Product Information
The product is a steam generator kit that includes CU1-D1 and CU2-D1 kits. It is designed to serve one room using two steam solenoid valves and two steam heads. The kit requires digital 1 control installation and comes with operating parameters. The temperature sensor installation requires .06, 4.50, 2.38 1.11 and 3.00 1.36 4.50 mr. steam.
PRODUCT CU1-D1 KIT CONTENT
- Steam solenoid valve
- Steamhead
product CU2-D1 KIT CONTENT
- Steam solenoid valve
- Steamhead
product Steamhead Installation
- If the steam room is constructed of tile, marble or similar nonporous heat-resistant materials for the enclosure, locate steam head 12 inches above the steam room floor and install Mr.Steam PN CU-103985 acrylic shield on each steam head.
- For steam rooms using acrylic, fiberglass, or other non-heat-resistant materials used for steam room enclosure, install each steamhead 20-30 inches above the floor.
- Locate each steamed away from the bather seating area and away from traffic patterns as required to prevent incidental contact with steamhead or direct steam emissions.
- NOTE: To preserve the steamed finish, do not use a wrench or other tools to tighten it. Use of proper thread sealant and hand tightening is usually sufficient.
- Apply a bead of silicone around the steam head where it meets the wall as required to prevent moisture damage.
Acrylic Shield Installation
- Apply a small bead of silicone in the grooves on the top and bottom of the steam head.
- Place an Acrylic Shield (PN 103985) over the steamed until the tabs engage the grooves in the steam head.
product Steam Solenoid Valve Installation
The steam solenoid valve is powered by the CU Steam Generators 120 VAC control circuit. Refer to PUR 100376 for installation instructions. It is recommended to visit mrsteam.com before installation to download the Installation, Operation, and Maintenance Manual or refer to the manual provided with the unit for safe and trouble-free installation.
Technical Specifications
CU1-D1 KIT CONTENT
- Digital 1 Control (factory installed on generator)
- Digital 1 Sensor
- One ¾” Steam Solenoid Valve and ¾” Steamhead
- Acrylic Shield
- Sensor Cover
CU2-D1 KIT CONTENT
For CU 2000 – 4500 serving one room using two steam solenoid valves and two
steamheads.
- Digital 1 Control (factory installed on generator)
- Two ¾” Steam Solenoid Valve and ¾” Steamhead
- Digital 1 Sensor
- Two Acrylic Shields, one for each steamhead
- Sensor Cover
DIGITAL 1 CONTROL INSTALLATION
- Digital 1 Control uses 120V, 1PH control voltage supply.
- If Digital 1 Control is not factory installed on generator, refer to PUR 100376 for installation instructions.
OPERATING PARAMETERS
- Operating Temperature Range 80-120°F (26.5 – 49°C)
- Backup Temperature shut off fixed at 130°F (54.5°C)
BACKUP TEMPERATURE SHUT-OFF
- In the event room conditions or environment cause the temperature to reach 130 °F (54.5 °C) the Digital 1 Control will shut off power to the steam bath generator.
- The Digital 1 control will reset when the temperature in the room reaches normal operating range.
TEMPERATURE SENSOR INSTALLATION
- Locate sensor on a wall inside the steam room five (5) feet above the floor
- Do NOT locate the Digital 1 sensors near or above the steamhead(s) as this may cause direct steam emission to interfere with steam room temperature regulation.
- Do NOT route sensor cable with power wiring, next to electric motors or any other location subject to electrical noise.
The Digital 1 Control maintains selected room temperature and features a high limit shut-off. Provides Steam-On-Demand® for consistent room temperature comfort and control.
STEAMHEAD INSTALLATION
-
For steam rooms constructed of tile, marble or similar nonporous heat-resistant materials for the enclosure, locate steam head 12 inches above steam room floor and install Mr.Steam PN CU-103985 acrylic shield on each steamhead.
IMPORTANT: For Steam rooms using acrylic, fiberglass or other non-heat resistant materials used for steam room enclosure, install each steamhead 20-30 inches above the floor. -
Locate each steamhead away from bather seating area and away from traffic patterns as required to prevent incidental contact with steamhead or direct steam emissions.
-
NOTE: To preserve the steamhead finish, do not use wrench or other tools to tighten. Use of proper thread sealant and hand tightening is usually sufficient.
-
Apply a bead of silicone around the steamhead where it meets the wall as required to prevent moisture damage.
ACRYLIC SHIELD
Apply a small bead of silicone in the grooves on the top and bottom of the
steamhead. Place an Acrylic Shield (PN 103985) over the steamhead until the
tabs engage the grooves in the steam head.
STEAM SOLENOID VALVE INSTALLATION
The steam solenoid valve is powered by the CU Steam Generators 120 VAC control
circuit.
- he steam solenoid valve:
- Should be plumbed as close as practical to the steam room
- Must be installed outside the steam room
- Must remain accessible for service
- Shall be plumbed horizontally
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE-FREE INSTALLATION
Visit mrsteam.com before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
MODEL | PROJECT INFORMATION |
---|
CU1-D1
CU2-D1
| Location:| Contractor:
Architect:| Submitted By:
Engineer:| Date:
Notes:
hello@mrsteam.com • www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM
References
- Home | Steam Shower Generators Controls Accessories | MrSteam
- Home | Steam Shower Generators Controls Accessories | MrSteam
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>