Literature Library G8SA Single Stage Upflow Horizontal Gas Furnaces Owner’s Manual
- June 15, 2024
- Literature Library
Table of Contents
- Literature Library G8SA Single Stage Upflow Horizontal Gas Furnaces
- FEATURES and BENEFITS
- GAS FURNACE DIMENSIONS
- GAS FURNACE COMPONENTS
- MODEL IDENTIFICATION CODE
- SPECIFICATIONS
- ACCESSORIES
- GENERAL TERMS OF LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Literature Library G8SA Single Stage Upflow Horizontal Gas Furnaces
The gas furnace may be installed free-standing in a utility room, or basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States. This furnace series is approved and certified by the SCAQMD and the SJVAPC Districts in the state of California.
FEATURES and BENEFITS
- Ultra-low emissions: 65% less NOx than standard furnaces.
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures the product will arrive at the homeowner’s dent-free.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
- 30-second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower-off settings (60, 90, 120 and 180 seconds).
- 30-second post purge: Increases the life of the heat exchanger.
- Hot surface igniter: Innovative application of a silicon nitride igniter.
- Colour-coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- High static blowers: All models are equipped with high static blowers.
- 60-second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
- Flexible category I venting system: This may be vented with the dedicated venting system or a common vent with other category one appliances.
- High-efficiency blower kits: Maximize efficiencies and provide better temperature control, humidity control and air distribution.
- Multi-speed direct drive blower: Energy-efficient, brushless DC (ECM). Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra-easy motor speed selection.
- Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy-to-recognize states without counting flashes.
- Integrated control board: Incorporates connections for electronic air cleaner and humidifier. Ergonomically located for ease of service.
- Two-piece door design: Enhances furnace appearance and uses captured screws to prevent losing the door screws.
- Blower Compartment: Insulated for ultra-quiet operation.
- Furnace Air Leakage: These furnaces comply withEnergy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing t o where it’s needed.
GAS FURNACE DIMENSIONS
GAS FURNACE COMPONENTS
MODEL IDENTIFICATION CODE
SPECIFICATIONS
KG8SA MODEL NUMBERS | -055U-T23A1 | -100U-T35A1 |
---|---|---|
Input – Btuh (a) | 55000 | 100000 |
Heating Capacity – BtuH | 44000 | 80000 |
AFUE | 80.0 | 80.0 |
Motor H.P. – Speed – Type | 1/2 – 5 – ECM | 1 – 5 – ECM |
Motor FLA | 6 | 11 |
Rated Ext. SP – In. W.C. | 0.5 | 0.5 |
Temperature Rise Range – F | 35-65 | 35-65 |
Shipping Weights | 107 | 144 |
NOx | <14ng/J | <14ng/J |
SKU | 1021589K | 1021594K |
ACCESSORIES
KG8SA KITS
Description| SKU
Side return filter kit| 541036
Airflow Data
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
MODEL NAME/ HEATING INPUT
| ****
RETURN AIR VIA:
| MOTOR SPEED TAP| EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1| 0.2| 0.3| 0.4| 0.5
CFM| RISE| CFM| RISE| CFM| RISE| CFM|
RISE| CFM| RISE
-055U 55,00 BTU/Hr
| ****
Bottom
| 5 – High | | | | | | | | | |
4 – Med-High| | | | | | | | | |
3 – Med-Low | 880| 46| 845| 48| 810| 50| 770| 53| 735| 55
2 – Alternate| 705| 58| 650| 63| 610| | 570| | 530|
1 – Low | 640| 64| 600| | 555| | 510| | 470|
Side
| 5 – High | | | | | | | | | |
4 – Med-High| | | | | | | | | |
3 – Med-Low | 875| 47| 830| 49| 795| 51| 750| 54| 715| 57
2 – Alternate| 685| 59| 650| 63| 595| | 555| | 515|
1 – Low | 640| 64| 585| | 540| | 500| | 460|
COOLING AIRFLOW (CFM)
COOLING AIRFLOW (CFM)
MODEL NAME/ HEATING INPUT
| ****
RETURN AIR VIA:
| MOTOR SPEED TAP| EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| CFM| CFM| CFM| CFM| CFM| CFM| CFM
-055U 55,00 BTU/Hr
| ****
Bottom
| 5 – High | 1,180| 1,140| 1,110| 1,080| 1,045| 1,015| 985| 955
4 – Med-High| 920| 880| 850| 810| 775| 740| 700| 665
3 – Med-Low | 880| 845| 810| 770| 735| 700| 665| 630
2 – Alternate| 705| 650| 610| 570| 530| 480| 440| 400
1 – Low | 640| 600| 555| 510| 470| 430| 390| 340
Side
| 5 – High | 1,160| 1,125| 1,095| 1,065| 1,040| 1,010| 975| 945
4 – Med-High| 905| 860| 827| 790| 755| 717| 683| 639
3 – Med-Low | 875| 830| 793| 752| 715| 684| 642| 606
2 – Alternate| 685| 650| 595| 555| 515| 471| 424| 376
1 – Low | 640| 585| 540| 500| 460| 415| |
NOTES
- To comply with government-mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
- Data is shown without a filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Individual cells shaded in grey indicate a temperature rise outside of the recommended range.
- To comply with government-mandated efficiency standards, speed settings shaded in grey are not allowed in HEAT mode.
- The “” denotes the factory COOL setting, “” denotes the factory HEAT setting, and “” denotes the factory FAN setting. If the Alternate speed is to be used, the speed tap must be adjusted at the blower motor plug.
Airflow Data (Cont.)
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
MODEL NAME/ HEATING INPUT
| ****
RETURN AIR VIA:
| MOTOR SPEED TAP| EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1| 0.2| 0.3| 0.4| 0.5
CFM| RISE| CFM| RISE| CFM| RISE| CFM|
RISE| CFM| RISE
G8SA-100U-T35C1 100,00 BTU/Hr
| ****
Bottom
| 5 – High | | | | | | | | | |
4 – Med-High| | | | | | | | | |
3 – Med-Low | 880| 46| 845| 48| 810| 50| 770| 53| 735| 55
2 – Alternate| 705| 58| 650| 63| 610| | 570| | 530|
1 – Low | 640| 64| 600| | 555| | 510| | 470|
Side
| 5 – High | | | | | | | | | |
4 – Med-High| | | | | | | | | |
3 – Med-Low | 875| 47| 830| 49| 795| 51| 750| 54| 715| 57
2 – Alternate| 685| 59| 650| 63| 595| | 555| | 515|
1 – Low | 640| 64| 585| | 540| | 500| | 460|
Side + Bottom or
2 Sides
| 5 – High | | | | | | | | | |
4 – Med-High| | | | | | | | | |
3 – Med-Low | 1,600| 46| 1,530| 48| 1,460| 51| 1,400| 53| 1,340| 55
2 – Alternate| 1,525| 49| 1,455| 51| 1,390| 53| 1,330| 56| 1,265| 59
1 – Low | 1,370| 54| 1,300| 57| 1,230| 60| 1,150| 64| 1,090|
COOLING AIRFLOW (CFM)
MODEL NAME/ HEATING INPUT
| ****
RETURN AIR VIA:
| MOTOR SPEED TAP| EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| CFM| CFM| CFM| CFM| CFM| CFM| CFM
G8SA-100U-T35C1 100,00 BTU/Hr
| ****
Bottom
| 5 – High | 2,310| 2,260| 2,200| 2,150| 2,100| 2,040| 1,990| 1,940
4 – Med-High| 1,870| 1,820| 1,760| 1,720| 1,670| 1,610| 1,560| 1,490
3 – Med-Low | 1,580| 1,530| 1,480| 1,420| 1,360| 1,290| 1,230| 1,155
2 – Alternate| 1,500| 1,450| 1,400| 1,340| 1,280| 1,210| 1,130| 1,050
1 – Low | 1,390| 1,320| 1,260| 1,200| 1,130| 1,060| 970| 890
Side
| 5 – High | 2,160| 2,100| 2,060| 2,020| 2,050| 1,990| 1,950| 1,880
4 – Med-High| 1,810| 1,750| 1,710| 1,660| 1,620| 1,560| 1,510| 1,440
3 – Med-Low | 1,540| 1,490| 1,440| 1,380| 1,330| 1,270| 1,210| 1,150
2 – Alternate| 1,470| 1,420| 1,360| 1,310| 1,260| 1,200| 1,130| 1,070
1 – Low | 1,310| 1,250| 1,190| 1,150| 1,080| 1,000| 950| 880
Side + Bottom or
2 sides
| 5 – High | 2,280| 2,220| 2,170| 2,120| 2,090| 2,080| 2,020| 1,950
4 – Med-High| 1,880| 1,820| 1,770| 1,720| 1,670| 1,610| 1,560| 1,490
3 – Med-Low | 1,600| 1,530| 1,460| 1,400| 1,340| 1,270| 1,200| 1,120
2 – Alternate| 1,525| 1,455| 1,390| 1,330| 1,265| 1,190| 1,120| 1,045
1 – Low | 1,370| 1,300| 1,230| 1,150| 1,090| 1,000| 920| 860
NOTES
- To comply with government-mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
- Data is shown without a filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Individual cells shaded in grey indicate a temperature rise outside of the recommended range.
- To comply with government-mandated efficiency standards, speed settings shaded in grey are not allowed in HEAT mode.
- The denotes the factory COOL setting, denotes the factory HEAT setting, and denotes the factory FAN setting. If the Alternate speed is to be used, the speed tap must be adjusted at the blower motor plug.
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product that fails in normal use and service within the terms and conditions of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations are subject to change without notice and without incurring obligations. Printed in the U.S.A (09/2019) FRIGIDAIRE is a registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>