DELTA SV-96RD-24V Indoor Sirens User Manual
- June 11, 2024
- Delta
Table of Contents
DELTA SV-96RD-24V Indoor Sirens
Product Information
The SV-96RD/24V is a small indoor siren designed for use in intruder alarm systems. The siren has both optical and acoustical signaling capabilities, with LEDs serving as the optical signaling source and a piezo transducer generating the acoustical signaling. The device has been designed with safety in mind and must be protected from contact with caustic, staining, and viscous fluids.
- Sound pressure level: [not provided]
- Power supply: [not provided]
- Maximal current consumption: [not provided]
- Internal backup battery: [not provided]
- Color: [not provided]
- Operation temp: [not provided]
- Weight: [not provided]
- Dimensions: [not provided]
- Guarantee: [not provided]
Product Usage Instructions
- Ensure that the siren is properly mounted in a secure location indoors.
- Connect the siren to the power supply and ensure that the maximal current consumption is not exceeded.
- In the event of an intrusion, the siren will activate both optical and acoustical signaling to alert those in the vicinity.
- If the siren is exposed to any caustic, staining, or viscous fluids, immediately disconnect it from the power supply and clean the affected area with a dry cloth.
- Refer to the user manual for further information on product specifications and safety guidelines.
Warning!
- Please read the user manual included in this work as it contains important information related with safety of installation and use of the device.
- Only persons who read the user manual may use the device.
- The user manual must be kept because it may be required in the future. The device is to be used exclusively for purposes specified in this user manual.
- The device must be unpacked prior to starting-up. After removing the packaging make sure the device is in working order.
- If the product has defects, it should not be used until it is repaired.
- The product is intended for use at home and commercial use and may not be used for other than intended use.
- The manufacturer is not liable for damages resulting from not adhering to the rules contained in the user manual, therefore, we recommend to follow the aforementioned safety rules for operation and maintenance of the device. In this way you will ensure yourself safety and avoid causing damage to the device.
- The manufacturer and the supplier are not liable for losses or damages arising out of the product, including financial or intangible losses, loss of profits, income, data, pleasure from use of the product or other products related with it – indirect, incidental or consequential loss or damage. The above provisions apply whether the loss or damage concerns:
- Deterioration of quality or the lack of operation of the products or products related with it due to damage as well as the lack of access to the product when it is undergoing repair, which results in stoppage the loss of user’s time or a break in business activity;
- Improper results of operation of the product or products related with it;
- It applies to losses and damages according to any legal category, including negligence and other losses, termination of a contract, expressed or implied guarantee and strict liability (even if the manufacturer or the supplier was notified about the possibility of occurrence of such damages).
Safety measures
- Particular attention at designing was directed to the quality standards of the device where ensuring safety of operation is the most important factor.
- The device must be secured against contact with caustic, staining and viscous fluids.
- The device was designed in such a way that it restarts operation when the power supply is restored after a break.
- Attention! We recommend using protections to further protect the device from possible overvoltages in installations. Surge protectors are effective protection against the accidental pass to the device voltages higher than the rated. Damages caused by passing the voltages higher than specified in manual are not under warranty.
- Turn off the device before transporting it.
- Prior to connecting the device to a power source check whether the supplied voltage is consistent with the rated voltage specified in the user manual.
Proper product disposal:
- A marking of a crossed-out waste bin indicates that the product may not be disposed of together with other household waste in the entire EU. To avoid possible damage to the natural environment of health due to uncontrolled waste disposal, therefore, it should be handed over for recycling, propagating in this way sustainable use of natural resources.
- To return a worn-out product, use a collection and disposal system of this type of equipment or contact a seller from whom it was purchased. He will then be recycled in an environmentally-friendly way.
The SV-96RD/24V small indoor siren with optical and acoustical signaling is designed for operation in the intruder alarm systems. Optical signaling source are LEDs, and acoustical signaling is generated by the piezo transducer.
- Code : SV-96RD/24V
- INDOOR SIREN SV-96RD/24V
Sound pressure level: | 109 dB/m |
---|
Main features:
| • Piezoelectric transducer
• LED diodes
• Plastic (ABS)
• Power cord : 40 cm
Power supply:| 24 V DC
Maximal current consumption:| 150 mA
Internal backup battery:|
Color:| Red / LED indication – Red
Operation temp:| -35 °C … 60 °C
Weight:| 0.1 kg
Dimensions:| 122 x 74 x 44 mm
Guarantee:| 2 years
Internal view
Mounting side view
PACKAGE
- Dimensions ( L x W x H): 0x0x0 mm
- Gross Weight : 0 kg
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl POL; 60-713 Poznań;
Graniczna 10
e-mail: delta-opti@delta.poznan.pl ;
tel: +(48) 61 864 69 60
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>