RAIN HARVESTING FFBO02 First Flush Boost Expansion Kit Installation Guide

June 10, 2024
Rain Harvesting

RAIN HARVESTING FFBO02 First Flush Boost Expansion Kit Installation Guide
RAIN HARVESTING FFBO02 First Flush Boost Expansion
Kit

PRODUCT DETAILS
The Expansion kit is specially designed for the First Flush Boost to increase your diversion volume by 20L (5gal) at a time.

You can install up to two of them, to bring your total diversion volume to 40L (10gal) or 60L (15gal)

Code Size Country
FFBO02 100mm Australia
FFBO02 4″ USA
FFBO02 100mm New Zealand
FFBO02 110mm UK
FFBO02 110mm South Africa
FFBO02 110mm Europe

Installation

WHAT’S IN THE BOX?

First Flush Boost Expansion Kit:

  • First Flush Boost Body
  • First Flush Boost Joiner

TOOLS/MATERIALS YOU MAY REQUIRE

  • Tape measure
  • Marker pen
  • Saw
  • Solvent weld glue
  • Screws
  • Drill or screwdriver

INSTALLATION – FIRST FLUSH BOOST EXPANSION KIT

  1. If you’re installing your Expansion Kit onto an already installed First Flush Boost, you will need to make sure your chamber has been drained of water. You will also need to remove the exit funnel and Slow Release Valve.
  2. Whilst supporting the First Flush Boost Body, remove the wall brackets.
  3. Using priming fluid, clean the gluing surfaces of the new Boost Body and the Joiner, as well as the bottom gluing surface of the existing First Flush Boost Body.
  4. Apply solvent weld glue to the bottom side of the Boost Joiner and new Boost Body. Bring the two together ensuring the join is fully seated and hold until firm.
  5. Apply solvent weld glue to the top side of the Boost Joiner and the bottom gluing surface of the existing Boost Body. Bring the two together ensuring the join is fully seated and hold until firm.
  6. Re-install the wall brackets at the base of the new Boost Body.
  7. Re install the transparent exit funnel with o ring, filters, and Slow Release Valve on the threaded outlet of the new Boost Body.

Product Specifications

First Flush Boost Expansion Kit
Product Overawe

Dimensions & Pipe Fittings 

COUNTRY CODE A Pipe Fitment B C D
Australia & New Zealand FFBO02 100F 354 260 345
USA FFBO02 4″ SCH40 F 13.94″ 10.24″ 13.58″
UK, South Africa & Europe FFBO02 110 F 354 260 345

All dimensions are in mm unless otherwise stated

Fitting guide:
F = Female / Socket Fitting
M = Male / Spigot Fitting (Pipe size)
IP = In-Pipe Fitting

Maintenance

It’s important to ensure that your first flush diverter outlet remains clear of any debris. If your outlet becomes blocked, the chamber will not empty and the first flush of water will not be diverted when it rains.

To ensure the flow of water out through your Slow Release Valve, periodically remove from the Transparent

Rapid Release Exit Funnel to check for any build-up of matter. Remove filters, and clean if required.

For best results and minimal maintenance, rain heads with 0.955mm aperture mesh such as Leaf Eater Rain

Heads must be installed upstream of the First Flush Boost to limit the entry of debris that can reach your diverter.

A common misconception about collecting rainwater is that all you need is a roof, a tank and some rain. This ‘tanking’ approach cannot always be relied on to deliver the volume – or quality – of water that you require. That is where we can help.

With some thought, your rain harvesting system can provide you with cleaner water and lots of it. Whether you’re completely reliant on tank water or wanting to keep the garden green, our simple steps will help you achieve your goal.

The Rain Harvesting approach to rainwater collection involves using tested and proven products to make quality rainwater available for use in and around your property. You don’t need much to get started and you will be surprised how easy it is to get the most out of your rainwater system.

How can we help you?

DISCLAIMER This product specification is not a complete guide to product usage. Further information is available from Rain Harvesting Pty Ltd and from the Installation and Operating Instructions. This specification sheet must be read in conjunction with the Installation and Operating Instructions and all applicable statutory requirement. Product specifications may change without notice. © Rain Harvesting Pty Ltd

For more information or to find out
how we can help, just give us a call on
+61 7 3248 9600
Or visit our website at
rainharvesting.com

RAIN HARVESTING Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Rain Harvesting User Manuals

Related Manuals