cross-line laser projects a clearly visible green laser cross and is suitable for aligning horizontals, verticals and inclinations. Optical signals indicate when the unit is outside its self-levelling range. The product has an integral hand-held receiver mode and a 1/4″ tripod connection.

General safety instructions

  • The device must only be used in accordance with its intendedpurpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.

Safety instructions

Using class 2 lasers

Laserliner PocketCross-Laser 2G Set - Safety
instructions

  • Attention: Do not look into the direct or reflected beam.
  • Do not point the laser beam towards persons.
  • If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
  • Under no circumstances should optical instruments (magnifying glass, microscope, binoculars) be used to look at the laser beam or reflections.
  • Do not use the laser at eye level (1.40 … 1.90 m)
  • Reflective, specular or shiny surfaces must be covered whilst laser devices are in operation.
  • In public areas shield off the laser beam with barriers and partitions wherever possible and identify the laser area with warning signs.

Safety instructions

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU.

  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply.
    Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.

  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Special product features

Laserliner PocketCross-Laser 2G Set - Special product
features

Green laser technology

Laserliner PocketCross-Laser 2G Set - Green laser
technology

Laserliner PocketCross-Laser 2G Set - PowerGreen+
technology

Number and direction of the lasers

H = horizontal laser
V = vertical laser
S = slope function

Laserliner PocketCross-Laser 2G Set - Number and direction of the lasers
2

  1. Laser output windows

  2. Slide switch
    a ON
    b OFF / Transport lock /Slope mode

  3. 1/4″ tripod threads (bottom

  4. Battery status

  5. LED levelling

  6. Laser line selection button; levelling on / off

  7. Hand receiver mode on / off

  8. LED hand receiver mode

When transporting, always switch off all lasers, secure pendulum and push the slide switch (2) to the left.

1) Use of lithium-ion rechargeable battery

  • Use the power supply/charger unit only in closed rooms; do not expose to moisture or rain otherwise risk of electric shock.
  • Ensure the device’s battery is fully charged before using the device.
  • Connect the power pack/charger to the mains power supply and the socket on the device‘s battery pack. Please only use the power pack/charger supplied. Using any other power pack/charger will invalidate the warranty.
  • The LED display flashes while the device is charging. Charging is complete when the LEDs are continuously lit.

The device has a replaceable battery. Contact your distributor or the UMAREX- LASERLINER service department.

2) Horizontal and vertical levelling

Release the transport restraint, push the slide switch (2) to the right.
The laser cross will appear. The laser lines can be switched individually with the selection button.

Laserliner PocketCross-Laser 2G Set - Horizontal and vertical
levelling

The transport restraint must be released for horizontal and vertical levelling. The laser lines flash as soon as the device is outside the automatic levelling range of 3.5°. Position the device such that it is within the levelling range. The laser lines stop flashing (steady light).

3) Slope mode

Do not release transport restraint, push slide switch (2) to the left.
Select the laser with the selector button (6). Sloping planes and tilts can now be measured. In this mode, the laser lines no longer align automatically.

Laserliner PocketCross-Laser 2G Set - Slope mode

4) Hand receiver mode

Optional: Working with the laser receiver GRX

Use an GRX laser receiver (optional) to carry out levelling at great distances or when the laser lines are no longer visible. To work with a laser receiver, switch the line laser to hand-held receiver mode by pressing button 7 (handheld receiver mode on / off). The laser lines will now pulsate with high frequency, making the laser lines darker. The laser receiver can detect these pulsating laser lines.

Observe the laser receiver‘s operating instructions for line lasers.

Preparing the calibration check

It is possible for you to check the calibration of the laser. To do this, position the device midway between 2 walls, which must be at least 5 m apart. Switch the device on (Laser cross ON). The best calibration results are achieved if the device is mounted on a tripod.

  1. Mark point A1 on the wall.
  2. Turn the device through 180° and mark point A2.
    You now have a horizontal reference between points A1 and A2.

Laserliner PocketCross-Laser 2G Set - You now have a horizontal reference
between points A1 and A2
Performing the calibration check

  1. Position the device as near as possible to the wall at the height of point A1.
  2. Turn the device through 180° and mark point A3.
    The difference between points A2 and A3 is the tolerance.

Laserliner PocketCross-Laser 2G Set - The difference between points A2 and
A3 is the tolerance

When A2 and A3 are more than 0.3 mm / m apart, an adjustment is necessary. Contact your authorised dealer or else the UMAREX-LASERLINER Service Department.

Checking the vertical line

Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on the wall, making sure that the bob can swing freely. Switch on the device and align the vertical laser to the plumb line. The precision is within the specified tolerance if the deviation between the laser line and the plumb line is not greater than ± 2 mm.

Checking the horizontal line

Position the device about 5 m from a wall and switch on the cross laser. Mark point B on the wall.
Turn the laser cross approx. 2.5 m to the right and mark point C. Check whether the horizontal line from point C is level with point B to within ± 2 mm. Repeat the process by turning the laser to the left.

Regularly check the calibration before use, after transport and after extended periods of storage.

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Store the device in a clean and dry place.

Calibration

The meter needs to be calibrated and tested on a regular basis to ensureit produces accurate measurement results. We recommend carrying out calibration once a year. Contact your authorised dealer or else the UMAREX-LASERLINER Service Department.

Laserliner PocketCross-Laser 2G Set - Technical data

EU and UK directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU and the UK.

This product, including accessories and packaging, is an electrical appliance that must be recycled in an environmentally appropriate manner in accordance with European and UK directives on waste electrical and electronic equipment, batteries and packaging, in order to recover valuable raw materials.

Further safety and supplementary notices at: http://laserliner.com

SERVICE

Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300
www.laserliner.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals