CONDTROL NEO G200 Laser Distance Meter Vector
Product Information
Product Name
CONDTROL NEO G200 Cross Line Laser
Safety Instructions
- The user manual is an essential part of this product and should be read carefully before use.
- Do not misuse the product.
- Do not remove warning signs and protect them from abrasion, as they contain information about safe operation.
- Avoid heating batteries to prevent explosion and electrolyte leakage.
- In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water for 10 minutes and consult a doctor.
Product Description
The CONDTROL NEO G200 Cross Line Laser is designed for building and checking vertical and horizontal planes and lines. It has two operating modes: Automatic leveling for building horizontal and vertical planes and lines, and Locked compensator for building inclined planes and lines.
Technical Specifications
- Working range: Not specified
- Self-leveling accuracy: Not specified
- Self-leveling range: Not specified
- Operating temperature: Not specified
- Storage temperature: Not specified
- Tripod mounting thread: 5/8″, 1/4″
- Laser type: Class II 520 nm < 1 mW
- Power supply: 3 x 1.5V LR6 alkaline (AA) batteries
- Dimensions: 120 x 75 x 105mm
- Weight: 0.5 kg
Product Usage Instructions
- Read the user manual carefully before using the product for the first time.
- Move the compensator lock to choose the necessary operating mode:
- Automatic leveling for building horizontal and vertical planes and lines: Move the lever lock to the unlocked position. The compensator will be unlocked. If the product is out of the range of automatic compensation, it will emit a sound signal.
- Locked compensator for building inclined planes and lines: Move the lever lock to the locked position.
- Short press the button to turn on necessary laser planes.
- Short press the button to turn on/off pulse mode that allows working with laser receiver. In this mode, the pulse mode indicator will turn green.
- To switch off the product, move the lever lock to the locked position.
- Do not heat batteries to avoid explosion and electrolyte leakage.
- If liquid comes into contact with skin, wash immediately with soap and water. If it comes into contact with eyes, flush with clean water for 10 minutes and consult a doctor.
- Do not misuse the product and do not remove warning signs as they contain information about safe operation.
SAFETY INSTRUCTIONS
Attention! This user manual is an essential part of this product.
The user manual should be read carefully before you use the product for the
first time. If the product is given to someone for temporary use, be sure to
enclose user manual to it.
- Do not misuse the product
- Do not remove warning signs and protect them from abrasion, because they contain information about safe operation of the product.
- Do not look into the laser beam or its reflection, with unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.
- To protect your eyes close them or look aside.
- Always install the product in such a way, so that laser line is below or above eye level.
- Do not let unauthorized people enter the zone of product operation.
- Store the product beyond reach of children and unauthorized people.
- It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified personnel and use original spare parts only.
- Do not use the product in explosive environment, close to flammable materials.
- Laser intensive glasses are used for better recognition of the laser beam, do not use them for other purposes. Laser glasses do not protect from laser radiation as well as ultraviolet radiation and reduce color perception.
- Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water during 10 minutes and consult the doctor.
PRODUCT DESCRIPTION
Cross line laser NEO G200 CONDTROL is intended to build and check vertical and
horizontal planes and lines.
The product has 2 operating modes:
- locked compensator, to build inclined planes and lines;
- automatic leveling to project horizontal and vertical planes and lines. Leveling function allows to automatically compensate irregularities within self-leveling range of ±4,5°.
- Laser lines exit window
- Control panel
- Battery cover
- 5/8’’ mounting thread
- Compensator lock
- Mounting screw hole
- Mounting clip
- Belt mount hole
- Power jack
Control panel
- Turn on/off laser lines in unlocked mode
- Turn on/off:
- Pulse mode
- Laser lines in locked mode
- Battery charge level indication
- Locked pendulum indication
- Pulse mode indication
TECHNICAL SPECIFICATIONS
Working range | 50 m* |
---|---|
Self-leveling accuracy | ±0,3 mm/m |
Self-leveling range | ± 4,5° |
Operating temperature | 0°C … +50°C |
Storage temperature | -20°C … +70°C |
Tripod mounting thread
| ****
5/8’’, 1/4’’
Laser type| Class II 520 nm < 1 mW
Power supply| 3 х 1.5V LR6 alkaline (AA)
Dimensions
| ****
120х75х105mm
Weight| 0,5 kg
The operating range may differ from the declared depending on the lighting conditions.
SET
- Laser level – 1 pc.
- Magnetic holder – 1 pc.
- Adapter 5/8’’ – 1/4’’ – 1 pc.
- Cable tie – 1 pc.
- Power supply cable – 1 pc.
- Pouch – 1 pc.
- Batteries (AA) – 3 pcs.
- User manual – 1 pc.
OPERATION
Before start operation remove the battery cover, insert the
batteries,observing correct polarity. Put battery cover back.
Use alkaline AA batteries only, all batteries should be of the same type and
brand with the same charge level. If battery charge level indicator turns red
while operation replace batteries or remove batteries from the laser level and
connect it to external power source using the power supply cable included in
the package. It is prohibited to connect laser level to external power supply
if alkaline batteries (AA) are installed.
Place an instrument on a firm and stable surface or a tripod.
Move compensator lock to choose necessary operating mode:
Automatic leveling, to build horizontal and vertical planes and lines:
Move lever lock to unlocked position . Compensator is unlocked.
If the product is out of the range of automatic compensation it will emit
sound signal.
Short press button to turn on necessary laser planes.
Short press button to turn on/off pulse mode that allows working with laser
receiver. In this mode pulse mode indicator will turn green.
To switch off the product move lever lock to locked position .
Locked compensator, to build inclined planes and lines:
Move lever lock to locked position . Compensator is locked. Short press button
to turn on the product. Horizontal plane will switch on. Locked pendulum
indicator turns red.
Short press button to turn on necessary laser planes.
ACCURACY CHECK
Check of horizontal line
Check of horizontal line is carried out by using 2 walls located opposite each
other at a distance of 5m.
-
Put the instrument as close as possible to the wall so that laser emitters are located opposite the wall.
-
Move lever lock to unlocked position and switch on horizontal plane.
Mark location of horizontal line on the wall as A1. -
Turn the instument by 180° and mark location of horizontal line on another wall as B1
-
Turn the instrument to the right. Measure vertical deviation of horizontal line from point B1. If deviation exceeds 1,5 mm – please contact service center.
-
Repeat actions in paragraph 4 by turning the instrument to the left.
-
Install the instrument closer to the opposite wall. Mark location of horizontal line on the wall as B2.
-
Turn the instrument by 180° and mark location of horizontal line on the opposite wall as A2.
-
Measure vertical distance between marks A1, A2 and B1, B2. If distance between measured values exceeds 3 mm – please contact service center.
Check of vertical line
Use a plumb bob as a reference of a vertical. Place the instrument at distance
of 1,5 m from the plumb bob.
- Move lever lock to unlocked position , then switch on vertical plane and align vertical laser line with the low point of plumb bob.
- If deviation between the laser line and the plumb line exceeds ±0,3 mm per 1 m of the plumb bob length (for a 2,5 m plumb bob deviation shouldn’t exceed 0,75 mm) please contact service center.
CARE AND MAINTENANCE
Attention! The product is an accurate optical mechanic device and
requires careful handling. Check the accuracy before using.
To increase the operating time and avoid the risk of unintentional blindness
switch the laser on only when you are ready to make measurements.
If operated near objects or air streams with different from the environment
temperature the laser line may tremble due to heterogeneity of the atmosphere.
The longer is the distance, the more trembling can be observed
The width of the laser line increases with the increasing of the operating distance. The layout should be made along the axis of the laser line. For maximum accuracy, use the middle portion of the laser line.
It should be noted that the shape of the laser line on the object’s surface (e.g., walls, ceilings, etc.) depends on the curvature and tilt of the surface relative to the laser plane.
Maintenance of the following recommendations will extend the life of the device:
- Transport and carry the product only with locked compensator.
- Keep the product clean and protected from any bumps, dust and dampness; do not allow getting moisture, dust or other dirt inside of the product.
- In case if any moisture goes into the product, remove the batteries and take it to the service center.
- Do not keep or use the device for a long time at high humidity conditions.
- Keep the instrument clean and wipe it with a clean and soft cloth.
Mishandling of the following rules can cause electrolite leakage from the batteries or other damages:
- Remove the batteries from the product if you do not use it for a long time.
- Do not use different battery types with different charge levels.
- Do not leave discharged batteries in the product.
UTILIZATION
Expired tools, accessories and package should be passed for waste recycle.
Please send the product to the following address for proper recycle:
CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany
Do not throw the product in municipal waste!
According to European directive 2002/96/ЕC expired measuring tools and their
components must be collected separately and submitted to environmentally
friendly recycle of wastes.
WARRANTY
All CONDTROL GmbH products go through post-production control and are governed by the following warranty terms. The buyer’s right to claim about defects and general provisions of the current legislation do not expire.
- CONDTROL GmbH agrees to eliminate all defects in the product, discovered while warranty period, that represent the defect in material or workmanship in full volume and at its own expense.
- The warranty period is 24 months and starts from the date of purchase by end consumer (see the original supporting document).
- The Warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the product caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, the use of non-original accessories and spare parts. Modifications in design of the product relieve the seller from responsibility for warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder normal operation of the product.
- CONDTROL GmbH reserves the right to decide on replacement or repair of the device.
- Other claims not mentioned above, are not covered by the warranty.
- After holding warranty works by CONDTROL GmbH warranty period is not renewed or extended.
- CONDTROL GmbH is not liable for loss of profit or inconvenience associated with a defect of the device, rental cost of alternative equipment for the period of repair.
This warranty applies to German law except provision of the United Nations
Convention on contracts for the international sale of goods (CISG).
In warranty case please return the product to retail seller or send it with
description of defect to the following address:
CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany
LASER DISTANCE METERS
LASER LEVELS
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>