Alecto SA-100 Smoke Detector User Manual
- June 10, 2024
- Alecto
Table of Contents
SA-100 Smoke Detector User Manual
SA-100
SA-100 Smoke Detector
The SA-100 is a smoke detector set for discovery of fire in the first stage. If smoke develops, the SA-100 will give a loud beep of at least 85dB (A). As part of the link function all the smoke alarms within range will sound the alarm. We advice to test the smoke detectors weekly using the test button on the detectors. Save this manual in a safe place or inside of the electricity meter cupboard.
RECOMMENDED INSTALLATION LOCATIONS FOR THE SA-100:
-
Install the first smoke detector near the bedroom.
Ensure that it is placed so, if it would detect fire, at least one exit route would still be accessible. We recommend to place one alarm near each potential blockade of your exit route, so you are alerted before a fire would block off escape. -
Use multiple detectors to increase safety and ensure alert before the escape route is blocked.
-
Install at least one smoke detector on each floor of your house.
-
Install at least one smoke detector in each room where people smoke or where there is equipment that may potentially cause a fire.
-
Smoke and heat will first move upwards towards the ceiling; after that the smoke and heat will travel horizontally.
-
Install the detector on the ceiling. Except for rooms smaller than 1m, you should stay at least 50 cm away from the wall and 61cm from any corner. Smoke and heat do not gather in such corners, preventing the detector from alerting you on time.
IMPORTANT: For optimal operation, we recommend mounting the smoke detector on the ceiling. See also the installation instructions. If ceiling mounting is not possible, we recommend that you place the smoke detector in the middle of a wall. The installation location must be in the natural airflow of the room and free of side walls or slope.
DO NOT INSTALL IN THE FOLLOWING LOCATIONS:
- The kitchen; Steam from cooking might give a false alarm.
- The shower or bathroom; water damp might cause a false alarm and the moist environment might damage the detector.
- The garage: The car exhaust might cause a false alarm.
- In front of a fan or nearby the exhaust of an air conditioner or heater.
- In a ceiling nook.
- In rooms where the temperature could reach below -10°C or beyond 40°C.
- Do not paint or otherwise cover this smoke detector.
INSTALLATION INFORMATION:
Attach the ceiling plate using the included plugs and screws to the ceiling on
a location of choice. Wall mounting is not recommended for smoke detection.
Put the batteries in the detector. Then put the detector to the ceiling plate
and, twist clockwise to lock it in place. Perform a first test by holding the
test key for two seconds. Also see the paragraph: “Testing”.
USING, TESTING AND MAINTENANCE:
Using: The smoke detector works if the 3 x 3V lithium
batteries have been placed and/or the red strip is removed and the SA-100 is
mounted to the ceiling. The unit can only be mounted to the plate if the
batteries have been installed. The LED underneath the test button will now
flash ± every50 seconds. Once smoke is detected, the alarm will sound. Once
the smoke disappears, the smoke alarm will stop automatically
Test: Hold the test key for at least 2 seconds. The operation is still
correct if you hear two or three signal tones. Check the smoke detectors
weekly. In alarm status the smoke detector will generate about 85dB(A). Do not
use candles, open fire or cigarettes to test the smoke detector.
ATTENTION:
- If the cause of an alarm is unclear, assume it’s caused by fire. Immediately evacuate the building.
- Keep the smoke detectors out of range of children.
- Protect against dust during rennovations. Without protection the smoke detectors will lose their functionality. KEUKEN WOONKAMER GARAGE
Maintenance:
The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by vacuum.
PLAN AN ESCAPE ROUTE:
- Make a map and mark all locations of doors and windows and a possible escape route. Note that you may HOME-OFFICE need an escape ladder on high floors.
- Ensure everyone in the house knows the sound the smoke alarms produce and regularly practice use of the escape route.
- Leave the house immediately according to the plan when hearing the alarm. Every second counts: so respond quickly. If you do not notice smoke or heat, check if everyone in the house is in a secure location.
- Do not open any doors without feeling weather the door is warm or if there is smoke coming from underneath the doors. If it is, do not open that door. If the door is cold, put your shoulder firmly against the door and open it a small amount to check for any heat or smoke first.
- If there is much smoke, keep low and take shallow breaths, preferably through a moist towel. Call the fire department as soon as you are safe outside.
REPLACING THE BATTERIES:
The detector is supplied using 3 x 3V Lithium batteries.
Only use the recommended type Newsun CR-2450. Under normal conditions the
battery will last at least five years. If it is about to need replacement, the
smoke detector will make a chirping sound every 30 to 40 seconds. Pay
attention to the polarity when replacing batteries. Test the detector after
every battery replacement. If the smoke detector does not function, please
contact your supplier.
ENVIRONMENT:
Do not throw away used batteries, but recycle them using your local chemical
depot. Product may not be thrown out as normal waste, but must be recycled as
electrical waste.
Mounting type | Ceiling |
---|---|
Main power source | 3x Batteries, 3V Lithium, included. |
Autonomy | At least: 5 years |
Interconnectible device | No |
Suitable for installation in a recreational vehicle | No |
Individual alarm indicator | Yes |
Alarm prevention facility | No |
****18 1134 1134-CPR-210
DOP nr: SA-100_DOP_1
EN14604 : 2005 / AC: 2008 SA-100
Commaxx B.V., Wiebachstraat 37,
6466 NG Kerkrade,The Netherlands
Smoke Alarm Device SA-100
Fire detection in buildings
Essential characteristic 1: Pass
Essential characteristic 2: Pass
Essential characteristic 3: Pass
Essential characteristic 4: Pass
Essential characteristic 5: Pass
Essential characteristic 6: Pass
Essential characteristic 7: Pass
Essential characteristic 8: Pass
WWW.ALECTO.NL
SERVICE@ALECTO.NL
Commaxx B.V. Wiebachstraat 37
6466 NG, Kerkrade The Netherlands
Documents / Resources
|
Alecto SA-100 Smoke
Detector
[pdf] User Manual
SA-100 Smoke Detector, SA-100, Smoke Detector, Detector
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>