TUNZE 5000.021 High Jet 12v Pump For Osmolator User Manual
- June 9, 2024
- TUNZE
Table of Contents
- TUNZE 5000.021 High Jet 12v Pump For Osmolator User Manual
- General aspects
- Technical data
- Performance curves (1)
- Safety instructions
- Safety instructions for TUNZE® power supply units
- Power connection to Osmolator
- Connection to water supply
- Servicing / disassembly
- Teileabbildung •Illustration of parts •Illustration des pièces
- Warranty
- [](https://manuals.plus/wp-content/uploads/2023/04/TUNZE-5000.021-High-
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TUNZE 5000.021 High Jet 12v Pump For Osmolator User Manual
General aspects
The Turbelle® High-Jet 5000.021 is a special circulation pump for operation with safety extra-low voltage of 12V on TUNZE® Osmolator® nano 3152 and Osmolator® 3155. It is characterized by a high head, quiet operation, very high reliability and safety with little maintenance.
Technical data
Vmax: 12V DC P: 8.5 W
Pump head hmax: 6.2 m (20’4”)
Flow rate Vmax: 300 l/h (79.25 US gal./h) IPX8 submersion depth: 1.5 m (59”)
Performance curves (1)
1.0 m – 120 l/h (39.4“ – 31.7 US gal.)
1.5 m – 100 l/h (59.1“ – 26.4 US gal.)
2.0 m – 83 l/h (78.8“ – 21.9 US gal.)
Safety instructions
The Turbelle® High-Jet 5000.021 pump is protected against default polarity,
dry running and blockage.
The first time dry running is detected, the pump will stop automatically and
try again after 10 seconds. This should allow the pump to be vented.
If dry running is also detected on the second attempt to start, a third
attempt to start is repeated after 5 minutes.
This ensures an automatic restart after the refill container has been filled.
At the same time, a damaging dry running of the bearings is avoided.
If a blockage is detected, a restart attempt is made every 5 minutes. In this
way, a permanent failure of the refill caused by error detection will be
avoided. There is also an automatic restart in the event of a temporary
blockage, e.g. caused by snails, which resolves itself. The pause times do not
result in dangerous heating and damage to the pump.
Do not operate the metering pump without water or in abrasive suspensions
(e.g. lime water with many particles or sand)!
Do not bend the cable!
Safety instructions for TUNZE® power supply units
TUNZE® power supply units have not been designed for outdoor operation.
In order to prevent water damage, the power supply unit should be placed as
far away from the aquarium as possible.
Operation is permitted only with a residual-current-
operated circuit-breaker fitted, max. 30 mA.
Do not repair a damaged mains cable – replace the unit completely.
The connection to devices, such as electronic switches or speed controllers,
of other makes is not permissible!
Mount the power supply unit in a dry and well-ventilated position only.
Do not mount in the vicinity of heat sources.
Storage conditions: -40°C – +70°C (-40°F – +158°F) 10-95% relative humidity
Operating conditions: 0°C – 45°C (32°F – 113°F) up to 95% relative humidity,
no condensation
This device is suitable for users (including children) with limited physical,
sensorial or mental abilities or without any experience or previous knowledge
only, if a suitable supervision or detailed instructions on the operation of
the device is assured by a responsible person. Please make sure that children
do not play with the device.
Keep the instruction manual in a safe place.
Power connection to Osmolator
First connect the two cables of the Turbelle® High-Jet 5000.021 dosing pump (1) and controller of Osmolator® nano 3152 (2) resp. Osmolator® 3155 (3) with the clamps
(4).Pay attention to the polarity (brown + / blue – ):
- Osmolator®nano 3152 / Controller 4017 (2):
- Blue pump wire (5) on black sheated wire (5a) of Osmolator®nano
- Brown pump wire (6) on black sheathed wire with white dashed line (6a) of Osmolator®nano 3152.
The pump is protected against default polarity and will not start if wired incorrectly!
- Osmolator®3155 / Controller 5017 (3):
- Brown pump wire (7) on black sheated wire (7a) of Osmolator®
- Blue pump wire (8) on black sheathed wire with white dashed line (8a) of Osmolator®
The pump is protected against default polarity and will not start if wired incorrectly!
Connection to water supply
Plug the supplied hose into the plug-in connection (1) of the Turbelle® High-
Jet 5000.021 (3) as far as it will go (2). Check by pulling that it is firmly
locked (4).
Insert the Turbelle® High-Jet 5000.021 pump horizontally in the storage
container (5), lay the hose without kinks for good ventilation and
circulation.
Attach the hose to the edge of the tank with the holder (6).
Servicing / disassembly
Thoroughly clean the entire Turbelle® High-Jet 5000.021 dosing pump as well as
its drive unit at least once a year. In unfavorable conditions, such as high
lime content, heavy sludge accumulation or disturbances, shorter intervals are
necessary.
Unscrew the four stainless steel screws with a (T15) screwdriver (1) and
remove cover (2)
Remove the drive unit with pliers or tweezers (3) and rinse the pump chamber
If the drive unit is fixed due to calcification or dried contaminations, do
not apply force! Soak the pump and drive in a max. 30% vinegar or citric acid
solution for approx. 24 hours, then rinse thoroughly.
Reassemble in reverse order.
Tighten the screws with max. 0.7 Nm (slightly hand-tight).
Teileabbildung •Illustration of parts •Illustration des pièces
| 5000.021| Turbelle ® High Jet
---|---|---
1| 5030.100| Motorblock| Motor block| Bloc moteur
2| 5030.700| Antriebseinheit| Drive unit| Entrainement
3| 5030.600| Kreisellager, O-Ringe, Schrauben| Impeller bearing, O ring seals
and screws| Palier de turbine, joint torique, vis
4| 5030.130| Kreiseldeckel mit O-Ring| Impeller cover with O ring seal|
Couvercle de turbine avec joint torique
5| 5030.200| Anschluss| Connection| Connexion
6| 5030.025| PU-Schlauch, ø6×3,9mm x 3m| PU hose, ø6×3,9mm x 3m (ø0.24”x0.15”
x 118”)| Tuyau PU, ø6×3,9mm x 3m
Warranty
The unit manufactured by TUNZE® Aquarientechnik GmbH carries a limited
guarantee for a period of sixty (60) months after the date of purchase
covering all defects in material and workmanship. Within the framework of the
corresponding laws, your remedies in case of a violation of the guarantee
obligation shall be limited to returning the unit manufactured by TUNZE®
Aquarientechnik GmbH for repair or replacement at the discretion of the
manufacturer. Within the framework of the corresponding laws, the said shall
be the only remedies. Consequential damage and/or other damage shall be
excluded therefrom explicitly. Defect units shall have to be shipped to the
dealer or the manufacturer in the original packaging together with the sales
slip in a pre-paid consignment. Unpaid consignments will not be accepted by
the manufacturer.
Exclusion from guarantee shall exist also in case of damage caused by inexpert
handling (such as water damage), technical modification carried out by the
buyer or by connection to devices which have not been recommended.
Subject to technical modifications, especially those
which further safety and technical progress.
Customers in USA, please refer to seperate Limited
Warranty for United States brochure
[](https://manuals.plus/wp-content/uploads/2023/04/TUNZE-5000.021-High-
Jet-12v-Pump-For-Osmolator-User-Manual_9.png)Disposal
(in keeping with RL2002/96/EU)
The device and the battery may not be disposed of in normal domestic waste; it
has to be disposed of in an expert manner.
Important for Europe: Devices can be disposed of through your community’s
disposal area.
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>