TUNZE 6580 Turbelle Master Stream Instruction Manual
- June 4, 2024
- TUNZE
Table of Contents
TUNZE 6580 Turbelle Master Stream
General aspects
Turbelle® masterstream are high-performance propeller pumps for zoos, research
institutes, rehabilitation clinics or fish farming centers. All parts of the
pumps are 100 percent resistant to corrosion and are made of styrene-
acrylonitrile (SAN) resin and polyoxymethylenes (POM) plastic; the motor axle
is made of titanium alloy; the motor and the electronics are cast in
polyurethane (PU) resin. The innovative microprocessor-controlled permanent
magnet motor has been fitted with an electronic speed control operating on
safety extra-low voltage of 12 V to 24 V. The pumps are ideal for water
circulation, wave action or wave-and-tide simulations. The pump housing serves
as a gigantic intake strainer; thus the pumps do not require an additional
intake strainer. The integrated mounting brackets permit an attachment of the
PVC pipe/rod, diam. 32 mm (1.25 in.), or Magnet Holder 6508.500 (optional).
Notes on the flow rate performance
For propeller pumps with high performance and relatively low water pressure,
it is usually difficult to accurately measure the flow rate performance.
The performance of all our Turbelle® pumps is extensively measured and tested
with ultrasonic methods (2) and a mechanical flowmeter (1). To avoid flow rate
losses, they are connected to a short measurement tube that has a similar
diameter as the pump outlet. To test this method, it is also possible to
perform a volume measurement in a separate container as a comparison, for
lower flow rates up to approx. 10,000 l/h (2,270 USgal./h).
Information based on theoretical propeller calculations or other flow rate
performance measuring methods is therefore not comparable.
Technical data
Turbelle® masterstream 6550
For aquariums of over 5,000 litres (1,320 USgal.)
- Flow rate : 30,000 to about 50,000 l/h (7,900 to 13,000 USgal./h)
- Flow velocity: 0.8 – 1.3 m/s (31.5 – 51 in./sec.)
- Energy consumption: max. 110 W
- Power supply unit: 100–240V / 50–60Hz / 12VDC
- Cable length: 10 m (393.6 in.)
- Dimensions (L x W x H): 340 x 165 x 227 mm (L13.4 x W6.5 x H8.9 in.)
- Ejection: diam. 125 mm (4.9 in.)
- Attachment to pipe: diam. 32 mm (1.25 in.)
Turbelle® masterstream 6580
For aquariums of over 20,000 litres (5,283.4 USgal.) Flow rate: 45,000 to about 80,000 l/h (11,900 to 21,000 USgal./h)
- Flow velocity: 1.1 – 2.0 m/s (43.3 – 78.7 in./sec.)
- Energy consumption: 290 – 420 W
- Power supply unit : 100-240V / 50-60Hz / 24-30VDC
- Cable length : 10 m (393.6 in.)
- Dimensions (L x W x H): 340 x 165 x 227 mm (L13.4 x W6.5 x H8.9 in.)
- Ejection: diam. 125 mm (4.9 in.)
- Attachment to pipe: diam. 32 mm (1.25 in.) Supplied with Turbelle® Controller 7090.
Safety instructions
- Do not operate the pump without water (1).
- Prior to servicing, always put the pump out of operation completely: Risk of injury caused by rotating propeller (2)!
- In the case of swimming pools, models with 12 V technology may be used only!
- The pump must never be used on its own and without precleaner filter in swimming pools; risk of hair entanglement (3)!
- Prior to the initial operation, please check whether the operating voltage corresponds to the main voltage available.
- In order to avoid water damage in the plugs, the mains plug should be fitted at a higher level than the unit (4).
Safety instructions
- Before working in the aquarium, please make sure that all electric units in use have been disconnected from the mains.
- Do not repair a damaged mains cable; instead, replace the motor block completely.
- The temperature of the aquarium water: maximum +35° Celsius (95° F) (5).
- The connection to devices, such as electronic switches or speed controllers, of other makes is not permissible (6).
- Keep the operating instructions in a safe place.
- This device is suitable for users (including children) with limited physical, sensorial or mental abilities or without any experience or previous knowledge only, if a suitable supervision or detailed instructions on the operation of the device is assured by a responsible person. Please make sure that children do not play with the device (7).
Safety instructions for Magnet Holder Very strong magnet! (1)
- Keep the magnet holder and the rotor out of reach of children! Caution! The danger of injury! (2)
- Do not bring the upper and lower magnet parts together directly! Depending on the type, the parts of the magnet cling together on direct contact with about 25 to 50 kg (55 to 110 lbs.) of force.
- Hold the magnet parts on the sides only; never get your hand or fingers between the contract surfaces! (3)
- Attracts metal parts and other magnets with a large force at a distance of below 10 cm (3.9 in.) ! When handling the magnet, no metal parts, other magnets, blades or knives should be located closer than 10 cm (3.9 in.) in order to avoid injuries.
- Exercise caution in case of magnetically sensitive objects, such as pacemakers, data carriers, credit cards and keys – keep a distance of at least 30 cm (11.8 in.)!
- Always use the piece of polystyrene supplied when transporting the Magnet Holder. (4) Heat of more than 50° Celsius (122° F) will lead to the destruction of the magnet or the loss of magnetic force.
Safety instructions for TUNZE® power supply units
- TUNZE® power supply units have not been designed for outdoor operation (1).
- In order to prevent water damage, the power supply unit should be placed as far away from the aquarium as possible. Operation is permitted only with a residual-current-operated circuit-breaker fitted, max. 30 mA.
- Before working in the aquarium, please make sure that all electric units in use have been disconnected from the mains. Do not repair a damaged mains cable – replace the unit completely.
- The connection to devices, such as electronic switches or speed controllers, of other makes is not permissible (2)!The Turbelle® Controller on the pump cable is susceptible to water and may be destroyed in case of water damage! The operation of the Turbelle® master stream is permissible only with the original TUNZE® power supply unit. Mount the power supply unit in a dry and well-ventilated position only.
- Do not mount in the vicinity of heat sources (3). Ambient temperature during operation: 0° Celsius (32° F) to +35° Celsius (95° F)
- Ambient humidity during operation: 30% – 90%Storage temperature: -25° Celsius (-13° F) to +80° Celsius (176° F); Storage humidity: 30% – 95%
Attachment possibilities
On account of the high flow volume, the Turbelle® master stream comes with two mounting brackets for attachment to a PVC pipe or a rod with a diameter of 32 mm (1.25 in.). The brackets are tightened with two corrosion-resistant screws and nuts; thus the flow can be directed very easily and precisely in the tank.
- Attachment to the edge of the tank
- Attachment adjustable in height.
- Attachment with Magnet Holder 6508.500 up to a glass thickness of 30 mm (1 1/8“) (not contained in the scope of delivery; order separately); see Accessories: -Magnet Holder 6508.500).
Initial operation and power supply units
For master stream 6550
- Plug the connector (1) of the power supply unit 6508.120 (2) into the corresponding socket (3) of the pump and subsequently connect the power supply unit to the mains (4). The output of the pump can be set to between 30 percent and 100 percent using the adjusting knob (5).
- Cable Safe master stream 6508.600 (6) protects the TUNZE® plug-in connection against splashing water, especially suitable for the connection of Turbelle® master stream pumps.
- Since the Turbelle® master stream 6550 has an automatic switch-off integrated for safety reasons, it is not suitable for wave box operation/oscillation flow!
- Only model 6580 may be used for wave box operation/oscillation flow!
Initial operation and power supply unit
For master stream 6580
- Turbelle® master stream 6580 uses an industrial power supply unit for installation to DIN rails. It is fitted with robust metal housing, which is shock and vibration-proof, and for this reason suitable for harsh industrial environments.
- Prior to initial operation, the power supply unit has to be installed and connected by an authorized electrician: Mount the power supply unit to a DIN rail in a well-ventilated space. The space has to be waterproof! Wire the input voltage and the earth connection (7). Wire the output voltage to the pump (8), using the cable supplied along with the unit. Observe polarity!
- In some power supply units, the output voltage can be adjusted from 24 V to 28 V (6515.240) (9), for example. The increased voltage will result in increased flow. Please note, that the wattage consumption will increase as well.
Initial operation and power supply units
- Optionally, Turbelle® Controller (11), Multicontroller (12a) or Smart controller (12b) can be attached to the connection of the Turbelle® master stream.
- For more precise information on the connection, please refer to the corresponding instructions for use.
- Automatic shut-off of the pump
- The pumps will be stopped immediately in case of blockage. After the blockage has been removed, the pumps will start up automatically after a delay of 20 seconds. The pump control is thermally protected.
- Automatic shut-off of the power supply unit
- The power supply unit 6508.120 (13) is protected against short-circuit and thermal overload.
- The power supply unit 6515.240 (14) is protected against sustained short circuits, voltage surges and overheating. On account of the high standby capacity, it guarantees reliable start-up, even in case of high starting currents. This switched-mode power supply unit meets the latest EMC standards for industrial environments in keeping with IEC/EN 61204-3.
Servicing
- Prior to servicing, always put the pump out of operation completely, disconnecting it from the power supply unit:
- Risk of injury caused by rotating propeller!
- Thoroughly clean the complete pump and the drive assembly in regular intervals, at least once a year. In case of unfavorable conditions, such as high lime content, strong growth of algae or a lot of mud, shorter intervals may be necessary.
- Open the pump. For this purpose completely unscrew and remove the six stainless steel screws (1); open the propeller housing as shown in illustration (2); and remove the motor block with the cable (3).
- Pull the drive unit out of the motor block (4).
Servicing
- Clean all parts, including the impeller housing (5), the drive assembly (6), the motor block (7) as well as the rotor compartment (8).
- Never use a hard object to remove dirt; use a brush instead (Cleaning Set 0220.700).
- If the drive assembly (6) is too loose and has too much clearance, replace the entire part (see illustration of parts).
- The assembly is carried out in reverse sequence.
Accessories
Magnet Holder 6508.500
- TUNZE® Magnet Holder 6508.500 (1) (patent No. 20 1005 003 170) is used to attach the Turbelle® master stream to panes up to a glass thickness of 30 mm (1.18 in.). It consists of three linked magnetic units with silicon buffer (2). On account of their encapsulated construction, the magnets are resistant to corrosion and cause no harmful effects for the aquarium biotope.
- Attaching self-adhesive elastic buffers on the parts of the magnet holder
- Caution! Prepare magnets separately after each other, and place them far away from each other, as otherwise there is a danger of injury.
- Remove the elastic buffers from the film (3) and press them onto the spot provided for the purpose (4). Use four units for each part of the magnet. As shown in the illustration (5), the adhesive spots are in the round cavities provided for the purpose.
Magnet Holder 6508.500
Pump mounted to magnet holder: Unscrew the propeller housing completely; push the PVC rod of the magnet holder into the mounting bracket (6). Position the second part of the propeller housing (7) and tighten the four screws (8). Turn the pump to the angle required, and tighten the two screws of the mounting bracket (9).
Magnet Holder 6508.500
Attaching to the glass pane:
- We recommend carrying out the mounting work with two people!
- Prepare a suitable position on the glass pane. The glass pane should be free from algae inside the aquarium and should be dry and clean on the outside.
- Position the pump and the magnet holder towards the glass and mount to the aquarium pane (10).
- Hold the outside part of the magnet holder to the inside part (11), and then carefully bring it together.
Magnet Holder 6508.500
- In order to move the magnet holder into another position, the outside magnet should be lifted away from the glass slightly.
- Set the pump according to the requested direction of flow by slightly undoing the fastening brackets.
- The Magnet Holder 6508.500 enables a 90 deg. turn into one direction and 20 deg. turn into the other (13).
Power Supply Box 6515.245
- The power supply box (1) is a control box in keeping with protection standard IP33 (IEC 60529): Protected against solid foreign matter over a diameter of 2.5 mm (.09 in.) and against spray water that is sprayed at an angle of up to 60 deg. to both sides of the vertical.
- This control box is specially made for the power supply units of Turbelle® master stream 6512 and 6515 and is fitted with a lateral master switch (2), a high-quality fan (3), and a DIN rail (4).
- Dimensions : 375 x 375 x 225 mm (L14.8 x W14.8 x H8.9 in.).
Power Supply
Mounting the power supply unit:
- Observe the safety instructions for TUNZE® power supply unit!
- Commission an electrician for the installation and servicing work!
- Attach the power supply unit in the power supply box to the DIN rail (5); up to two power supply units can be fitted in one box.
- Use the circuit diagram (6) to wire the power supply unit up to the master switch and the fan.
- Wire the output voltage to the pump, using the Pump Cable 6515.246 supplied along with the unit. Observe polarity!
- Use the transparent lid to close the box, and lock using a screwdriver (7).
Caution! The power supply box must never be connected up to the mains in open condition !
Illustration of parts
List of spares
| 6550.000| 6580.000| | Turbelle ® masterstream|
---|---|---|---|---|---
1| 6508.100| 6515.100| Motorblock| Motor block| Bloc moteur
2| 6508.130| 6508.130| Propellergehäuse| Propeller housing| Corps de pompe
3| 6508.134| 6508.134| Schrauben Set M6| M6 screw set| Set de vis M6
4| 6508.700| 6508.700| Antriebseinheit| Drive unit| Entraînement
5| 6515.101| 6515.101| O-Ring 110 x 5mm| O-ring seal 110 x 5mm| Joint torique
110 x 5mm
6| 6508.120| | Netzteil 12V DC| 12 VDC power supply unit| Alimentation 12V DC
7| | 6515.240| Netzteil 24-28V DC| 24-28 VDC power supply unit| Alimentation
24-28V DC
8| | 7090.500| Turbelle® controller provided| Turbelle® controller provided|
Turbelle® controller provided
8a| | 7090.103| Schutzkappe16mm| Protective cap 16mm (0.63 in.)| Obturateur
16mm
8b| | 7090.400| Wandhalter für Controller| Wall mount for controller| Support
mural pour Controller
8c| | 7090.102| 3 Drehknöpfe für Controller| 3 rotary knobs for controller| 3
boutons pour Controller
9| | 6515.246| DC Pumpenkabel 5m| DC pump cable 5 m (196.8 in.)| Câble de
pompe 5m DC
10| 6508.600| 6508.600| Cable Safe masterstream| Cable Safe masterstream|
Cable Safe masterstream
Warranty
The unit manufactured by TUNZE® Aquarientechnik GmbH carries a limited
guarantee for a period of sixty (60) months after the date of purchase
covering all defects in material and workmanship. Within the framework of the
corresponding laws, your remedies in case of a violation of the guarantee
obligation shall be limited to returning the unit manufactured by TUNZE®
Aquarientechnik GmbH for repair or replacement at the discretion of the
manufacturer. Within the framework of the corresponding laws, the said shall
be the only remedies. Consequential damage and/or other damage shall be
excluded therefrom explicitly. Defect units shall have to be shipped to the
dealer or the manufacturer in the original packaging together with the sales
slip in a pre-paid consignment. Unpaid consignments will not be accepted by
the manufacturer.
Exclusion from guarantee shall exist also in case of damage caused by inexpert
handling (such as water damage), technical modification carried out by the
buyer or by connection to devices which have not been recommended. Subject to
technical modifications, especially those which further safety and technical
progress. Customers in USA, please refer to seperate Limited Warranty for
United States brochure.
Disposal
(in keeping with RL2002/96/EU) The device and the battery may not be disposed
of in normal domestic waste; it has to be disposed of in an expert manner.
Important for Europe: Devices can be disposed of through your community’s
disposal area.
TUNZE® Aquarientechnik GmbH Seeshaupter Straße 68
82377 Penzberg
Germany Tel : +49 8856 2022
Fax : +49 8856 2021
info@tunze.com
www.tunze.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>