Excelitas AC9150-395 OmniCure LED UV Fiber Curing System User Guide
- June 10, 2024
- Excelitas
Table of Contents
- Excelitas AC9150-395 OmniCure LED UV Fiber Curing System
- Product Information
- Safety Precautions/ User Warnings
- Mounting the UV Head
- Connecting the UV LED Head
- Using the LED Head
- Getting Started **
- Troubleshooting
- Care and Maintenance
- **Technical Specifications
- **Regulatory Compliance
- **Warranty
- Contact Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Excelitas AC9150-395 OmniCure LED UV Fiber Curing System
Product Information
The UV LED Head is a device used for curing or drying various materials using
ultraviolet light. It is available in different models that vary in curing
width and part number. The applicable UV LED Head models are AC9150-395,
AC9150P-395, AC9225-395, AC9225P-395, AC9300-395, AC9300P-395, and
AC9225F-395. The curing width ranges from 150mm to 300mm depending on the
model. The part numbers for each model are 019-00241R, 019-00252R, 019-00255R,
019-00253R, 019-00247R, 019-00246R, and 019-00356R respectively.
Excelitas Canada Inc. located at 2260 Argentia Road Mississauga (ON) L5N 6H7
Canada manufactures the UV LED Head.
Safety Precautions/ User Warnings
Before using the UV LED Head, it is important to read and understand the safety precautions and user warnings outlined in the user manual. The glossary of symbols and safety precautions must be reviewed before installation and use.
Glossary of Symbols:
- Caution risk of danger – consult accompanying documents.
- Risk Group 3 (IEC62471)
- WARNING: UV emitted from this product. Avoid eye and skin exposure to unshielded product.
- CAUTION: Possibly hazardous optical radiation emitted from this product. Do not stare into operating lamp.
- Input/ Output Signals
- Input Signal
- Caution, Hot Surface
- Protective Conductor Terminal
- Earth (Ground) Terminal
- CAUTION, Risk of Electrical Shock
Safety Precautions:
This series of cautions and warnings relate to the installation, operation and
maintenance of the OmniCure® AC9- System. They are also presented throughout
this Installation/Reference Guide as applicable
WARNING
Do not stare directly at the light emitted from the LED array. This may be
harmful, resulting in eye injury. Always use UV protective eyewear as
indicated below. Additionally, protect any exposed skin with appropriate
clothing or shielding as required.
Warning UV protective eyewear must meet the following recommended optical
specifications:
- Spectral range; 350-440nm
- Optical Density ≥ 6
Warning Should the OmniCure® AC9- System be used in a manner not specified by
Excelitas Technologies, the protection provided by the equipment may be
impaired.
The UV LED Head operation can be affected if handled incorrectly. Never touch
the protective lens cover assembly of the UV LED Head. The presence of skin
oils may result in a decrease in system performance.
Always ensure the power supply unit is turned off prior to disconnecting or
re-connecting the UV LED Head.
Warning :
Monitoring the system during automated operation:
The level of UV energy supplied by the OmniCure® AC9- is sufficient to ignite
flammable substances. Therefore, when the unit is operated unattended in an
automated environment, an alarm function must be provided by the user to
indicate a malfunction in the associated equipment used. During installation
the appropriate measures must be included to prevent any such occurrence.
Optical Safety Data
IEC 62471: Photo biological Safety of Lamps and Lamp Systems Resulting Classification and Labelling
Hazard| AC9150/ P-395
AC9225/ P-395
AC9300/P-395
---|---
Actinic UV| Risk Group 3
Near UV| Risk Group 3
Blue Light| Risk Group 1
Retinal Thermal| Risk Group 2
Mounting the UV Head
Mount the UV LED Head in a location where it can be easily accessed and operated. Secure the head using the mounting brackets provided in the package.
**UV LED Head
**
WARNING
Do not block the air intake or the exhaust fans for the UV LED module’s
cooling system. Ensure that both intake and exhaust vents located on the LED
heads have at least 5 inches (12cm) of clearance to allow sufficient air flow.
The UV LED Head includes threaded mounting holes (on the front, on the back,
and on each side panel) M4 X 6mm deep. Mounting hole locations on the side
panel are identical for all AC9- models. However, front and back mounting hole
locations differ according to the model. Refer to Figure 2 above and
mechanical drawings for more information
(www.excelitas.com/omniure).
Never mount the system using only one row of mounting features or from one
side as this may damage the unit.
For applications requiring adjoining UV LED heads, mounting rails can be
constructed from two long L-brackets. Remember in adjoining-head applications
to remove the end-reflectors from all head-head abutment regions to maximize
head-head optical uniformity. The end-reflectors on the end-most points of the
optical line can remain in place to further extend uniform operating length
and operate as a UV shield for operators.
CAUTION
The threaded mounting holes in the AC9- incorporate a blind configuration;
ensure that the appropriate length of mounting hardware is used. Attempting to
install over-length mounting screws could damage the threaded mounting holes
and internal components.
Adjusting the Side Reflectors
To improve the longitudinal uniformity at the ends of the UV light line, the
AC9- series products are equipped with adjustable end reflectors (see Figure 2
). These reflectors can be lowered in 10mm increments and can provide about
15mm of extended useful length when fully extended to 30mm working distance.
They may also be useful in providing additional operator shielding of UV
light.
To gain best effect from this mechanical feature, ensure that in the intended
installation location the reflectors will not interfere with conveyed parts or
conveyor belt or other mechanical attachments. Failure to do so may result in
damage to ancillary hardware or the UV LED Head itself.
To adjust the reflectors:
- Ensure that power to the unit is switched off.
- Remove the two screws holding the end reflector in place.
- Move the reflector down to the desired position, insert and tighten the two retaining screws.
This operation can also be performed on a single head.
CAUTION
When the end reflectors are detached from the head, the ends of the optical
assembly and LED modules can be physically accessed. Take extreme care not to
allow fingers, tools or other foreign objects or debris to come into contact
with these areas. Doing so may severely damage or impair the function of your
AC9-series UV LED head. The installer should minimize the amount of time or
frequency that these regions of the LED head are left unprotected.
UV LED Head Dimensions
The dimensions and weights of the various AC9 Series models are outlined below:
| AC9150 / AC9150P| AC9225 / AC9225P/AC9225F| AC9300 /AC9300P
---|---|---|---
395 nm
Dimensions (LxWxH)| 159 x 80 x 218mm| 235 x 80 x 218mm| 311 x 80 x 218mm
Weight (kg)| 1.8| 2.7| 3.6
The mechanical drawings for each of the standard AC9 products are enclosed in
this manual, Note that print versions are 4mm shorter in height. For AC9
Series print version drawings or additional details or mechanical drawings for
other AC9 series models, please visit us online at
www.excelitas.com/omnicure.
For reference, the AC9300, AC9225 and AC9150 mechanicals can be found below.
Connecting the UV LED Head
Interfacing with the System Controller (PLC)
PLC Input Signal Requirements
| Digital| Analog
---|---|---
Input|
- Voltage: 0 – 24V
- Current: 1 – 40mA
|
- Voltage: 0 – 5V
- Current: 500uA
Output|
- Voltage: 0 – 5V
- Current: 2.5mA (max.)
|
PLC Connector Pin-Out
PIN | Name | Description |
---|---|---|
1 | Intensity Input | Input voltage is converted to required current to achieve |
desired intensity; intensity will vary linearly between 20% and 100% for
voltages between 1V and 5V respectively.
A minimum voltage of 0.4V is required for proper light source operation. If
the user inputs a voltage below the minimum required, the light source will
not turn on.
2| Enable High| 0.0V to +0.6V = Turns LEDs off (Open input will default to
OFF).
+2.4V to +24.0V = ON.
3| Enable Low| 0.0V to +0.6V = Turns LEDs on.
+2.4V to +24.0V = Turns LEDs off (Open input will default to OFF).
4| Thermal Fault| 0.0V to +0.4V (ground) = Fault
+2.4V to +5.0V (open) = No Fault
5| IsoDGND| Ground Reference for digital IOs
6| IsoVCC| +5.0V Output.
7| Reserved| Do not connect
8| Door Lock *| 0.0V to +0.6V = UV Emission Allowed.
+2.4V to +24V = UV Emission Stopped.
9| IsoGND| Ground Reference for analog IOs.
10| LED ON| 0.0V to +0.4V (ground) = LED off
+2.4V to +5.0V (open) = LED on.
11| Reserved| Do not connect
12| UV LED Fault| 0.0V to +0.4V (ground) = Fault
+2.4V to +5.0V (open) = No Fault
13| Reserved| Do not connect
PIN| Name| Description
14| Clear Fault/ LED Hours| High-to-low transition clears faults; low-to-high
transition initiates visual indicator sequence of accumulated LED hours
15| Temperature Monitor| Output is a voltage proportional to the maximum UV
LED heat sink temperature.
Conversion Factor: 0.05V/°C.
**Integrating Monitoring with External Circuitry
**
All inputs and outputs from the PLC interface are opto-isolated. The digital outputs are implemented using NPN logic.
Interfacing with the Power Cable
Please note that the 5 conductor DC power cable (018-00595R) must be used with
the AC9 series UV LED heads. The 3 conductor power cables (019-00559R) used
with other AC Series will not work with the AC9 Series.
Should third party cable assemblies be used, please note the following
specifications must be met in order to ensure reliable operation of the AC9
series UV LED heads and guarantee the appropriate EMI/EMC requirements are
met.
AC9300 /: 5 conductor 12AWG, shielded cable less than 5 meters in length.
AC9225 / AC9225P: 5 conductor 14AWG, shielded cable less than 5 meters in
length.
AC9150/ AC9150P: 5 conductor 16AWG, shielded cable less than 5 meters in
length or 3 conductor 12AWG, shielded cable less than 5 meters in length
(connect one of pins A1 or A2, one of pins A3 or A4, and A5). AC9225F: 5
conductor 14AWG, shielded cable less than 5 meters in length.
PIN | Name | Description |
---|---|---|
A1,A2 | +ve | 48V DC power feed |
A3,A4 | -ve | 48V DC power return |
A5 | Chassis | Chassis ground connection |
48V Input Requirements:
- Voltage: 46-50V DC
- Current: AC9150/P=23A; AC9225/P=34.5A;; AC9300/P=45.5A; AC9225F=26.3A
Note: For safety, the AC9 Series is internally fused. These fuses are not replaceable. If it is suspected that an internal fuse has blown, please contact Excelitas Technologies Service Centre for further assistance and refer to Sections 12 and 13 of this manual.
Using the LED Head
The peak wavelength of the UV LED Head is 395nm +/- 5nm, depending on model.
For all models, adjusting the UV LED Head intensity can be actuated by an
external controller via the PLC interface. Refer to Section 6 for Pin-Outs.
Input voltage vs. desired intensity; 5V = 100% and 1V = 20%. A minimum voltage
of 1V is required for light source operation.
Note: The light source will maintain a 20% intensity when the input voltage
is in the range of 0.5V. If the input voltage is below this, the light source
will turn off.
Ensure the UV LED Head indicator is illuminated to a steady green before
applying UV power to the head. The UV LED Head indicator will illuminate to a
steady amber indicating UV is on. When UV is off, the indicator will revert
back to a steady green indicating UV is off.
The UV LED Head is capable of responding to PLC control signals in less than
0.2 seconds.
Understanding the LED Indicators
LED Indicator | Condition |
---|---|
Steady green | System Ready; no critical faults |
Steady amber | UV LED turned ON |
Steady red | Critical fault |
- Temperature Fault
- LED Fault
- System Error
Slow flashing green (~1x/second)| POST and Initialization
Input voltage is less than 46V or greater than 50V. Unit is still functional.
Slow flashing red| Major and critical fault
Slow flashing amber| UV LED ON with 48V input voltage out of requirement
Fast flashing green (~3x/second)| Warranty status – operating hours is < 9,000
Fast flashing amber| Warranty status – operating hours = between 9,000 and
10,0000
Fast flashing red| Warranty status – operating hours is >10,000
A transition from high-to-low is required to clear the alarm signals. Use the PLC function:
Pin # | Description | I/O | Behavior |
---|---|---|---|
14 | Clear fault/ LED hours | In | 0V to 0.6V (Open) Logic Low |
2.4V to 24V Logic High
High-to-low transition = clear faults
Low-to-high transition = LED hours
Caution : Routine maintenance should only be completed by a user qualified personnel to avoid risk of injury to the end user. No user serviceable components are located within the power supply or UV LED Head enclosures.
Fault Status
PLC Output
- LED Fault: At least one module fails to turn on.
- Thermal Fault that includes:
- At least one module’s temperature is over the maximum limit.
- At least one module’s temperature is lower than the minimum limit or open circuit.
- Internal Fault.
Revision History
Revision # | Comments |
---|---|
Rev .0 | Initial release AC9 Series |
Rev.1.0 | Update LVD revision year and China RoHS section |
Rev. 2.0 | Addition of AC9225F |
Rev. 3.0 | Update to regulatory section |
Rev. 4.0 | Update to regulatory section |
Introduction
The OmniCure® AC9-series-series represents a new standard in UV LED curing
systems. The series provides unsurpassed levels of power, irradiance
performance, control and monitoring in a compact form factor. The OmniCure®
AC9-series systems are offered alongside a variety of power supply, controller
and cabling options, providing configuration flexibility to suit any
application for end users and integrators alike.
Optical output is controlled via a PLC interface enabling a high degree of
automation. At the heart of the OmniCure® AC9-series are the arrays of LEDs
housed within the UV LED Head and located under the optical lens providing
excellent spectral and power stability. The UV LED Head has a typical lifetime
in excess of 20,000 hours of accumulated ‘on’ time, made possible by the
integration of state-of-the-art electronics, effective thermal management and
high performance optics. Acoustic noise is minimized through an innovative
load-adaptive fan that keeps the LEDs operating efficiently and reliably while
minimizing the resultant noise levels.
In the OmniCure® family of UV LED light systems, all systems offer the same
high level of innovation, quality and reliability that our customers have come
to expect. Since 1984, OmniCure® has combined next generation optical
engineering, state-of-the art electronics and fiber-optics to produce
sophisticated technologies that employ light. Today, OmniCure® is a leading
developer of light-based systems for sectors ranging from manufacturing to
bio-medicine, and is unmatched in our commitment to quality and service.
This manual covers the following models:
Model | Array Curing Width | Part Number |
---|---|---|
AC9150-395 | 150 mm | 019-00241R |
AC9150P-395 | 150mm | 019-00252R |
AC9225-395 | 225 mm | 019-00255R |
AC9225P-395 | 225 mm | 019-00253R |
AC9300-395 | 300 mm | 019-00247R |
AC9300P-395 | 300 mm | 019-00246R |
AC9225F-395 | 225mm | 019-00356R |
Excelitas Technologies recommends reading this guide to discover all features of the OmniCure® AC9-Series systems, and how to use them.
Getting Started **
**
Packaging Contents
The package contains one of the following UV LED Heads, as well as a quick start reference guide:
Model | Array Curing Width | Part Number |
---|---|---|
AC9150-395nm | 150 mm | 019-00241R |
AC9150P-395nm | 150 mm | 019-00252R |
AC9225-395nm | 225 mm | 019-00255R |
AC9225P -395nm | 225 mm | 019-00253R |
AC9300-395nm | 300 mm | 019-00247R |
AC9300P-395nm | 300 mm | 019-00246R |
AC9225F-395nm | 225mm | 019-00356R |
Replacement air filters (qty: 10) can be ordered from Excelitas Technologies. Carefully unpack the unit and store the packing material for future use.
System Requirements
In addition to the UV LED Head, the following components are required:
- Power supply
- Power cable
Note: You will also require a PLC controller unless you are using an
existing controller. The PLC controller is used to discover the extensive
functionality of the UV LED Head, but integrators can access the full feature
set through integrating with the PLC interface directly. Refer to Section 6.1.
These components may be sourced separately or may be purchased from Excelitas
Technologies. Check with Excelitas Technologies to determine the appropriate
components for your requirements. The following table provides the part
numbers of recommended component parts.
Standard | AC9150 – 395nm | AC9225 -395nm | AC9300-395nm |
---|---|---|---|
UV Head | 019-00241R | 019-00255R | 019-00247R |
System Controller | 019-00211R | 019-00211R | 019-00213R |
DC Power Cable | 018-00595R | 018-00595R | 018-00595R |
PLC2000 controller1 | 019-00214R | 019-00214R | 019-00214R |
AC9150P – 395nm | AC9225P-395nm | AC9300P-395nm | |
UV Head | 019-00252R | 019-00253R | 019-00246R |
System Controller | 019-00211R | 019-00211R | 019-00213R |
DC Power Cable | 018-00595R | 018-00595R | 018-00595R |
PLC2000 controller1 | 019-00214R | 019-00214R | 019-00214R |
Optical Fiber | AC9225F -395nm | ||
UV Head | 019-00356R | ||
System Controller | 019-00211R | ||
DC Power Cable | 018-00595R | ||
PLC2000 controller | 019-00214R |
Connecting the Power Supply and PLC Controller
Note : All connectors are via screw style fastener — do not over
tighten the connector screws.
Note : The following is a generic procedure, illustrated with the
common components described above; please refer to specific documentation
related to your power supply and controller.
Tip : After securing the power cable to the power supply, it is
recommended to “tie-off” the female connector cable on to the mounting
brackets or process rigging as a form of strain relief.
- Make sure the power supply unit is turned off.
- Connect the AC power cord to the power supply.
- Attach the male end of the power cable to the power supply unit, and connect the female end of the power cable to the UV LED Head.
- Connect the PLC loop-back connector to the PLC pass-through port
- Power up the UV LED Head per Section 4.4, and then push the LED Enable button on the controller to turn power on to the LED Head.
- Adjust intensity using the up or down buttons to the right of the display to increase and decrease the intensity respectively. , “Using the LED Head”.
- UV LED & Temperature faults will be indicated by an illuminated LED on the control console. To clear, press the Clear Fault button .
Powering Up and Powering Down
- Ensure that the AC9- system has been properly installed and the UV LED Head is securely mounted with the optical lens in the desired orientation. Refer to Section 5, “Mounting the UV Head”.
- Verify that the power supply unit’s AC supply cord is connected to a properly grounded AC outlet.
- If the power supply has a circuit breaker, switch it to the “ON” position.
- Turn the main power switch of the power supply to the “ON” position and check the fan for airflow.
- The LED indicator on the UV LED Head will flash green during “boot-up” and change to a steady green indicating UV LED Head is ready for use. It is recommended to wait for 15 seconds from initial power-up before attempting to control the UV head. For more information about the indicators, see Section 7.1, “Understanding the LED Indicators”.
After turning on UV power, the system will reach a fully stable operating
temperature in 2-3 minutes. Caution – the UV LED Head can become very hot,
avoid handling until the UV LED Head has cooled down (approx. 5 min) or use
protective gloves.
Before disconnecting any cables, power down the UV LED Head using the PLC
controller and turn off the power supply. (Note: the cooling fan may take up
to 10 seconds to stop).
Troubleshooting
Symptoms and Possible Causes
Service to be completed by qualified Excelitas Technologies personnel only!
Always wear optical safety glasses while troubleshooting. Never put hands or
fingers in front of the lens. Serious personal injury may result.
Do not place any potentially combustible materials (e.g. paper, card, etc.) in
front of the LED Head. Risk of fire and damage to the UV LED Head may result.
If the system fails to power up:
- Make sure the AC power cord is securely plugged into a functional AC outlet and into the AC inlet on the power supply unit.
- Make sure that the circuit breaker on the power supply unit is not tripped. If so, reset breaker.
- Make sure all cable connections (power supply to UV LED Head) are secure.
- Ensure that the power supply is switched on and the green LED indicator on the front panel is lit.
- Make sure the door lock electrical loopback on the PLC is installed properly.
If the system powers up but experiences a thermal fault during operation:
- Ensure UV Head is installed with adequate clearance around intake and exhaust ports.
- Ensure intake air filter is not clogged or obstructed.
- If filter is clogged, either clean with compressed air or replace with a new filter insert.
If the system powers up but does not emit UV:
- Check that the door lock loop is intact.
- Ensure that the voltage levels on pins 2 and 3 of the PLC interface match the logic required to enable the LEDs.
- Check the visual indicator for signs of a fault.
If a fault condition has been detected:
- Attempt to clear the fault by toggling the voltage high on pin 14 of the PLC interface or by pressing the “Clear Fault” button on the PLC controller.
If the system exhibits a fault condition with a slow-flashing red:
- Power-cycle the UV Head to clear.
If the light intensity is too low:
- Make sure the input voltage is at least 46V (input voltage to the Head for the purposes of powering the head is typically 48V (46-50V DC)).
- Out-of-range input voltage will be indicated on the visible indicator on the UV LED Head with a slow flashing green.
- Clean the optical window of the UV LED Head as described in Section 9.3, “Cleaning the LED Head”.
- Verify that the intensity level of the UV LED Head is set to the correct level, using the PLC Controller.
If problems persist beyond these troubleshooting points, please contact Excelitas Technologies Service Department (refer to Section 13, “Contact Information”).
Care and Maintenance
Note : Excelitas Technologies recommends incorporating the cleaning of the optical lens into the user/operator cleaning and maintenance schedule.
Cautions and Handling
Caution: Routine maintenance should only be completed by qualified
personnel to avoid risk of injury/electrical shock to the end user. No user
serviceable components are located within the UV LED Head enclosure.
Warning : Use UV radiation eye and skin protection during servicing if
access to the UV LED modules is required during operation.
Risk Group 3 (IEC62471)
WARNING : UV emitted from this product. Avoid eye and skin exposure to
unshielded product.
CAUTION : Possibly hazardous optical radiation emitted from this product.
Do not stare into operating lamp.
CAUTION UV : Hazardous visible radiation is emitted from this
product. Eye or skin irritation may result from exposure. Use appropriate
shielding.
Ensure main power supply is disconnected prior to making any changes to
cabling configurations.
Ensure that both intake and exhaust vents located on the LED heads have at
least 5 inches (12cm) of clearance to allow sufficient air flow.
Avoid physical shocks or jarring of the LED Head, especially while the unit is
operating.
When necessary, clean the optical lens of the UV LED Head using an optical
cleaning solution. Refer to Section 9.3, “Cleaning the LED Head”.
The UV LED Head includes an optical lens assembly. Improper handling and
cleaning practices can damage polished surfaces or coatings which are utilized
in this optical lens. Note that damage to the surface of the glass or coating
can degrade the unit’s performance. Proper handling and cleaning technique is
very important. Below are the recommended procedures for cleaning of the
OmniCure® UV LED Head optical lens.
Always handle the UV LED Head by the metal enclosure; never touch the optical
lens with your fingertips. The moisture or oils on your fingertips can damage
the coating of the lens. Fingerprints left on an optical surface for an
extended period of time, can become a permanent stain. Even if you are wearing
gloves, avoid touching the optical surface.
Never touch the optical lens with metal implements or tweezers.
Do not place the UV LED Heads lens assembly down onto a hard tabletop surface;
this can cause scratches in the lens surface.
To store UV LED Heads, wrap them individually in a clean, lint free bag and
store in a safe place, preferably using the original packaging.
Never store unwrapped LED Heads together in a box or bag, as they may become
damaged if they come in contact with each other.
Cleaning Materials
- Lint-free lens tissue, lint-free cotton swabs, lint or powder-free gloves or finger cots.
- An organic solvent, such as reagent-grade isopropyl alcohol, reagent-grade acetone, or lens cleaning solution.
Cleaning the LED Head
WARNING
Do not attempt to open the enclosure of the LED head. Ensure power to the
power supply unit is OFF and the UV LED arrays are cool before attempting any
cleaning procedure.
Use protective gloves or finger cots suitable for the cleaning solution
selected. Refer to the MSDS for guidance.
Turn off the UV LED Head and keep the optical lens, face down to prevent the
solvent from seeping into the assembly during the cleaning procedure.
Blow off dirt and dust with pressurized air on front glass surface.
Use a lens tissue folded into quarters or a lint-free cotton swab. Saturate
the lens tissue or swab with organic solvent as indicated in the cleaning
materials section.
**CAUTION
Before using any solvent, consult the manufacturer’s Materials Safety Data
Sheets (MSDS) and your internal Health and Safety Advisor for proper handling
and storage.
Using a new saturated tissue; clean optical lens by gently wiping the surface
with a continuous stroke in one direction.
Note: Never apply a dirty tissue or swab to the optical lens of the UV
LED Head.
Note : Never face the optical lens upwards before the solvent has
evaporated.
Cleaning the LED Head Air Intake
CAUTION
**Ensure that the LED Head power cable is disconnected from the head assembly
and the UV LED Head is cool to the touch.
The air intake filter is located on the exterior of the LED Head (Figure 2)
and is removable for cleaning and/or replacement as required. Remove the
filter frame by gently prying the frame from the clip end. Next, remove the
filter media located within and clean with compressed air.
Replace the filter guard and frame prior to powering up the LED Head.
**Technical Specifications
**
Environmental Conditions
Operating Conditions
Ambient Temperature| 15ºC to 40ºC 1
Altitude:| 3000m max.
Atmospheric Pressure:| 700 to 1060 hPa
Relative Humidity:| 10% to 80% (non-condensing)
Installation Category| II
Pollution Degree| 2
Transport and Storage Conditions
Temperature| -20 to +75ºC
Relative Humidity| 0% to 80% (non-condensing)
Atmospheric Pressure| 500 to 1060 hPa
UV LED Head Specifications
Specification | AC9150 / AC9150P | AC9225 / AC9225P/AC9225F | AC9300 / AC9300P |
---|---|---|---|
Part number | 019-00241R | 019-00252R | 019-00255R |
019-00247R | 019-00246R | ||
LED Peak Wavelength | 395nm | ||
Estimated LED Life | >20,000 hrs | >40,000 hrs | |
Maximum Peak Irradiance | 14W/cm2 | 20W/cm2 | 14W/cm2 |
Variable Intensity Range | 20 – 100% | ||
Typical Working Distances | 1-30mm | 1-5mm | 1-30mm |
1-5mm
Active Optical Area| 25 x 150mm| 25 x 225mm| 15×225| 25x300mm
Longitudinal Uniformity| Better than +/- 10%
Operating Voltage| 48V DC +/-2V
Maximum Operating Current| 23A| 34.5A| 26.3A| 45.5A
**Regulatory Compliance
**
Product Safety and Electromagnetic Compatibility
The OmniCure AC9 Series has been tested and found to comply with product
safety and electromagnetic compatibility requirements. For a complete list of
tests and for certification details, please contact your OmniCure
representative.
CE Marking:
Council Directive 2014/35/EU| Low Voltage|
---|---|---
Council Directive 2014/30/EC| EMC
Council Directive 2012/19/EU| WEEE
Council Directive 2011/65/EU as amended by (EU) 2015/863| RoHS
This is a class A product. In a domestic environment, this product may cause
radio interference in which case the user may be required to take adequate
measures.
FCC Class A Digital Device or Peripheral – Information to User
Note : This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at their own expense.
**WARNING
Changes or modifications not expressly approved by Excelitas Technologies
could void the user’s authority to operate the equipment.
China RoHS**
The symbol above indicates that this product is in compliance with China RoHS
requirements.
| Part Name| Hazardous Substances
---|---|---
| Lead (Pb)| Mercury (Hg)| Cadmium (Cd)| Hexavalent Chromium (Cr (VI))|
Polybrominated biphenyls (PBB)| Polybrominated diphenyl ethers (PBDE)|
Printed Circuit Board Assemblies| X| O| O| O| O| O|
| | | | | | | | |
This table is compiled according to SJ/T 11364.
O : Indicates that the content of the hazardous substance in all homogeneous
materials of the part is below the limit requirement of GB/T 26572.
X : Indicates that the content of the hazardous substance in at least one of
the homogeneous materials of the part exceeds the limit requirement specified
by GB/T 26572.
WEEE Directive
The symbol above indicates that this product should not be disposed of
along with municipal waste, that the product should be collected separately,
and that a separate collection system exists for all products that contain
this symbol within member states of the European Union.
The equipment that you bought has required the extraction and use of natural
resources for its production. It may contain hazardous substances that could
impact health and the environment.
In order to avoid the dissemination of those substances in our environment and
to diminish the pressure on the natural resources, we encourage you to use the
appropriate take-back systems. Those systems will reuse or recycle most of the
materials of your end life equipment in a sound way.
The crossed-out wheeled bin symbol indicated above invites you to use those
systems.
If you need more information on the collection, reuse and recycling systems,
please contact your local or regional waste administration
Accessories
Various accessories to enhance the application utility of the AC9-series are
available. Please contact Excelitas Technologies for more information.
**Warranty
**
Excelitas Technologies warrants the original purchaser for a period of one (1)
full year, calculated from the date of purchase, that the equipment sold is
free from defects in material and workmanship.
In the event of a claim under this warranty, the equipment is to be sent
postage and carriage paid to the Excelitas Technologies Service Centre.
Returned equipment will not be received without a Return Authorization (RA)
Number, issued by the appropriate Service Centre.
In order for us to serve you better, include a written description of the
fault and the name and telephone number of a contact person who may be
contacted for additional service related questions.
Any claims for units received with defects in material or workmanship must be
reported to an authorized Excelitas Technologies Service Centre within 30 days
from the original date of receipt and returned within 30 days of reporting to
a an authorized Excelitas Technologies Service Centre. Excelitas Technologies
will repair or replace these reported defects free of charge. The equipment
must be sent postage and carriage paid.
Package the equipment in its original shipping case or as appropriate to
prevent damage during transport.
In the case of damage caused by wear and tear, careless handling, neglect, by
the use of force or in the case of interventions and repairs not carried out
by an Excelitas Technologies Authorized Service Centre, the warranty ceases to
be valid. This warranty may not form the basis for any claims for damages, in
particular not for compensation of consequential damages.
This warranty is not transferable.
No warranty is extended to perishable items (if purchased separately or
included in systems). These may include, but are not limited to air filters
and cables.
WARNING
Apart from filters there are no field serviceable parts within the equipment.
Opening the equipment main enclosure will void the warranty.
Checking Your Lamp Hours
Level transitions on pin 14 of the PLC interface can be used to access the UV
LED warranty status information:
Pin # | Description | I/O | Behaviour |
---|---|---|---|
14 | Clear fault/ LED hours | In | 0V to 0.6V (Open) Logic Low |
2.4V to 24V Logic High
Low-to-High transition = LED hours
You can also check the status by pressing the Clear Fault button on the PLC
Controller: on release of the button, the warranty status is indicated on the
status indicator on the UV LED Head.
The LED indicator on the UV Head will display the warranty status of the UV
LEDs as follows:
LED Indicator | Condition |
---|---|
Fast Flashing Green | Operating hours is < 9000 |
Fast Flashing Amber | Operating hours = between 9,000 and 10,0000 |
Fast Flashing Red | Operating hours is >10000 |
Replacement UV LED Module Warranty
If the AC9- system fails to power up during the warranty period of 10,000
operational hours or 2 years, whichever comes first, the UV LED Module will be
replaced under warranty. In the event of a claim under this guarantee, the UV
LED Head is to be sent postage and carriage paid, including a description of
the fault, to the nearest appropriate Excelitas Technologies Service Centre.
Returned equipment will not be received without a Return Authorization (RA)
Number, issued by the Service Centre. This warranty is non-transferable.
In the case of damage caused by careless handling, neglect, by the use of
force or in the case of interventions and repairs not carried out by an
Excelitas Technologies Service Centre to the AC9- system, the guarantee ceases
to be valid.
Returning your AC9- System to Excelitas Technologies for Service
Please make a note of the problem encountered, the steps followed to isolate
the problem and the result of any trouble shooting steps taken.
Telephone the nearest Excelitas Technologies Service Centre to obtain a Return
Authorization Number so that repairs may be completed quickly and efficiently.
In North America, request for Return Authorization number can be made online
at https://www.excelitas.com/ox_service_request_form
Enclose details of the problem with the unit and return both to the Excelitas
Technologies Service Centre. The unit should be returned in its original
packaging if possible.
Include a phone number and contact person who may be reached for any
additional service-related questions.
Contact Information
Excelitas Canada Inc. 2260 Argentia Road Mississauga, Ontario L5N 6H7 CANADA
Tel.: +1 905 821-2600
Toll: +1 800 668-8752 (USA and Canada)
Fax: +1 905 821-2055
http://www.excelitas.com/Pages/Contact/Contact_OX.aspx
http://www.excelitas.com/omnicure
Technical Assistance:
Techsupport@excelitas.com
https://www.excelitas.com/ox_service_request_form
For a complete listing of Authorized OmniCure Distributors and Service Centers
please go to https://www.excelitas.com/dealer-
search
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>