ELKAY NFC3 Drinking Water Cooler and Bottle Filler User Manual
- June 15, 2024
- ELKAY
Table of Contents
- ELKAY NFC3 Drinking Water Cooler and Bottle Filler
- Product Information
- Product Usage Instructions
- Sub Menu 2
- Service Instructions
- Cleaning
- Temperature Control
- Stream Height Adjustment
- Register in plumb SMART
- FCC COMPLIANCE STATEMENT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELKAY NFC3 Drinking Water Cooler and Bottle Filler
Product Information
Specifications
- Model: LZSTL8WSSP-W1
- Basin: 11
- Water Inlet: 3/8
- Filter Assy: 51300C – 3000 Gal.
- Filter Head Fittings Kit: 1000005214 – includes John Guest Fittings & 3/8 Elbow, Filter Bracket/Screws
- NFC Board/Cover Kit: 1000004409
Product Usage Instructions
Lower and Upper Shroud
To access the refrigeration system and plumbing connections, follow these
steps:
- Remove two (2) screws from the front of the cooler to remove the lower shroud.
- To remove the upper shroud for access to the pushbars, regulator, solenoid valve, or other components located in the top of the unit, do the following:
- Remove the lower shroud.
- Disconnect the drain.
- Remove four screws from tabs along the lower edge of the upper shroud.
- Unplug two wires and water tube.
Bubbler
To remove the bubbler, follow these steps:
- Disconnect the power supply.
- Reach the underside of the bubbler through the access panel on the underside of the upper shroud.
- Remove the access panel by removing the retaining screw.
- To remove the bubbler, loosen the locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in the General Instructions.
- After servicing, replace the access panel and retaining screw.
Switches Behind the Push Bar
- The regulator in an EZ cooler is always held fully open by the use of a single regulator nut. Water is not dispensed until the pushbar is depressed to activate a switch which then opens a solenoid valve.
- To remove sidebars, from the inside compress the flared tabs and pull out carefully. To reinstall side pushbars, insert the front of the pushbar first. While keeping the switch depressed, snap the rear of the pushbar into position.
Cleaning
- Clean stainless steel components with a uniform finish pattern.
- Clean plastic components according to their properties.
Programming Instruction
- To activate the main menu, depress the button for 3 seconds and then release. The menu will cycle through main menu items for 2 seconds each for 2 cycles and then exit unless selected. It will also cycle through sub menu items for 2 seconds each for 2 cycles and then return to the main menu unless selected. Selections are saved when the menu is exited.
Main Menu
- Momentary: Scrolls through all the settings on unit
- Momentary: Flashes error code
- Momentary: Sets time
- Momentary: Sets filter status and errors
Sub Menu 1
- Momentary: Sets day (Sunday-Saturday)
- Momentary: Sets AM/PM
- Momentary: Sets hour (12 hour)
- Momentary: Sets filter
- Momentary: Sets minute (0-69 in 5 minute increments)
Sub Menu 2
- Momentary: Turns off filter status and errors
- Momentary: Default setting – Turns on filter status and errors
Refrig Range
FAQ
-
Q: How do I remove the lower and upper shrouds?
A: To remove the lower shroud, remove the two screws from the front of the cooler. To remove the upper shroud, first remove the lower shroud, then disconnect the drain, remove four screws from tabs along the lower edge of the upper shroud, unplug two wires and water tube. -
Q: How do I remove the bubbler?
A: To remove the bubbler, first disconnect the power supply. Then reach the underside of the bubbler through the access panel on the underside of the upper shroud. Remove the access panel by removing the retaining screw. Loosen the locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in the General Instructions. After servicing, replace the access panel and retaining screw. -
Q: How do I clean the product?
A: Clean stainless steel components with a uniform finish pattern. Clean plastic components according to their properties.
NOTE:
When installing replacement bubbler and pedestal, tighten nut only to hold
parts snug in position. Do Not Overtighten
WATERSENTRY ® **** FILTER PARTS LIST
ITEM NO.| PART NO.| DESCRIPTION
1| 51300C| Filter Assy – 3000 Gal.
2| 1000005214|
- Kit – Filter Head Fittings includes
- John Guest Fittings & 3/8” Elbow
3| 1000004409| Filter Bracket/Screws Kit – NFC Board/Cover
Service Instructions
Lower and Upper Shroud
To access the refrigeration system and plumbing connections, remove two (2)
screws from front of cooler to remove the lower shroud. To remove the upper
shroud for access to the pushbars, regulator, solenoid valve or other
components located in the top of the unit, remove lower shroud, disconnect
drain, remove four screws from tabs along lower edge of upper shroud, unplug
two wires and water tube.
Bubbler
To remove the bubbler, first disconnect the power supply. The underside of the
bubbler can be reached through the access panel on the underside of the upper
shroud. Remove the access panel by removing the retaining screw. To remove the
bubbler, loosen locknut from the underside of the bubbler and remove the
tubing from the quick connect fitting per the Operation Of Quick Connect
Fittings section in the General Instructions. After servicing, replace the
access panel and retaining screw.
Switches Behind the Push Bar
- The regulator in an EZ cooler is always held fully open by the use of a single regulator nut. Water is not dispensed until the pushbar is depressed to activate a switch which then opens a solenoid valve.
- To remove sidebars, from the inside compress the flared tabs and pull out carefully. To reinstall side pushbars, the front of the pushbar is inserted first. While keeping the switch depressed, snap the rear of the pushbar into position.
Cleaning
- Stainless Steel
- General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
- Steel soap pads should never be used; particles can adhere to a stainless steel basin surface and will eventually rust.
- Light scratches are normal for stainless steel basins; over time they will blend into the uniform finish pattern.
- Plastic Components
- General cleanin g: use an ordinary mild detergent and soft cloth, rinse and towel dry. Wiping the surface clean to remove debris or build up will not hurt the antimicrobial properties.
Temperature Control
- Factory set at 50°F (+/- 5°F) under normal conditions. For temperature adjustments, refer to sticker on left side of top bar.
Stream Height Adjustment
VIEW OF UNDERSIDE OF BASIN SHROUD
LZSTL8WSSP-W1
Programming Instruction
Depress Button for 3 seconds to activate main menu – release
Cycles thru main menu items 2 seconds each for 2 cycles then exits menu unless
selected
Cycles thru sub menu items 2 seconds each for 2 cycles then returns to main
menu unless selected
Selections are saved when the menu is exited
Top **leve l| Action| Sub Menu 1|
Action| Sub Menu/action| Action| Sub Menu/ action|
Action| Sub Menu/ action| Notes| End Action**
Info| Momentary| Scrolls through all the settings on unit| | | | | | | |
Returns to Main Menu
Info| Momentary| Flashes error code| | | | | | | | Returns to Main Menu
Set time| Momentary| | | | | | | | | Drops to next level when selected
| Day (Sunday-Saturday| Momentary| | | | | | Use push button to select the day
on the display| Drops to next level when selected
| AM/PM| Momentary| | | | | | Use push button to select AM or PM| Drops to
next level when selected
| Hour (12 hour)| Momentary| | | | | | Use push button to select Hour| Drops
to next level when selected
| Min 0-69 in 5 minute increments| Momentary| | | | | | Use push button to
select closest minute| Returns to Main Menu
Filter| Momentary| | | | | | | | | Drops to next level when selected
| No| Momentary| Turn off filter status and erros| | | | | No Filter unit –
Error codes related to filter status turned off| Returns to Main Menu
| Yes| Momentary| Default setting – Turn on filter status and errors| | | | |
Filter status has default ON / Default has read write to filter, LED status
display, filter error capability| Returns to Main Menu
Refrig| Momentary| | | | | | | | | Drops to next level when selected
| No| Momentary| Turns off power to E/S relay sets bottle fill time to 1.5gpm|
| | | | Refrigeration off| Returns to Main Menu
| Yes| Momentary| Default setting – Turns on power to E/S relay – sets time to
1.1gpm| | | | | Refrigeration on| Returns to Main Menu
Range| Momentary| | | | | | | | The lower the number, the closer to the sensor
the bottle needs to be to activate| Drops to next level when selected
| 1-10| Momentary| Default setting 5 – Adjusts distance from sensor the bottle
needs to be before turning before turning on or off the bottle filler| | | | |
| Returns to Main Menu
B-Light| Momentary| | | | | | | | The settings are for the brightness of the
display and night light| Drops to next level when selected
| 25%| Momentary| | | | | | | Returns to Main Menu
| 50%| Momentary| | | | | | | Returns to Main Menu
| 75%| Momentary| Default Setting| | | | | | Returns to Main Menu
| 100%| Momentary| | | | | | | Returns to Main Menu
Ener Save| Momentary| | | | | | | | | Drops to next level when selected
| Off| Momentary| Default Setting| | | | | | Returns to Main Menu
| On| Momentary| Set Energy Save Schedule| | | | | | Drops to next level when
selected
| | | | | Select Weekday| | | | Drops to next level when selected
| | | | | | Momentary| Select time on| 24 hours – 1-12AM and 1-12PM| Drops to
next level when selected
| | | | | | Momentary| Select time off| 24 hours – 1-12AM and 1-12PM| Drops to
next level when selected
| | | | | Select Week- end| | | | Drops to next level when selected
| | | | | | Momentary| Select time on| 24 hours – 1-12AM and 1-12PM| Drops to
next level when selected
| | | | | | Momentary| Select time off| 24 hours – 1-12AM and 1-12PM| Returns
to Main Menu
Pictured is unit only without bottle filler.
Note: Danger! Electrical shock hazard. Disconnect power before servicing
unit.
Uses HFC-134A refrigerant
ATTENTION:
If the product serial number is before 190424189, please refer to archived
documents section of Elkay.com for the most accurate parts
list. (www.elkay.com/archived-documents)
115V PARTS LIST
ITEM NO.| PART NO.| DESCRIPTION|
1| 28401C| Hanger Bracket|
2A| 55001109| Basin – Stainless Steel|
2B| 0000001337| Basin – Bottle Filler Stainless Steel|
3| 36216C| Wiring – Front/Side Push Bar|
*4| 36322C| Compr – Service Pak 115V EMIS70HHR|
5| 56092C| Tube – Poly (Cut To Length)|
6| 56229C| Assy – Shroud – Upper (Front Side Push)|
7| 66703C| Drier|
8| 56213C| Access Panel|
9| 1000004572| Kit – Solenoid Valve/Regulator Assembly|
10| 1000004564| Kit – Regulator W/Holder & Nut|
11| 56073C| Replacement Bubbler Assy|
12| 98734C| Kit – Pushbar (Front/Side) TL|
13| 1000001600| Kit – Pushbar (Front Only)|
14| 35980C| Power Cord Non-Refrigerated|
15| 1000004568| Power Cord – EZTL8|
16| 98775C| Kit – Fan Motor/Blade/Screws/Nut|
17| 98776C| Kit – Condenser/Drier/WireTies|
18| 98777C| Kit – Compr Mtg Hdwe/Grommets/|
| | Clips/Studs|
19| 98778C| Kit – Heatx/Drier|
20| 98898C| Kit – Hardware|
21| 0000000238| Kit – 115V Electricals (Relay, Ovrld, Cover)|
22| 98724C| Kit – Evap. Replacement|
23| 1000001602| Kit – 75583C Elbow 5/16″ x 1/4″ (3 Pack)|
24| 1000004547| Harness – Cooler|
25| 1000004550| Wire – 6” Jumper|
26| 1000004559| Wire Assy – Jumper|
27| 1000004447| Wasteline Drain Assy|
28A| 98900C| Kit – Drain Replace TL|
28B| 97969C| Kit – Drain Replace (TL) LR|
29| 1000001812| Kit – Bottle Filler Drain|
30| 98773C| Kit – Cold Control|
NS| 2000001220| Kit – Panel (Wrapper) Stainless TL|
| 2000001210| Kit – Panel (Wrapper) Stainless LZTLD|
NS| 28024C| Filler – Wrapper Light Grey LZTLD|
| 28025C| Filler – Wrapper Stainless LZTLD|
NS| 1000001892| Bracket – Trim Strip Light Grey LZTLD|
| 1000001891| Bracket – Trim Strip Stainless LZTLD|
NS| 1000001894| Panel – Universal Trim Light Grey LZTLD|
| 1000001893| Panel – Universal Trim Stainless LZTLD|
NS = Not Shown NS = No semuestra|
- INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
- NOTE: All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.
|
ITEM NO.| PART NO.| DESCRIPTION|
NS| 98546C| Kit – Aerator Replacement|
31| 98549C| Kit – Hardware & Waterway (BF)|
32| 1000004573| Kit – Solenoid Valve 120V (BF)|
NS| 1000005077| Nameplate – Elkay Filtered|
33| 1000002433| Kit – Top Cover Assy (BF)|
34| 1000005219| Kit – IR Sensor K+|
35| 2000000832| Kit – Connected Ready Control Board|
NS| 1000004436| Kit – Tower/Basin Gasket|
36| 1000004546| Harness – Bottle Filler|
37| 1000004549| Harness – LED/IR Board|
38| 2000001084| End-point Board|
39
40
|
- 2000001085
- 2000001086
| Harness – End-point Board Bracket, End-point Board Mounting|
Register in plumb SMART
- Install Zorn Gateway per the Gateway Instructions Manual (Required & Sold Separately)
- Request plumbSMART Administrator Account at 844-987-6737
- Zorn creates your Enterprise Account for you! (You will be required to identify your building location, number of floors, and number of rooms.)
- Log in to plumbsmart.zurn.com
- Register each Connected Product in plumbSMART (Watch How-To Videos to Get Started. Located in the support section inside the portal.)
Note: Refer PlumbSMART Registration ID Label provided with Connected Product 6. Now, Relax. You’re Connected.
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved could void your
authority to use this equipment
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
- If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device shall be used in such a manner that the potential for human contact
normal operation is minimized. This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with a minimum distance of 20cm between the
radiator and your body. This device and its antenna(s) must not be co-located
or operating in conjunction with any other antenna or transmitter.
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
- The device shall be used in such a manner that the potential for human contact normal operation is minimized. This equipment complies with RSS-102 radiation exposure limits.
- This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.
ELKAY MANUFACTURING Co.
- 1333 BUTTERFLIED ROAD SUITE 200 DOWNERS GROVE, IL 60515 USA –
- 630.574.8484
- www.elkay.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>