DrayTek VigorAP 1060C Powerful Wireless Ceiling Mount AP User Guide
- June 3, 2024
- DrayTek
Table of Contents
VigorAP 1060C Powerful Wireless Ceiling Mount AP
User Guide
VigorAP 1060C
11ax Ceiling AP
Quick Start Guide
VigorAP 1060C Powerful Wireless Ceiling Mount AP
Version: 1.1
Firmware Version: V1.4.0
(For future update, please visit DrayTek web site)
Date: August 9, 2021
Package Content
Take a look at the package content. If there is anything missed or damaged, please contact DrayTek or dealer immediately.
Note
Power Input: 12V 2.5A
PoE Input: 54V 0.6A
Total Rated Power Consumption: 21 Watts
Panel Explanation
LED
| Status|
Explanation
---|---|---
1| On (Blue)| The system is in boot-loader mode.
Off| The system is not ready or fails.
Blinking(Blue)| The system is in TFTP mode.
2| Off| The system is not ready or fails.
Blinking(Blue)| The system is ready and can work normally.
Interface| Explanation
Ethernet Port| Connects to LAN or router.
Supports PoE power & Gigabit (2.5Gbps).
Power Jack(12V 2.5A)| Connecter for a power adapter.
Hole| Explanation
Factory Reset| Restores the unit back to factory default settings. To use,
insert a small item such as an unbent paperclip into the hole. You will feel
the button inside depress gently. Hold it for 5 seconds.
The VigorAP will restart with the factory default configuration and the LED
will blink blue.
Security Hole| A security hole for installing the anti-theft lock.
**** For the sake of security, make the accessory kit away from children.
Intallation
VigorAP can be installed under certain locations: wooden ceiling, plasterboard
ceilings, light-weighted steel frame and wall.
3.1 Ceiling–mount Installation (Wooden Ceiling))
Determine where the Access Point to be placed and mark location on the surface
for the two mounting holes. Use the appropriate drill bit to drill two holes
in the
markings and hammer the bolts into the openings.
- Place the mount base under the wooden ceiling and fasten it on the ceiling with two screws firmly.
- When the mount base is in place, slide the AP into the slot of the mount base.
3.2 Ceilling–mounntt Installation (Plasterboard Ceiling )
- Insert two turnbuckles firmly into the plasterboard.
- Set the Mount Base in the turnbuckles. Let the screws pass through the Mount Base and insert them into the turnbuckles. Fasten them to offer a more powerful supporting force.
- When the Mount Base is in place, slide the mount base into the slot of the AP.
3.3 Suspended Ceiling (Lightweight Steel Frame) Installation
You cannot screw into ceiling tiles as they are weak and not suitable for
bearing loads. Your VigorAP is supplied with mounts (Mount Base) which will be
used to attach directly to the ceiling frame of your suspended ceiling.
-
Slide the mount base into the slot of the AP.
-
Hold the Access Point with one hand to reach the other hand over the T-Rail sides of the bracket.
-
Rotate and hook the stationary end of the ceiling mount base onto the T-Rail ceiling frame.
Note
Warning: The screw set shown below is for wall mounting only. Do not use
such set for ceiling mounting due to the danger of falling.
3.4 Wall–Mounted Installation
For wall-mounting, the VigorAP has keyhole type mounting slots on the
underside.
- Use the appropriate drill bit to drill two holes in the markings and hammer the bolts into the openings.
- Screw the anchors unto the holes until they are flush with the wall; screw the included screws into the anchors.
- Place the Access Point against wall with the mounting screw heads.
****Note
The recommended drill diameter is 6.5mm (1/4″).
Connection and Configuration
4.1 Connect to a Vigor Router using AP Management
Your VigorAP can be used with Vigor routers which support AP management (such
as the Vigor2865 or Vigor2927 series). AP Management enables you to monitor
and manage multiple DrayTek APs from a single interface.
- Connect VigorAP to PoE switch (via LAN port) with Ethernet cable. VigorAP will get the power from the switch directly. Then, connect the VigorSwitch to a Vigor router.
- Access into the web user interface of Vigor router. Here we take Vigor2865 as an example. Open Central Management>>AP>>Status.
- Locate VigorAP 1060C. Click the IP address assigned by Vigor router to access into web user interface of VigorAP 1060C.
- After entering the username and password (admin/admin), the main screen will be displayed.
4.2 Web Configurations
This section will guide you to install the AP and make configuration for
VigorAP.
4.2.1 Connected As a Mesh Node (in Mesh Network)
- Install VigorAP on to the ceiling.
- As a mesh node, settings related to VigorAP 1060C must be configured by a remote Mesh Root (e.g., VigorAP 903) within the mesh network. The user must detect VigorAP 1060C via a Mesh Root to add it as a mesh node.
4.2.2 Connected As an Access Point
As an access point, VigorAP 1060C must be connected to a router and configured
in AP (Access Point) / Range Extender mode.
-
Install VigorAP on to the ceiling.
-
Use a twisted-pair cable with RJ-45 plugs at both ends, and plug into Ethernet device (e.g., Vigor router) and Ethernet port of VigorAP.
-
There are two methods to configure VigorAP.
Method 1:
(a) First, open a web browser on your PC and type https://192.168.1.2. A pop-up window will open to ask for username and password. Note
You may either simply set up your computer to get IP dynamically from the router or set up the IP address of the computer to be in the same subnet as the IP address of
VigorAP 1060C.
• If there is no DHCP server on the network, then VigorAP 1060C will have an IP address of 192.168.1.2.
• If there is DHCP available on the network, then VigorAP 1060C will receive its IP address via the DHCP server.
• If you connect to VigorAP by wireless LAN, you could try to access the web user interface through http://vigorap.com.
(b) After clicking Login, Quick Start Wizard for configuring wireless settings will appear as follows.
(c) Follow the on-screen steps to
finish the network connection.
Method 2:
(a) Use a mobile phone to scan the QR code named with DrayTek Wireless App to
download DrayTek Wireless APP.https://www.draytek.com/products/draytek-wireless
(b) After downloading, run the APP.
(c) Click Quick Start Wizard. Next, scan the QR code named with Connect SSID.
Later, click Connect to access into the APP user interface of VigorAP 1060C to
set the device in AP or Range Extender mode.
Customer Service
If the device cannot work correctly after trying many efforts, please contact
your dealer/DrayTek for further help right away. For any questions, please
feel free to send e-mail to
“support@draytek.com”.
Be a Registered Ownerr
Web registration is preferred. You can register your Vigor router via
https://myvigor.draytek.com.
Firmware & Tools Updates
Due to the continuous evolution of DrayTek technology, all routers will be
regularly upgraded. Please consult the DrayTek web site for more information
on newest firmware, tools and documents. https://www.draytek.com
GPL Notice
This DrayTek product uses software partially or completely licensed under the
terms of the GNU GENERAL PUBLIC LICENSE. The author of the software does not
provide any warranty. A Limited Warranty is offered on DrayTek products. This
Limited Warranty does not cover any software applications or programs.
To download source codes please visit:
http://gplsource.draytek.com
GNU GENERAL PUBLIC LICENSE:
https://gnu.org/licenses/gpl-2.0
Version 2, June 1991
For any question, please feel free to contact DrayTek technical support at
support@draytek.com for further information.
Intellectual Property Rights (IPR) Information
Copyrights
© All rights reserved. This publication contains information that is protected
by copyright. No part may be reproduced, transmitted, transcribed, stored in a
retrieval system, or translated into any language without written permission
from the copyright holders.
Trademarks
The following trademarks are used in this document:
- Microsoft is a registered trademark of Microsoft Corp.
- Windows, Windows 8, 10 and Explorer are trademarks of Microsoft Corp.
- Apple and Mac OS are registered trademarks of Apple Inc.
- Other products may be trademarks or registered trademarks of their respective manufacturers.
Safety Instructions and Approval
- Read the installation guide thoroughly before you set up the device.
- The device is a complicated electronic unit that may be repaired only be authorized and qualified personnel. Do not try to open or repair the device yourself.
- Do not place the device in a damp or humid place, e.g. a bathroom.
- Do not stack the devices.
- The device should be used in a sheltered area, within a temperature range of 0 to +40 Celsius.
- Do not expose the device to direct sunlight or other heat sources. The housing and electronic components may be damaged by direct sunlight or heat sources.
- Do not deploy the cable for LAN connection outdoor to prevent electronic shock hazards.
- Keep the package out of reach of children.
- When you want to dispose of the device, please follow local regulations on conservation of the environment.
We warrant to the original end user (purchaser) that the device will be free
from any defects in workmanship or materials for a period of two (2) years
from the date of urchase from the dealer. Please keep your purchase receipt
in a safe place as it serves as proof of date of purchase. During the warranty
period, and upon proof of purchase, hould the product have indications of
failure due to faulty workmanship and/or materials, we will, at our
discretion, repair or replace the defective products or components, without
charge for either parts or labor, to whatever extent we deem necessary tore-
store the product to proper operating condition. Any replacement will consist
of a new or re-manufactured functionally equivalent product of equal value,
and will be offered solely at our discretion. This warranty will not apply if
the product is modified, misused, tampered with, damaged by an act of God, or
subjected to abnormal working conditions. The warranty does not cover the
bundled or licensed software of other vendors.
Defects which do not significantly affect the usability of the product will
not be covered by the warranty. We reserve the right to revise the manual and
online documentation and to make changes from time to time in the contents
hereof without obligation to notify any person of such revision or changes.
**** Regulatory Information
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device may accept any interference received, including interference that may cause undesired operation.
Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
USA Local Representative
Company name……….. ABP International Inc.
Address ………………………13988 Diplomat Drive Suite 180 Dallas TX 75234
ZIP Code ………………….. 75234
E-mail ………………. rmesser@abptech.com
Contact Person …………….. Mr. Robert Messer
Tel. ……………………. 19728311600
Declaration of Conformity
Hereby, DrayTek Corporation declares that the radio equipment type VigorAP
1060C is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address:
https://www.draytek.com.tw/ftp/VigorAP1060C/Document/CE/
Manufacturer: DrayTek Corp.
Address: No. 26, Fushing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303,
Taiwan
Product: VigorAP 1060C
Frequency Information for Europe area:
2.4G WLAN | 2412MHz – 2472 MHz, max. TX power: 19.86 dBm *1 |
---|---|
5G WLAN | 5150MHz – 5350 MHz, max. TX power: 22.85 dBm; |
5470MHz – 5725 MHz, max. TX power: 28.84 dBm *2
| Requirements in AT/BE/BG/CZ/DZ/DK/EE/FR/DE/IS/IE/IT/EL/ES/ CY/LV/LI/LT/
LU/HU/MT/
NL/NO/PL/PT/RO/SI/SK/TR/FI/SE/CH/HR. 5150MHz~5350MHz is for indoor use only.
(1: for 2.4G WLAN model; 2: for 5G WLAN model)
This product is designed for 2.4GHz and 5GHz WLAN network throughout the EC
region.
Declaration of Conformity
Hereby, DrayTek Corporation declares that the radio equipment type VigorAP
1060C is in compliance with Regulation SI 2017 No. 1206.
The full text of the UKCA Declaration of Conformity is available at the
following internet address:
https://www.draytek.com.tw/ftp/VigorAP1060C/Document/UKCA/
Manufacturer: DrayTek Corp.
Address: No. 26, Fushing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303,
Taiwan
Product: VigorAP 1060C
Importer: SEG, 11 Capital Business Park, Borehamwood, Herts, WD6 1GW
Frequency Information for UK area:
2.4G WLAN | 2412MHz – 2472 MHz, max. TX power: 19.86 dBm *1 |
---|---|
5G WLAN | 5150MHz – 5350 MHz, max. TX power: 22.85 dBm; |
5470MHz – 5725 MHz, max. TX power: 28.84 dBm *2
| Requirements in UK. 5150MHz – 5350MHz is for indoor use only.
(1: for 2.4G WLAN model; 2: for 5G WLAN model)
This product is designed for 2.4GHz and 5GHz WLAN network use in the UK &
Ireland.
Caution
- Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
- Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
- This equipment complies with CE RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
- Operations in the 5.15-5.35GHz band are restricted to indoor usage only.
References
- GNU General Public License v2.0 - GNU Project - Free Software Foundation
- MyVigor - DrayTek
- Home | DrayTek
- Index of /