DrayTek G2100 VigorSwitch L2+ Managed Switch User Guide
- October 30, 2023
- DrayTek
Table of Contents
G2100 VigorSwitch L2+ Managed Switch
Product Information
The VigorSwitch G2100 is a L2+ managed switch designed to provide high-speed connectivity for small to medium-sized businesses. It features 8 RJ45 Ethernet ports and 2 SFP fiber ports, allowing for flexible network configuration. The switch also supports advanced features such as VLAN, QoS, and IGMP snooping, making it ideal for VoIP and video streaming applications. The VigorSwitch G2100 comes with a rack mount kit for easy installation, and is available with power cords suitable for different countries.
Package Content
- VigorSwitch G2100
- Quick Start Guide
- Rack Mount Kit (brackets)
- Console Cable
The type of the power cord depends on the country that the switch will be installed.
- UK-type Power Cord
- EU-type Power Cord
- USA/Taiwan-type Power Cord
- AU/NZ-type Power Cord
If any of these items is found missing or damaged, please contact your local supplier for replacement .
Panel Explanation
LED | Status | Explanation |
---|
RJ 45 LNK/ACT
Port 1 ~ 8
| On (Green)| The device is connected with 1000Mbps.
On (Amber)| The device is connected with 10/100Mbps.
Blinking| The system is sending or receiving data through the port.
Off| The port is disconnected or the link is failed.
Port 9 ~ 10
SFP LNK/ACT
| On (Green)| The device is connected with 1000Mbps.
On (Amber)| The device is connected with 10/100Mbps.
Blinking| The system is sending or receiving data through the port.
Off| The port is disconnected or the link is failed.
SYS
| On (Green)| The switch finishes system booting and the system is ready.
Blinking (Green)| The switch is powered on and starts system booting.
Off| The power is off or the system is not ready / malfunctioning.
PWR
| On| The device is powered on.
Off| The device is powered off.
Interface| | Description
RJ 45 LNK/ACT Port 1 ~ 8| Port 1 to Port 8 can be used for Ethernet
connection.
Console| Used to perform telnet command control.
SFP LNK/ACT Port 9 ~ 10| Port 9 to Port 10 are used for fiber connection.
RST| Factory reset button.
- Press it to reboot the system. (<5 seconds) The SYS LED will blink too.
- Press it to reset the system with factory default settings. (5~20 seconds)
The SYS LED will be off if RST button is pressed between 5 seconds and 10 seconds.
| Power inlet for AC input (100~240V/AC, 50/60Hz).
Hardware Installation
Network Connection
Before starting to configure the device, you have to connect your devices
correctly. A hierarchical net work with minimum levels of devices may reduce
the timing delay between server and client station. Basically, this approach
will minimize the number of devices in any one path; will lower the
possibility of net work loop, and will improve net work efficiency. If more
than two devices are connected in the same net work, select one device as a
Level 1 device and connect all other devices to it at Level 2. Server/ Host is
recommended to connect to the Level 1 device. This is generally if no VLAN or
other special requirements are applied. All device ports are in the same local
area net work.
Rack-Mounted Installation
The switch can be installed easily by using rack mount kit.
1. Fasten t he rack mount kit on both sides of the VigorSwitch using specific
screws.
2. Then, install the VigorSwitch (with rack mount kit ) on t he 19-inch
chassis by using other f our screws.
Software Configuration
Before using the switch, perform t he following steps:
- Set up a physical path bet ween the configured the switch and a PC by a qualified UTP Cat . 5e cable wit h RJ-45 connect or.
If a PC directly connects to the switch, you have to set up the same subnet mask for PC and the switch. Default values of the managed switch are listed as follows:IP Address| 192.168.1.224
---|---
Subnet Mask| 255.255.255.0
DHCP Client| Enabled (On)
Username| admin
Password| admin - After configuring correct IP address on your PC, open your web browser and access switch’s IP address.
The home page of VigorSwitch will be shown as below:
Customer Service
If the switch cannot work correctly after trying many effort s, please contact
your dealer f or further help right away. For any quest ions, please f eel
free t o send e-mail t o support @draytek.com.
GPL Notice
This DrayTek product uses software partially or completely licensed under the
terms of t he GNU GENERAL PUBLIC LICENSE. The author of the soft ware does not
provide any warranty. A Limited Warranty is offered on DrayTek products. This
Limited Warranty does not cover any soft ware applications or programs.
To download source codes please visit : http://gplsource.draytek.com
GNU GENERAL PUBLIC LICENSE:
https://gnu.org/licenses/gpl-2.0
Version 2, June 1991
For any question, please feel free to contact DrayTek technical support at
support @draytek.com for further information.
Be a Registered Owner
Web registration is preferred. You can register your Vigor router via
https://myvigor.draytek.com.
Firmware & Tools Updates
Due to the continuous evolution of DrayTek technology, all switches will be regularly upgraded. Please consult the DrayTek website f or more information on newest firmware, tools and document s. https://www.draytek.com
EU Declaration of Conformity
We DrayTek Corp., office at No.26, Fu Shing Road, HuKou County, Hsin-Chu Industry Park, Hsinchu 300, Taiwan , R.O.C., declare under our sole responsibility that the product
- Product name: 8+2 Gigabit Switch
- Model number: VigorSwitch G2100
- Manufacturer: DrayTek Corp.
- Address: No.26, Fu Shing Road, HuKou County, Hsin-Chu Industry Park, Hsinchu 300, Taiwan.
is in conformity with the relevant Union harmonisation legislation: EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU with reference to the following standards
Standard | Version / Issue date |
---|---|
EN 55032 | 2012+AC:2013 class A |
EN 61000-3-2 | 2014 Class A |
EN 61000-3-3 | 2013 |
EN 55035 | 2017 |
EN 62368-1 | 2014 +A11:2017 (Second |
Edition)
We DrayTek Corp. , office at No.26, Fushing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan, declare under our sole responsibility that the product
- Product name: 8+2 Gigabit Switch
- Model number: VigorSwitch G2100
- Manufacturer: DrayTek Corp.
- Address: No.26, Fushing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan.
- Importer: SEG, 11 Capital Business Park, Borehamwood, Herts, WD6 1GW
is in conformity with the relevant UK Statutory Instruments:
The Electromagnetic Compatibility Regulations 2016 (SI 2016 No.1091), The Electrical Equipment (Safety) Regulations 2016 (SI 2016 No.1101), and The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (SI 2012 No. 3032) with reference to the following standards:
Standard | Version / Issue date |
---|---|
EN 55032 | 2015+A1:2016 class A |
EN 61000-3-2 | 2014 |
EN 61000-3-3 | 2013+A1:2019 |
EN 55024 | 2010+A1:2015 |
EN 62368-1 | 2014+A11:2017 |
EN IEC 63000:2018 | 2018 |
Copyrights
All rights reserved. This publication contains information that is protected
by copyright . No part may be reproduced, transmitted, transcribed, stored in
a ret rieval system, or translated into any language without written
permission from the copyright holders.
Trademarks
The following trademarks are used in this document :
- Microsoft is a registered trademark of Microsoft Corp.
- Windows, Windows 8, 10 and Explorer are trademarks of Microsoft Corp.
- Apple and Mac OS are registered trademarks of Apple Inc.
- Other products may be trademarks or registered trademarks of their respective manufacturers.
Safety Instructions
- Read the installation guide thoroughly before you set up the switch.
- The switch is a complicated electronic unit that may be repaired only be authorized and qualified personnel. Do not try to open or repair the switch yourself .
- Do not place the switch in a damp or humid place, e. g. a bathroom.
- Do not stack the switches.
- The switch should be used in a sheltered area, within a temperature range of 0 t o +45 Celsius.
- Do not expose the switch to direct sunlight or other heat sources. The housing and electronic components may be damaged by direct sunlight or heat sources.
- Do not deploy the cable for LAN connection out door to prevent electronic shock hazards.
- Keep the package out of reach of children.
- When you want t o dispose of the switch, please follow local regulations on conservation of the environment .
Warranty
We warrant to the original end user (purchaser) that the switch will be free from any defects in workmanship or materials for a period of two (2) years from the date of purchase from the dealer. Please keep your purchase receipt in a safe place as it serves as proof of date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and or materials, we will, at our discretion, repair or replace the defective products or components, without charge for either parts or labor, to what ever extent we deem necessary tore- store the product to proper operating condition. Any replacement will consist of a new or re-manufactured functionally equivalent product of equal value, and will be offered solely at our discretion. This warranty will not apply if the product is modified, misused, tampered with, damaged by an act of God, or subjected to abnormal working conditions. The warranty does not cover the bundled or licensed software of other vendors. Defects which do not significantly affect the usability of the product will not be covered by the warranty. We reserve the right to revise the manual and online document at ion and to make changes from time to time in the contents hereof without obligation to not if any person of such revision or changes.
Regulatory Information
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protect ion against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television recept ion, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician f or help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference,
- This device may accept any interference received, including interference that may cause undesired operation.
USA Local Representative
| Company name| ABP International Inc.
---|---|---
Address| 13988 Diplomat Drive Suite 180 Dallas TX 75234
ZIP Code| 75234| E-mail| rmesser@abptech.com
Contact Person| Mr. Robert Messer| Tel.| 19728311600
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment .
References
- GNU General Public License v2.0 - GNU Project - Free Software Foundation
- MyVigor - DrayTek
- Home | DrayTek
Read User Manual Online (PDF format)