LANCOM 1793VA-4G+ Wireless Router User Guide

June 9, 2024
LANCOM

LANCOM 1793VA-4G+ Wireless Router

LANCOM-1793VA-4G-Wireless-Router-PRO

OVERVIEW

LANCOM-1793VA-4G-Wireless-Router-1

  1. LTE / 4G antennas
    Connect the two supplied cellular antennas to the connectors Ant 1 and Ant 2.

  2. VDSL / ADSL interface
    Use the supplied DSL cable for the IP-based line to connect the VDSL interface and the provider’s telephone socket. For more information, please contact your Internet service provider.

  3. Ethernet interfaces
    Use an Ethernet cable to connect one of the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.

  4. SIM card slot (device bottom)
    Release the SIM-card holder and lever it upwards. Slide the SIM card into the guide slot of the SIM-card holder. Press the holder down until it clicks into place.

  5. Analog interfaces
    Connect analog terminal devices to the analog interfaces either directly via RJ11, or with the help of the enclosed TAE adapters. Further adapters are optionally available.

  6. Configuration interface
    Use a serial configuration cable to connect the serial interface (COM) to the serial interface of the device you want to use for configuring / monitoring (separately available).

  7. ISDN interfaces
    ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS.
    ISDN 2: Internal (NT) ISDN bus. A 100-Ohm resistor for line termination is switchable in LCOS.

  8. USB interface
    You can use the USB interface to connect a USB printer or a USB memory stick.

  9. Power
    After connecting the cable to the device, turn the bayonet connector 90° clockwise until it clicks into place. Use only the supplied power adapter.

Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a nearby power socket that is freely accessible at all times.

Please observe the following when setting up the device

  • The power plug of the device must be freely accessible.
  • For devices to be operated on the desktop, please attach the adhesive rubber footpads
  • Do not rest any objects on top of the device
  • Keep all ventilation slots on the side of the device clear of obstruction
  • In case of wall mounting, use the drilling template as supplied
  • Rack installation with the optional LANCOM Rack Mount (separately available)

Mounting & connecting

LANCOM-1793VA-4G-Wireless-Router-11

Power

  • **Green, permanently*** Device operational, resp. device paired / claimed and LANCOM Management Cloud (LMC) accessible
  • Red/green blinking Configuration password not set. Without a configuration password, the configuration data in the device is unprotected.
  • Red blinking Charge or time limit reached
  • 1x green inverse blinking * Connection to the LMC active, pairing OK, device not claimed
  • **2x green inverse blinking*** Pairing error, resp. LMC activation code not available
  • **3x green inverse blinking*** LMC not accessible, resp. communication error

Online

  • Green, blinking WAN connection is established (e.g. PPP negotiation)
  • Green, permanently WAN connection active
  • Red, permanently WAN connection error

DSL

  • Green, permanently DSL connection active
  • Green, flickering DSL data transfer
  • Red, flickering DSL transfer error
  • Red / orange, blinking DSL hardware error
  • Orange, blinking DSL training
  • Orange, permanently DSL sync
  • Green, blinking DSL connecting

Analog

  • Green, permanently Interface activated
  • Orange, blinking Incoming call
  • Green, blinking Connection active

ISDN

  • Green, permanently D-channel active
  • Green, flickering ISDN data transfer
  • Red, flickering ISDN transfer error
  • Red / orange, blinking ISDN hardware error

ETH

  • Green, permanently Connection to network device operational, no data traffic
  • Green, flickering Data transmission

4G

  • Green, permanently Connection to cellular network active
  • Green, flickering Cellular data transfer
  • Orange, permanently Logon to cellular network successful
  • Orange, blinking Logging on to cellular network
  • Red, permanently Hardware error/module unavailable
  • Red/green, blinking SIM card error (PIN)
  • Red/orange, blinking Uploading module firmware

VoIP

  • Off No SIP accounts defined or VCM is off
  • Green, permanently All defined and active SIP accounts (outgoing) were successfully registered
  • Red, permanently Not all defined and active SIP accounts were registered (possibly still in process)
  • Red or green, inverse flashing Number of currently used lines (connecting or connected)

VPN

  • Green, permanently VPN connection active
  • Green, flashing VPN connecting

Reset

  • Reset button Operated e.g. with a paper clip short press: Restart the device long press: Reset the device

Hardware

  • Power supply 12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection
  • Power consumption Max. ca. 18 W
  • Environment Temperature range 0–40 °C; humidity 0–95 %; non-condensing
  • Housing Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; measures 210 x 45 x 140 mm (W x H x D)
  • Number of fans 1 quiet fan

Interfaces

  • WAN: VDSL2
    • VDSL2 as per ITU G.993.2; profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 35b
    • VDSL Supervectoring as per ITU G.993.2 (Annex Q)
    • VDSL2 vectoring as per ITU G.993.5 (G.Vector)
    • Compatible to VDSL2 from Deutsche Telekom
    • Compatible to U-R2 from Deutsche Telekom (1TR112)
    • ADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO, ITU G.992.3, and ITU G.992.1
    • ADSL2+ over POTS as per ITU G.992.5 Annex A/M with DPBO, ITU G.992.3, and ITU.G.992.1
    • Supports just one virtual connection at a time in ATM (VPI-VCI pair)
  • ETH 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode. Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically disabled in the LCOS configuration.
  • 4G: Ant 1 / 2 Two SMA connectors for the supplied dipole rod antennas (LTE, UMTS), compatible LANCOM AirLancer antennas for 4G or 3G, or from other manufacturers. Please respect the restrictions which apply in your country when setting up an antenna system (in particular antenna gain and transmission power).
  • USB USB 2.0 hi-speed host port for connecting USB printers (USB print server), serial devices (COM-port server) or USB drives (FAT file system)
  • ISDN 1 / 2
    • ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. According to the settings, connect an ISDN cable either to the NTBA or the ISDN terminal device.
    • ISDN 2: Internal (NT) ISDN bus. Use an ISDN cable to connect the ISDN device to the
    • ISDN interface.
  • Analog 1 / 2 / 3 / 4 Use the cables of your analog devices to connect them with the analog interfaces. If necessary use the adapters from the LANCOM Analog Adapter Set.
  • Config (Com) / V.24 Serial configuration interface/COM-port (8-pin mini-DIN): 9,600 – 115,200 baud, suitable for optional connection of analog/GPRS modems. Supports internal COM-port server and provides transparent asynchronous serial-data transfer via TCP.

Package content

  • Manual Quick Reference Guide (DE/EN); Installation Guide (DE/EN)
  • Cable 1 DSL cable for an IP-based line, 4.25 m
  • Adapters 2 TAE adapters (RJ11 – TAE)
  • Antennas 2 LTE / 4G antennas
  • Power adapter External power supply adapter (230 V) 12 V / 2 A DC/S; barrel / bayonet (EU), LANCOM item no. 111303 (not for WW devices)

The additional power LED statuses are displayed in 5-seconds rotation if the device is configured to be managed by the LANCOM Management Cloud.

This product contains separate open-source software components which are subject to their own licenses, in particular the General Public License (GPL). The license information for the device firmware (LCOS) is available on the device‘s WEBconfig interface under “Extras > License information“. If the respective license demands, the source files for the corresponding software components will be made available on a download server upon request.

Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance with Directives 2014/30/EU, 2014/53/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc

LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. This document contains statements relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for technical errors and / or omissions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals