SAFETY INSTRUCTIONS

  • The solar panel generates a voltage when exposed to light. Follow all the relevant electrical safety regulations.
  • The product must only be installed and maintained by suitably qualified personnel.
  • Pay attention to high DC voltages when connecting solar panels.
  • Avoid scratching or otherwise damaging the back of the panel.

SYMBOLS

  • Read the instructions.
  • Approved in accordance with the relevant directives.
  • Recycle discarded products in accordance with local – regulations.

TECHNICAL DATA

  • Solar cell type Monocrystalline
  • Voltage 12 V
  • Max output (Pmax) 55 W (± 5%)
  • Open circuit voltage (V0cl 21.12 V
  • Short circuit voltage (lscl 3.4A
  • Max operating voltage (Umpl 17.92 V
  • Max operating current (lmpl 3.1 A
  • Solar cell efficiency 22 %
  • Standard test conditions AM 1.5, 1000 W/m2, 25° C
  • Operating temperature -40° C to +85°C
  • Size unfolded 700 x 580 x 2.5 mm
  • Weight 7.7 kg

DESCRIPTION

ABOUT THE SOLAR ENERGY SYSTEM
The solar energy system with flexible panels is an elegant, economic and practical system based on very effective and lightweight solar panels, joint negative terminals, and advanced, maximum power point tracking (MPPT). The operating status is shown on a display on the main unit and on an auxiliary display on the remote control panel. The MPPT controller controls the solar cells on the basis of the current operating conditions to the run point where they produce their maximum power. This can increase energy recovery by up to 20 – 30% in comparison with solar energy systems with pulse width modulation (PWM). The system has built-in overcurrent protection for the battery charging circuits as well as the option to connect external protection via the RS485 port, which makes the system very reliable and adjustable to different installation requirements. The MPPT charge controller has an adaptive three- stage charging algorithm based on digital control circuits, which increases both the life span of the batteries and system performance. The system also has electronic protection from overcharging, over-discharging, and reverse polarisation of solar panels and batteries, which makes the system very reliable and robust. The charge controller is ideal for campers, base stations for radio communication, households, monitoring of field installations, and many other applications.

INSTALLATION

POSITIONING
Choose a position for installation with as much direct solar radiation and as many unshadowed hours of sunlight per day as possible.

The installation can be done in several different ways, the most important thing is that the solar panel is not installed where the sunlight is shadowed. A suitable method is hanging from hooks or a line. The panel has pre-drilled holes for this.

CONNECTION

Up to eight 55 W solar panels can be connected to the same circuit. The diagrams show examples of installation with a single solar panel and with parallel connection of
8 solar panels with a total output of 440 W.

  1. Article number 013676
  2. Article number 013672 (accessory)
  3. Load/consumeranslut-013675-Solar-Panel-fig-1 anslut-013675-Solar-Panel-fig-2

NOTE:

  • More than 8 solar panels should NOT be connected in parallel.
  • The solar panel has been subjected to a flexural strength test of 30 degrees of curvature. Do not exceed this, and protect the panel from knocks and blows
    • risk of damaging the panel.
  • The efficiency of the solar panel can diminish in time. This is not a fault – it is normal that solar cells become less efficient over the years. External factors such as the intensity of the solar radiation at the installation point, fouling, snow, and ambient temperature, can also affect the performance of the solar panel.