CHADHA POWER STAR Series Inverter or UPS User Manual

June 11, 2024
CHADHA POWER

CHADHA POWER STAR Series Inverter or UPS

CHADHA-POWER-STAR-Series-Inverter-or-UPS-product

Congratulations on choosing the CHADHA POWER STAR Inverter/UPS. This product provides complete comfort during the absence of utility power and provides your appliances with the exact replication of the main supply. The CHADHA POWER STAR Series of Pure Sine Wave Inverters transforms Direct Current (DC) to Alternating Current (AC). The battery acts as a reservoir ensuring continuous supply when utility power is not available.

Salient Features

  • Continuous power supply during utility power absence
  • Pure Sine Wave Inverter for exact replication of mains supply
  • Two battery wires with Resettable Thermal Circuit Breaker 7/10Amp (7Amp – 650/850/1050 VA & 10Amp -1450 VA), output socket, and a power cord to connect to the mains supply

Product Usage Instructions

  1. Read the installation and operating instructions in the manual carefully before installing and using your Chadha Power STAR Inverter/UPS. Pay special attention to the CAUTION and WARNING statements in this manual.
  2. Connect the red-colored battery wire to the positive terminal of the battery and black colored wire to the negative terminal of the battery.
  3. The output side of the AC wiring of the CHADHA POWER STAR Inverter/UPS should never be connected to the utility. Ensure that the AC output of the CHADHA POWER STAR Inverter/UPS should not connected to the AC input.
  4. Before installing, connecting any wiring, or using the CHADHA POWER STAR Inverter/UPS, read all instructions carefully.
  5. Do not leave batteries in a discharged state for more than a day or two. They will undergo a chemical process called sulfation which can permanently damage the battery. Also, batteries will self-discharge over a period of time, so they should periodically be recharged even if they are not being used.
  6. Someone should be in your audible range to come to your aid when you work near batteries. Have plenty of fresh water nearby in case battery acid contacts skin, clothing, or eyes.
  7. Before touching battery terminals make sure that the system is OFF and AC mains to the CHADHA POWER Inverter is also OFF. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with an electrical circuit. These items can cause a short circuit current high enough to weld a ring and may cause severe burns.
  8. CAUTION: The Chadha Power Inverters Pure Sine Wave should be connected to grounded, permanent wire systems. The CHADHA POWER STAR Inverter/UPS is for use with a nominal supply voltage.

Dear Valued Customer,
We congratulate you on your excellent choice of our CHADHA POWER STAR INVERTER/UPS. Chadha Power STAR Series of Pure Sine Wave Inverters will provide you complete comfort during the absence of utility power and provide your appliances the exact replication of mains supply.

The salient features of the CHADHA POWER STAR SERIES of Inverters are:

  • Pure Sine Wave Output Wave Shape
  • Automatic Battery Charge Management
  • Dual Mode of Charging i.e. Normal & High Charging Rates
  • LED Indications for better user interface
  • Automatic Overload, Battery Low, Over Temperature & Short Circuit protection sense
  • Wide Mains Voltage Charging Range i.e. 90V – 300V
  • Mains Low Voltage Charging Facility
  • Reverse Phase Protection
  • Great Power Saving
  • Easy to Service
  • No Humming Noise

This manual provides you with a thorough understanding of your Chadha Power STAR INVERTER and its optimum use. Please read the installation and operating instructions in the manual carefully before installing and using your Chadha Power STAR Inverter. Pay special attention to the CAUTION and WARNING statements in this manual.

About the CHADHA POWER STAR Series of Inverters
Chadha Power Star Series of Pure Sine Wave Inverters transforms Direct Current (DC) to Alternating Current (AC). The battery acts as a reservoir ensuring continuous supply when utility power is not available.

Controls

Front Panel

CHADHA-POWER-STAR-Series-Inverter-or-UPS-fig- \(2\)

Rear Panel

Chadha Power Star Inverters have two battery wires coming out from the rear side, a Resettable Thermal Circuit Breaker 7/10Amp (7Amp – 650/850/1050 VA & 10Amp -1450 VA), an output socket, and a power cord to connect with the mains supply. Red colored battery wire is to be connected to the positive terminal of the battery and black-colored wire is to be connected to the negative terminal of the battery.

Caution:
Do not reverse the battery connections, it will blow the DC fuse connected in series with the battery connection inside the Power Card.

CHADHA-POWER-STAR-Series-Inverter-or-UPS-fig- \(1\)

Some Safety Measures

Precautions

Important Precautions
The output side of the AC wiring of Chadha Power Inverterz should never be connected to utility Installation should ensure that the AC output of Chadha Power Inverterz should not be connected to the AC input.

Note:
While connecting the battery cables to the Chadha Power Inverterz, there may be sparks on the battery terminals, usually accompanied by a “snap”. This is normal, don’t let it scare you.

Never disconnect battery cables while the Chadha Power Inverter is delivering power or the battery charger is operating. Always turn the switch off first.

General Precautions

  • Before installing, connecting any wiring, or using the Chadha Power Inverter, read all instructions of this instruction manual.
  • Do not expose the system to rain, snow, or liquids of any type. Do not disassemble the system; call Chadha Power’s authorized service center when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire.
  • To reduce the risk of electric shock, disconnect all the wiring from the system before attempting any maintenance cleaning. Turning off the system will not reduce this risk
  • WARNING: WORKING IN THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS
  • Be extra cautious when working with metal tools on, or around batteries. The potential exists to drop a tool and short-circuit the batteries or other electrical parts resulting in sparks that could cause an explosion
  • Do not leave batteries in a discharged state for more than a day or two. They will undergo a chemical process called sulfation which can permanently damage the battery. Also, batteries will self-discharge over a period of time, so they should periodically be recharged even if they are not being used.
  • GROUNDING INSTRUCTIONS: The Chadha Power Inverter Sine Wave should be connected to a grounded, permanent wiring system.

Personal Precautions

  • Someone should be in your audible range to come to your aid when you work near batteries.
  • Have plenty of fresh water nearby in case battery acid contacts skin, clothing, or eyes.
  • Wear complete eye protection and clothing protection. Avoid touching your eyes while working near batteries. Wash hands when done.
  • If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters the eyes, immediately flood the eyes with running cool water for at least 15 minutes and get medical attention immediately.
  • Never attempt to charge a frozen battery.
  • Before touching battery terminals make sure that the system is OFF and AC mains to the CHADHA POWER Inverter is also OFF.
  • NEVER smoke or allow spark or flame in the vicinity of the batteries.
  • Remove personal metal items such as rings, bracelets, necklaces, and watches when working with an electrical circuit. These items can cause a short circuit current high enough to weld a ring and may cause severe burns
  • If it is necessary to remove any battery, always remove the grounded terminal from the battery first. Make sure all the accessories are off, so as not to cause arcing. Be sure that the area around the battery is well-ventilated.
  • Clean battery terminals. Be careful not to allow corrosion to come in contact with your eyes.
  • Study all battery manufacturers’ specific precautions and recommended rate of charge.
  • Add only distilled water in each cell until battery acid reaches the level specified by the battery manufacturer. This helps purge excess gas from cells. Do not overfill. For a battery without caps, carefully follow the manufacturer’s charging instructions.
  • CAUTION: The Chadha Power Inverter Pure Sine Wave should be connected to a grounded, permanent wire system.

SPECIAL NOTICES:

  1. The Chadha Power Star Inverter is for use with a nominal supply voltage of 12V/ 24V DC.
  2. No AC or DC disconnects are provided as an integral part of this system.
  3. No over-current protection for the battery supply is provided as an integral part of this system. Both AC & DC disconnects must be provided as part of the system installation.
  4. No over-current protection for the AC output wiring is provided as an integral part of the system. Over-current protection of the AC output wiring shall be provided as part of the system installation.

Charging and Load Chart

CHARGING MODE

CHADHA-POWER-STAR-Series-Inverter-or-UPS-fig- \(2\)

LOAD CHART CHADHA POWER INVERTERZ

CHADHA-POWER-STAR-Series-Inverter-or-UPS-fig- \(3\)

Depending on the actual VA rating/technical specifications of the appliance. Specifications are subject to change without prior notice due to constant R&D effort.

APPLICATION CHART CHADHA POWER INVERTERS

Back-up Power of all electrical loads:

  • Computer & Printers
  • Fan, Tubelights, CFL, LED Lights
  • T.V. Sets, DVD & Music System

Installation

Where to install

The system should be installed in a location that meets the following requirements:

  • Dry – Do not allow water to drip or splash on the Chadha Power Inverter
  • Cool- The ambient air temperature around the system should be between 0°C to 45°C (32°F to 113°F. A cooler environment is better for the system.
  • Ventilation: Allow at least two inches (5cm) of clearance around the system for airflow.
  • Safe: Do not install the Chadha Power Inverter in the same compartment as batteries or in any compartment which is storing flammable liquids such as gasoline.
  • Close to the battery – Install the system as close to the battery as possible in order to minimize the length of cable required to connect the system to the battery. It is better and cheaper to run longer AC wires than longer DC cables.

CAUTIONS!
To prevent fire, do not cover or obstruct ventilation openings. Do not install the system in a zero-clearance compartment. Overheating may result.

WARNING!
This equipment contains components that tend to produce arcs or sparks. To prevent fire or explosion do not install in compartments containing batteries or flammable materials or in locations that require ignition-protected equipment.

How To Install

DC Cabling:

  1. Ensure that the ON/OFF switch on the front panel of the Inverter is in the OFF position before you begin the installation
  2. Connect the negative terminal of the battery to the thick black wire of the system
  3. Connect the positive terminal of the battery to the thick red wire of system

AC Cabling:
Plug in the power cord to the main socket on the wall. The cabling should have proper earthing. Input supply should remain ON once the system is installed. Take the output from the output socket.

CHADHA-POWER-STAR-Series-Inverter-or-UPS-fig- \(4\)

Start Operation

Once the AC and DC wiring has been installed and connected, take a moment to go re-examine all the connections and make sure they are secured and in the proper terminals

  1. Check to see that the Chadha Power Inverter is turned off and then apply battery (DC) power to it. Ensure that all wiring has been installed properly. Next turn On the battery bank DC disconnects or connect the proper fuse in line to the battery to complete the battery circuit.
  2. Put the ON/OFF switch in the ON position. This system should run a load without AC input (battery only). Place a load on the system and make sure it works.
  3. To charge your batteries connect AC power to the system by plugging in the AC power and turning on the mains line. This shows that the charger is working properly. Any AC load powered by the system should also work at this point since a portion of the AC power is passed through this Chadha Power Inverter to power the loads.
  4. Disconnect the AC Power, the system should transfer to battery mode immediately. This will be indicated by clicking sound as the internal transfer relay changes position.
  5. The system will begin to take power from the batteries and use it to power the load. And the load continues to operate uninterrupted.

The above steps will complete the functional test of the Chadha Power Inverter. If all areas pass, the system is ready for use. If something fails, figure out the reason before proceeding or contact the service center.

DO NOT MIX WITH OTHER WASTES FOR DISPOSAL
To prevent possible harm to the environment or human health this product should not be disposed of with other waste. Household users should contact either their retail seller or local government office for safe recycling. Business users should contact their suppliers and check the terms and conditions of the purchase contract for proper disposal.

Maintenance

Very little maintenance is required to keep your Chadha Power Star Inverter operating properly. You should clean the exterior of the unit periodically with a damp cloth to prevent the accumulation of dust and dirt.

Troubleshooting Guide

CHADHA-POWER-STAR-Series-Inverter-or-UPS-fig- \(5\)

Specifications

Technical Specifications

CHADHA-POWER-STAR-Series-Inverter-or-UPS-fig- \(6\)

INDIA

CHADHA POWER LLP
F-Block, Ground Floor The Mira Corporate Suites 1 & 2, Old Ishwar Nagar, Mathura Road New Delhi – 110065, India.
Tel: + 91 11 26910057
Website: www.chadhapower.com.
Email: [email protected].

SOUTH AFRICA

CHADHA POWER (SA) (PTY) LTD Unit 30, Bridgeway Business Park 496 Pinnacle Street, Tunney Germiston, 1401 South Africa.
Tel: +27 11 708 0001
Website: www.chadhapower.co.za.
Email: [email protected].