Hunter 13055 Donelson 5 Light Linear Chandelier Owner’s Manual

June 9, 2024
Hunter

Hunter 13055 Donelson 5 Light Linear Chandelier

Hunter-13055-Donelson-5-Light-Linear-Chandelier-
product

WARNING

  • To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
  • The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
  • All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.

READ AND SAVE THESE INSTRUCTIONS
These instructions are provided for your safety. It is very important that they are read carefully andcompletely before beginning installation of the lighting fixture.

Tools

Here are the tools you’ll need to complete your installation:

  • Ladder
  • Screwdriver
  • Pliers
  • Wire Strippers
  • Drill

Specification

  • Fixture weight ±2 lbs: 18.4 lbs (8.34 kg)

Hardware Service Kit

  • Part
    • KG22101L08
    • KG22101872
  • Model
    • 13054
    • 13055
  • Finish
    • Rustic Iron
    • Natural Iron

PREPARING FOR INSTALLATION

Carefully remove all contents from the carton. Shut off the power at the circuit breaker and completely remove the old fixture from the ceiling, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. Remove cap nuts (G) from mounting screws (J). Put the drywall anchor (A) inside the hole in the ceiling. Place the mounting plate (B) over the junction box so that mounting screws (J) extend out away from the ceiling. Pull the house wires through the center of mounting plate (B). Secure mounting plate (B) to the junction box by tightening the screws (D) then insert the drywall screw (C) through the mounting plate (B) into the drywall anchor (A).

ASSEMBLING THE FIXTURE

There are 4 12-inch rods (P), and 1 6-inch rod (Q) included for each side of the fixture. Determine the correct number of rods needed for proper hanging height. To lengthen the fixture, add additional rods. To shorten the fixture, trim the wires to desired length. Leave at least 8 to 10 inches of wire in addition to the desired length and slide any excess rods off the fixture’s wiring to discard. Keep in mind that you must use at least one rod to hang the fixture. Thread the wires through the rods and pull the wires until taut before connecting the rods together. All threads should be engaged but do not overtighten (some manual straightening of the downrods may be required). Screw the lower end of rod onto threaded post (R) of the fixture. Place reinforcing plate (E) inside canopy (F) and the canopy (F) over the threaded post (O) of the top rod. Put one side of threaded post (O) though the wirerope noose (N) and washer (M). Secure the reinforcing plate and canopy (F) with the wing nut (K) on threaded post (O). Hide wirerope inside the canopy (F). Secure the screw collar loop (H) into mounting plate (B).

Hunter-13055-Donelson-5-Light-Linear-Chandelier-fig-
\(1\)

CONNECTING THE WIRES

Have a helper support the fixture’s weight while completing the wiring. Attach the fixture’s wires to the power supply wires from the junction box. Connect black to black (live); white to white (neutral); grounding to grounding (green or copper). Twist the ends of the wire pairs together. Then twist on a wire connector. Make sure all twists are in the same direction. Loop fixture’s ground wire around grounding screw (L) and tighten. If there is no ground wire (green or copper) from the junction box, contact a qualified electrician.

FINISHING THE INSTALLATION

Raise canopy (F) to mounting plate (B) and position mounting screws (J) so that they protrude through the openings of canopy (F). Secure canopy (F) in place with cap nuts (G). Install light bulbs (not included) in accordance with the fixture’s specifications. Do not exceed the recommended wattage. Turn on the power and test the fixture. Your installation is now complete.

CLEANING TIPS

Treat the fixture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth. Never spray cleaner directly onto the fixture.

NOTICE

  • Drill 9/64″ pilot holes in support structure to aid in securing light fixture.
  • In order to use a 12in. rod by itself you must first remove the threaded post from the 6in. rod and install it on one of the ends of the 12in. rod.

Hunter Pro Tip:
Twist or tape wire ends together to make it easier to pass them through the downrods. Threaded post may also be removed for easier wire access.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals