Roth Touchline PL Wireless Control Installation Guide

June 10, 2024
Roth

Roth Touchline PL Wireless Control

Roth-Touchline-PL-Wireless-Control-PRO

Product Information

The product is a control unit that needs to be connected to a 230V power source. Once clicked, it is ready for pairing with room thermostats or sensors. The product has a user manual that provides instructions for pairing with room thermostats or sensors.

  • Power Source: 230V
  • Fuse Type: Glass fuse WT 6.3A (5 x 20mm)

Product Usage Instructions

To use the product, follow the below instructions:

  1. Connect the controller unit to a 230V power source.
  2. Refer to the user manual provided with the room thermostat or sensor.
  3. Pair the room thermostat or sensor with the controller unit.
  4. Follow the instructions the room thermostat or sensor provides to set up and control the temperature.
  5. Before changing the glass fuse, turn off the 230V power source.

WARNING

Risk of fatal electric shock when touching power connections. Before working on the control unit, always switch off the power the 230V power supply and prevent it from switching on accidentally.

Roth-Touchline-PL-Wireless-Control- \(1\)

INSTALLATION

  1. Must be mounted on a flat surface, screw max. @ 3 mm.Roth-Touchline-PL-Wireless-Control- \(2\)Roth-Touchline-PL-Wireless-Control- \(3\)

  2. Thermomotor connection, connect brown to Log blue to N.Roth-Touchline-PL-Wireless-Control- \(4\)

    • Use Project thermometer 230V 1 W, VV5 no. 466275.430.
    • Max number of thermal motors = 22 pcs. (3 zones with 4 pcs. and 5 zones with 2 pcs.).
  3. A. 230V pump output, max. load 0.5 A. The cable must be secured with the traekafastnignen. The pump outlet has an integrated pump stop function.Roth-Touchline-PL-Wireless-Control- \(5\)
    B. Boiler/heating output, potential-free rela max. load 1 A.

  4. Connect 230V spending, the control unit is ready for registration of rooms mostats. Read the accompanying manual for registering room thermostats.Roth-Touchline-PL-Wireless-Control- \(6\)

  5. Glass fuse WT 6.3 A (5 × 20 mm). Disconnect the 230V voltage for Exchange.Roth-Touchline-PL-Wireless-Control- \(7\)

ROTH UK Ltd.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Roth User Manuals

Related Manuals