Panel Explanation

LED **Status Explanation**

Monitor

| On (Red)| An alert for system failure due to overheating or wrong voltage.
Off| The device is in normal condition and running normally.
Alert| Blinking (Green)| The power is over (>) 80% watts PoE power budget.
Off| The power is under (<) 80% watts PoE power budget.

SYS

| On (Green)| The switch finishes system booting and the system is ready.
Blinking (Green)| The switch is powered on and starts system booting.
Off| The power is off or the system is not ready / malfunctioning.
PWR| On (Green)| The device is powered on and running normally.
Off| The device is not ready or is failed.

PoE Port 1 ~ 48

| On (Green)| The port is supplied with PoE power.
Off| No PoE power is supplied on the port.

Port 1 ~ 48 (GbE RJ45)

| On (Green)| The device is connected with 1000Mbps.
On (Amber)| The device is connected with 10/100Mbps.
Blinking| The system is sending or receiving data through the port.
Off| The port is disconnected or the link is failed.

Port 49 ~ 54 (SFP+)

| On (Green)| The device is connected with 1000Mbps.
On (Blue)| The device is connected with 10Gbps.
Blinking| The system is sending or receiving data through the port.
Interface Description
RST| Restore the default settings.

Port 1 ~ 48 (PoE)

|

Port 1 to Port 48 can be used for Ethernet connection and PoE connection, depending on the device connected.

Port 49 ~ 54 (SFP+)| Port 49 to Port 54 are used for 10G/1000M fiber connection.

Slide Switch

|

Switch the LED function. Right: PoE connection status.

Left: LAN port connection status.

Console

| Used to perform telnet command control.
 |

Power inlet for AC input (100~240V/AC, 50/60Hz).

Note Power Output —

  • IEEE 3af Max. 15.4W Output Supported
  • IEEE 3at Max. 30W Output Supported PoE Power Budget –-
  • 400 Watts (Max)

Hardware Installation

This section will guide you to install the switch through hardware connection and configure the switch’s settings through web browser.
Before starting to configure the switch, you have to connect your devices correctly.

Network Connection

  • Use a Cat. 5e twisted-pair cable to connect a PoE device to the port (1~48) of this switch.
  • The switch will supply power to PoE Device over the twisted-pair cable.
  • Please note that Power Device must comply with IEEE 802.3af/at.
  • Other PCs, servers and network devices can be connected to the switch using a standard ‘straight through’ twisted pair cable.

DrayTek-VigorSwitch-P2540xs-L2+-Managed-Switch-07

Rack Mounted Installation

The switch can be installed easily by using rack mount kit.

DrayTek-VigorSwitch-P2540xs-L2+-Managed-Switch-09 Software Configuration
DrayTek-VigorSwitch-P2540xs-L2+-Managed-Switch-10 Before using the switch, perform the following steps:

  1. Set up a physical path between the configured the switch and a PC by a qualified UTP Cat. 5e cable with RJ-45 connector.
  2. If a PC directly connects to the switch, you have to setup the same subnet mask for PC and the switch. Default values of the managed switch are listed as follows:
IP Address 192.168.1.224
Subnet Mask 255.255.255.0
DHCP Client Enabled (On)
Username admin
Password admin

After configuring correct IP address on your PC, open your web browser and access switch’s IP address.

The home page of Vigor Switch will be shown as below:

Customer Service

If the switch cannot work correctly after trying many efforts, please contact your dealer for further help right away. For any questions, please feel free to send e-mail to support@draytek.com.

GPL Notice
This DrayTek product uses software partially or completely licensed under the terms of the GNU GENERAL PUBLIC LICENSE. The author of the software does not provide any warranty. A Limited Warranty is offered on Dray Tek products. This Limited Warranty does not cover any software applications or programs.
To download source codes please visit:
http://gplsource.draytek.com
GNU GENERAL PUBLIC LICENSE:
https://gnu.org/licenses/gpl-2.0
Version 2, June 1991
For any question, please feel free to contact DrayTek technical support at
support@draytek.com for further information.

Be a Registered Owner
Web registration is preferred. You can register your Vigor router via
https://myvigor.draytek.com.

Firmware & Tools Updates
Due to the continuous evolution of Dray Teak technology, all switches will be regularly upgraded. Please consult the Dray Tec web site for more information on newest firmware, tools and documents. https://www.draytek.com

We Drayed Corp. , office at No.26, Fishing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan, declare under our sole responsibility that the product.

  • Product name: PoE 48+6 ports 10G up-link Switch
  • Model number: Vigor Switch P2540xs
  • Manufacturer: Dray Tek Corp.
  • Address: No.26, Fishing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan.
    is in conformity with the relevant Union harmonization legislation:
    EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU with reference to the following standards.
Standard Version / Issue date
EN 55032 2015+AC:2016 Class A
EN 61000-3-2 2014 Class A
EN 61000-3-3 2013+A1:2019
EN 55035 2017
EN 62368-1 2014 +A11:2017
EN IEC 63000:2018 2018

Declaration of Conformity

We Dray Tek Corp. , office at No.26, Fishing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan, declare under our sole responsibility that the product.

  • Product name: PoE 48+6 ports 10G up-link Switch
  • Model number: VigorSwitch P2540xs
  • Manufacturer: Drayed Corp.
  • Address: No.26, Fusing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan
  • Importer: CMS Distribution Ltd: Bhola Road, Kiltimagh, Co Mayo, Ireland

is in conformity with the relevant UK Statutory Instruments:
The Electromagnetic Compatibility Regulations 2016 (SI 2016 No.1091), The Electrical Equipment (Safety) Regulations 2016 (SI
2016 No.1101), and The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations
2012 (SI 2012 No. 3032) with reference to the following standards:

Standard Version / Issue date
EN 55032 2015+A1:2016 class A
EN 61000-3-2 2014
EN 61000-3-3 2013+A1:2019
EN 55035 2017
EN 62368-1 2014+A11:2017
EN IEC 63000:2018 2018

Copyrights

© All rights reserved. This publication contains information that is protected by copyright. No part may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without written permission from the copyright holders.

Trademarks
The following trademarks are used in this document:

  • Microsoft is a registered trademark of Microsoft Corp.
  • Windows 7, 8, 10 and Explorer are trademarks of Microsoft Corp.
  • Apple and Mac OS are registered trademarks of Apple Inc.
  • Other products may be trademarks or registered trademarks of their respective manufacturers.

Safety Instructions

Read the installation guide thoroughly before you set up the switch.

  • The switch is a complicated electronic unit that may be repaired only be authorized and qualified personnel. Do not try to open or repair the switch yourself.
  • Do not place the switch in a damp or humid place, e.g. a bathroom.
  • The switch should be used in a sheltered area, within a temperature range of 0 to +45 Celsius.
  • Do not expose the switch to direct sunlight or other heat sources. The housing and electronic components may be damaged by direct sunlight or heat sources.
  • Do not deploy the cable for LAN connection outdoor to prevent electronic shock hazards.
  • Keep the package out of reach of children.
  •  When you want to dispose of the switch, please follow local regulations on conservation of the environment.

Warranty

We warrant to the original end user (purchaser) that the device will be free from any defects in workmanship or materials for a period of two (2) years from the date of purchase from the dealer. Please keep your purchase receipt in a safe place as it serves as proof of date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materials, we will, at our discretion, repair or replace the defective products or components, without charge for either parts or labor, to whatever extent we deem necessary tore- store the product to proper operating condition. Any replacement will consist of a new or re-manufactured functionally equivalent product of equal value, and will be offered solely at our discretion. This warranty will not apply if the product is modified, misused, tampered with, damaged by an act of God, or subjected to abnormal working conditions. The warranty does not cover the bundled or licensed software of other vendors. Defects which do not significantly affect the usability of the product will not be covered by the warranty. We reserve the right to revise the manual and online documentation and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes.

Regulatory Information

Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1.  This device may not cause harmful interference, and
  2. This device may accept any interference received, including interference that may cause undesired operation.

Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment. More update, please visit www.draytek.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals