The SI-CA 030 Flue Gas Analyzer is a portable device that measures the concentration of CO and CO2 in the flue gas of combustion equipment. It also measures air and flue gas temperatures, and pressure, and calculates relevant combustion parameters.

The device is not designed for continuous operations and/or use as a control/alarm system. It is recommended to keep the instrument at a distance of at least 25 cm (10) away from mechanical watches, pacemakers, defibrillators, and other devices are proven sensitive to magnetic fields.

Analyzer Description

The following components are included in the analyzer:

  1. Min-DIN connection for CO and CO2 probe
  2. Thermocouple connection for air temperature
  3. Thermocouple connection for flue gas temperature
  4. P- connection
  5. P+ connection
  6. Gas connection
  7. USB connection

Product Usage Instructions

  • These operating instructions describe the basic handling of the device.
  • Please refer to the operating instructions available at www.sauermanngroup.com for safe use of the product and detailed information.
  • Do not give this device to a child.
  • The magnets in the back of the instrument can damage credit cards, hard drives, mechanical watches, pacemakers, defibrillators, and other devices are proven sensitive to magnetic fields. It is recommended to keep the instrument at a distance of at least 25 cm (10”) away from any of these devices.
  • These gas analyzers are designed to measure flue gases exhausted from combustion equipment. They are not designed for continuous operations and/or use as a control/alarm systemsauermann-SI-CA-030-Gas-Residential-Combustion-Analyzer-Kit-fig- \(1\)

Before Using the Flue Gas Analyzer

It is recommended to keep the instrument at a distance of at least 25 cm (10) away from mechanical watches, pacemakers, defibrillators, and other devices are proven sensitive to magnetic fields. The device is not designed for continuous operations and/or use as a control/alarm system.

WARNING!

  • Be sure all connections are tight to assure accurate sampling.
  • When conducting measurements, the water trap/filter assembly MUST be in a VERTICAL position.sauermann-SI-CA-030-Gas-Residential-Combustion-Analyzer-Kit-fig- \(2\)

When testing is completed, always drain any accumulated condensation inside the water trap (after EVERY test!). The condensate be slightly acidic, so avoid contact with skin and make sure the condensate does not leak out of the water trap.

Analyzers description

  1. Min-DIN connection for CO and CO2 probe
  2. Thermocouple connection for air temperature
  3. Thermocouple connection for flue gas temperature
  4. P- connection
  5. P+ connection
  6. Gas connection
  7. USB connection

Operating temperature protection and information about storage

Operating temperature, protection of the instruments, and information about storage

  • Operating temperature: from -5 to 45 °C (23 to 113 °F)
  • Protection: IP42

If the instrument is stored outside the operating temperature (for example in a van, a warehouse,…) please let the analyzer acclimate to room temperature for at least 15 minutes before starting and operating the analyzer. If the ambient temperature is lower than 10 °C (50 °F), the analyzer should be acclimated to ambient temperature before performing measurements.

First Start-up

DO NOT insert the gas probe in the flue/chimney/stack. Keep pressed for 3 seconds to turn on the analyzer.

  • Press the Down key to go to Start and then press OK.
  • Select your country by pressing the Up and Down keys and validate with OK.
  • Select your language by pressing the Up and Down keys and validate with OK.
  • Set the date by pressing OK on each line, use Up and Down keys to select the correct item and validate with OK then go to Next.
  • Set the time by pressing OK on each line, use Up and Down keys to select the correct item and validate with OK then go to Next.
  • Set your time zone by pressing OK on each line, use Up and Down keys to select the correct item and validate with OK then go to Next.
  • Select if you want your pump turned ON or OFF after Auto-Zero pressing OK then go to Save.
  • Autozero is in progess.
  • The probe can be inserted in the chimney. The analyzer displays the measurements.
  • DO NOT insert the gas probe in the flue/chimney/stack.
  • Keep the power button pressed for 3 seconds to turn on the analyzer.

On/Off

  • During autozero, DO NOT insert the gas probe in the chimney.

Keep the power button pressed for 3 seconds to turn it on/off the analyzer. During autozero, DO NOT insert the gas probe in the chimney. Once the autozero is finished, insert the gas probe in the chimney, and gas measurements are displayed. Before powering off, disconnect the hoses from the analyzer and empty and dry the water trap.

  • Keep pressed for 3 seconds to turn on the analyzer. Once the autozero is finished, insert the gas probe in the chimney, and gas measurements are displayed.
  • Keep pressing for 3 seconds to turn off the analyzer. Before powering off, disconnect the hoses from the analyzer and empty and dry the water trap.

Stop/Restart the Pump

  • Press “Main Menu” key.
  • Press OK on “Pump” line to activate or deactivate the pump.

Combustion Analysis, Saving & Printing

Before proceeding with the combustion analysis, remember to set the proper fuel.

  1. Go to Settings and press OK.
  2. Go to Analysis and press OK.
  3. Press OK on Fuels line.
  4. Scroll through the fuels and press OK on the required one.
  5. Once the required fuel is selected, press the “Main Menu” key until the main menu is displayed, and press OK on the “Gas analysis” line.
  6. Press Main Menu key until the main menu is displayed and press OK on Gas analysis line.
  7. Measurements of the gas analysis are displayed.

You can also quickly access the fuel selection menu via the fuel shown at the top of the combustion gas analysis screen.

  • To view the different measured parameters, use the Up and Down keys to scroll through the various parameters.
  • To save combustion data, please use the Sauermann Combustion mobile phone app.
  • To print, the results, use the Wireless Printer available as an option.

The Sauermann Combustion app lets you control your Si-CA analyzer remotely, view measurement results in real-time, and customize them before exporting in the format of your choice.sauermann-SI-CA-030-Gas-Residential-Combustion-
Analyzer-Kit-fig- \(25\)

Download the Sauermann Combustion App

Download the Sauermann Combustion Software

Download the full manual

Monitoring Configuration Emissions Measurement on Boilers, Engines & Other Applications sauermann-SI-CA-030-Gas-Residential-Combustion-Analyzer-Kit-
fig- \(31\)

Customer service portal
Use our Customer service portal to contact us

www.sauermanngroup.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals