WLA-2 LED Area Light
Product Manual
WLA-2 LED Area Light for Industrial Work Cells
- Designed for illuminating industrial work cells and in areas with exposure to liquid, such as food and beverage processing applications
- An LED-dense array with high output ideal for area lighting, machine lighting, and machine vision
- Illuminates a large area with an even pattern of light and no shadows
- Rugged thermoplastic housing rated to IP69K per DIN 40050-9 for heavy duty washdown
- Encapsulated housing option rated IP68 for prolonged exposure to water and submersion
- Lensed models available for intense, close-range inspection or long-range projection
- Available in four sizes
For PWM dimming, use with the LC15T-127AP1RBGQP dimmer module. For more information, refer to the LC15T In-Line Touch Switch datasheet, p/n 217460.
Important: Read the following instructions before operating the light. Please download the complete WLA-2 Area Light technical documentation, available in multiple languages, from www.bannerengineering.com for details on the proper use, applications, Warnings, and installation instructions of this device.
Models
Standard models shown. Contact factory for other options. Other colors are available by request.
- No lens option on encapsulated or diffuse window models
** No warm white option on encapsulated models
Wiring Diagram
Male | Pin | Wire Color | Connection |
---|---|---|---|
1 | Brown | 12 V DC to 30 V DC | |
3 | Blue | DC common | |
4 | Black | High/Low/Off Models: |
Connect to 12 V DC to 30 V DC for 50% maximum intensity. For maximum
intensity, leave the black wire floating or connected to common.
PWM Models:
Pulse width modulation (PWM) input. For maximum intensity, leave the black
wire
floating or connected to common. Connecting to 12 V DC to 30 V DC causes the
LEDs to shut off.
2| White| Not used
Specifications
Supply Voltage
12 V DC to 30 V DC
Use only with suitable Class 2 power supply (UL) or SELV power supply (CE).
See electrical characteristics on product label
Supply Current
Housing Length (mm) Max Current (A) | Typical Current Draw (A) |
---|---|
12 VDC | 24 VDC |
105 | 0.875 |
190 | 1.750 |
275 | 3. |
360 | 3.500 |
Construction
Standard models: PBT housing, polycarbonate window, nickel-plated brass
connector
Encapsulated models: PBT housing, nickel-plated brass connector, polyurethane
encapsulated
Connections
Integral 4-pin M12 male quick-disconnect connector (4-pin connecting cordset
required)
LED Lifetime
Lumen Maintenance – L70
When operating within specifications, output will decrease less than 30% after
70,000 hours.
Dimming
High/Low/Off Models: 100/50/0% intensity, dependent on wiring
PWM Models: Compatible with PWM LED dimming, dimmable to 5% intensity
Pulse Width Modulation (PWM):
Frequency: Up to 1000 Hz
Voltage: 12 V DC to 30 V DC
Current: 4 mA max.
Vibration and Mechanical Shock
Vibration: Vibration: 10 Hz to 55 Hz, 1.0 mm peak-to-peak amplitude per IEC
60068-2-6
Shock: Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27
Impact: IK07 (IEC 60068-2-75)
Certifications
Banner Engineering BV
Park Lane, Culliganlaan 2F
bus 3, 1831 Diegem, BELGIUM
Turck Banner LTD Blenheim
House, Blenheim Court,
Wickford, Essex SS11 8YT,
Great Britain
Operating Temperature
Clear and Diffuse Window Models: –40 °C to +70 °C (–40 °F to +158 °F)
Light output begins to decrease above 50 °C (122 °F), and decreases to
approximately 65% of max intensity
Encapsulated Models: –20 °C to +50 °C (–4 °F to +122 °F)
Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Mounting
(4) integrated M5 × 1 threads in housing. No hardware provided. Optional
mounting brackets are available (see Accessories)
Note: When mounting the light to combustible or insulating surfaces, a minimum of 1 inch of clearance around all sides is suggested. Optional standoffs or an alternative mounting method to achieve spacing.
Environmental Rating
Suitable for wet locations per UL 2108
Clear and Diffuse Window Models: Rated IP67 and IP69K per DIN 40050-9
Encapsulated Models: Rated IP67, IP68, and IP69K per DIN 40050-9
Required Overcurrent Protection
WARNING: Electrical connections must be made by qualified personnel in
accordance with local and national electrical codes and regulations.
Overcurrent protection is required to be provided by end product application
per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
www.bannerengineering.com.
Supply Wiring (AWG) | Required Overcurrent Protection (Amps) |
---|---|
20 | 5 |
22 | 3 |
24 | 2 |
26 | 1 |
28 | 0.8 |
30 | 0.5 |
Light Characteristics
Daylight White Efficacy: up to 131 lumens/watt typical at 24 V AC at 25 °C (77
°F)1
CRI: 80, minimum
Color| Color Temperature
(CCT)2| Size
---|---|---
105| 109| 275| 360
Daylight White| 5000K (± 300K)| 1025| 2050| 3075| 4100
Warm White| 3000K (± 200K)
- Lumen values are reduced by 20% on diffused window models.
- The color temperature of encapsulated models is 4500K (±300K).
Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise.
Model | L1 | L2 |
---|---|---|
WLA-2..105X | 105.1 mm (4.14 in) | 92.8 mm (3.66 in) |
WLA-2..190X | 188.9 mm (7.44 in) | 176.7 mm (6.96 in) |
WLA-2..275X | 272.7 mm (10.74 in) | 260.3 mm (10.25 in) |
WLA-2..360X | 356.6 mm (14.04 in) | 344.3 mm (13.55 in) |
Photometric Data
Optional data shown below are for cool white models with a clear window only. To get lux and candela values for models with a diffuse window and/or other colors, multiply the values shown on the charts by the following factors:
Warm White | Green | Red | Yellow | Blue |
---|---|---|---|---|
1 | 1 | 0.43 | 1 | 0.29 |
Clear Window, No Lens
Clear Window, L30
Diffuse Window, No Lens
Accessories
Cordsets
4-Pin Threaded M12 Cordsets—Single Ended
Model | Length | Style | Dimensions | Pinout (Female) |
---|---|---|---|---|
MQDC-406 | 2 m (6.56 ft) | Straight |
2 = White
3 = Blue
4 = Black
5 = Unused
MQDC-415| 5 m (16.4 ft)
MQDC-430| 9 m (29.5 ft)
MQDC-450| 15 m (49.2 ft)
MQDC-406RA| 2 m (6.56 ft)| Right-Angle| |
MQDC-415RA| 5 m (16.4 ft)
MQDC-430RA| 9 m (29.5 ft)
MQDC-450RA| 15 m (49.2 ft)
Brackets
SMBBSSM| | SMBBSRA|
---|---|---|---
• 316 stainless steel bracket and hardware
• Includes 2 brackets; four M5
socket drive, button head screws to attach to light| | • 316 stainless steel
bracket
and hardware
• Right-angle swivel bracket
for versatile orientation|
SMBWLAMAG| | ACC-WLA STANDOFFS|
• Kit includes four magnets, four M5 phillips head screws, and two M5 nuts
with lock rings
• ø = 51.8 mm (2.04 in)| | • Kit includes two nylon spacers, two M5 phillips
head screws, and two M5 nuts with lock rings
• Inner diameter = 5.56 mm (0.22 in), outer diameter = 12.7 mm (0.50 in),
length = 25.4 mm (1.00 in)|
Dimmers
LC15T Series | LC65P1T |
---|
• LC15T-127AL2RGQP model with On/Off control and illuminated indication
• LC15T-127AP1RBGQP model with On/Off/Dimming control and illuminated
indication
• In-line capacitive touch switch with M12 connectors
• Rated for up to 30 V DC and 4 A maximum output current
• Rugged and waterproof IP67 housing
| • Potentiometer with terminal and M12 connector options
• PWM control
• Rated for up to 30 V DC and 4 A maximum output current
• Unsealed IP20 housing
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in
material and workmanship for one year following the date of shipment. Banner
Engineering Corp. will repair or replace, free of charge, any product of its
manufacture which, at the time it is returned to the factory, is found to have
been defective during the warranty period. This warranty does not cover damage
or liability for misuse, abuse, or the improper application or installation of
the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER
EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING
UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of
Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING
CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS,
EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE
THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT
LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the
design of the product without assuming any obligations or liabilities relating
to any product previously manufactured by Banner Engineering Corp. Any misuse,
abuse, or improper application or installation of this product or use of the
product for personal protection applications when the product is identified as
not intended for such purposes will void the product warranty. Any
modifications to this product without prior express approval by Banner
Engineering Corp will void the product warranties. All specifications
published in this document are subject to change; Banner reserves the right to
modify product specifications or update documentation at any time.
Specifications and product information in English supersede that which is
provided in any other language.
For the most recent version of any documentation, refer to:
www.bannerengineering.com.
For patent information, see
www.bannerengineering.com/patents.
FCC Part 15 Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Industry Canada
This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the
following two conditions: 1) This device may not cause harmful interference;
and 2) This device must accept any interference received, including
interference that may cause undesired operation.
Mexican Importer
Banner Engineering de Mèxico, S. de R.L. de C.V.
David Alfaro Siqueiros 103 Piso 2 Valle oriente San Pedro Garza Garcia Nuevo
Leòn, C. P. 66269 81 8363.2714
©Banner Engineering Corp. All rights reserved
www.bannerengineering.com – Tel: + 1 888
373 6767
P/N 232665 Rev. A
References
- info.bannerengineering.com/cs/idcplg?IdcService=GET_FILE&dDocName=217460&RevisionSelectionMethod=Latest&Rendition=web
- Patents
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>