NexTrend E600WA Peverse Osmosis Water Filtration System User Manual
- May 15, 2024
- NexTrend
Table of Contents
- Safety Notice
- Required Tools (Not included)
- In the Box
- Product Overview
- Sample Connection
- Tips Before Installation
- Installation
- Connect the Tubes
- Start Up the System
- Indicators & Display
- Filter Replacement Guide
- Specifications
- Customer Service
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NexTrend E600WA Peverse Osmosis Water Filtration System User Manual
Safety Notice
- Only use the power adapter with the rated voltage.
- For long-time storage, shut off the feed water adapter and unplug the power adapter.
- After a long period of non-use, follow the instructions for the first use.
- In case of leaks, failures, or other abnormalities, disconnect the power and contact us.
- To prevent damage or leaks, do not disassemble the machine.
- Only use municipal water as the source.
Required Tools (Not included)
-
Variable speed drill
-
Drill bit: 1/4″ (for drainpipe) 1″ (for faucet hole)
-
Adjustable Wrench
-
Phillips Screwdriver
-
Utility knife
-
Flashlight
-
Towel
In the Box
-
System Housing with Filters*1
-
Smart Faucet Spout*1
-
Faucet Body*1
-
Feed Water Adapter*1 Set
-
1/4″ Filtered Water Tube*1
-
1/4″ Waste Water Tube*1
-
Drain Saddle*1 Set
-
Gasket*2
-
Lock Clip*5
-
Nut*1
-
Non-slip Gloves*1
-
Teflon Tape*2
-
Power Adapter*1
-
User Manual*1
Product Overview
- Smart Faucet Port
- Power Port
- Inlet Water Port
- Filtered Water Outlet
- Waste Water Outlet
Sample Connection
A-B, From Feed Water Adapter to Inlet Water Port
C-D, From RO faucet to Filtered Water Outlet
E—F, From Drain Saddle to Waste Water Outlet
G—H, From Faucet Power Cord to Faucet Port
(1- >), From Power Port to Power Socket
Tips Before Installation
Attention: Don’t pull out the tube directly. This will damage the joint and cause leakage.
To Connect
-
Insert the tube
-
Gently pull the plastic ring of the port/quick connector to leave a slot.
-
Insert the blue lock clip to secure the connection.
To Disconnect
-
Remove the blue lock clip from the joint.
-
Press the plastic ring of the port.
-
Gently pull out the tube from the port or quick connector.
Installation
Install the Feed Water Adapter (3/8″ or 1/2″)
-
Shut off the cold water supply valve under the sink. Turn on the kitchen faucet to release the water pressure.
-
Disconnect the cold water pipe of the kitchen faucet from the cold water supply valve.
-
To prevent water leakage, please apply several rounds of Teflon tape to the cold water supply valve and the threaded end of the feed water adapter.
-
Twist the feed water adapter onto the cold water supply valve and tighten it with wrench.
Note: If the cold water pipe is 1/2″, unscrew the two converters from the feed water adapter, and then implement Step 4. -
Twist the cold water pipe onto the feed water adapter and tighten it with a wrench.
Install the Filters
-
Take out the filters and remove the wrappings from the top of each filter.
-
Insert each filter horizontally into its corresponding slot (RO filter: top,
CB filter: middle, CF filter: bottom). -
Clockwise twist the filter with a little force for 90 degrees, until the top circle is aligned with the solid circle on the top of the slot.
Note: To avoid water leakage, the filters should fit snugly into the
system.
Install the RO Faucet
Note : If your kitchen sink or countertop does not have an existing hole, you will need to drill one ( hole diameter: 1 inch ). A reference sticker is provided to help you drill the hole.
- Insert the faucet spout into the faucet body.
- Slip on the gasket.
- Insert the faucet into the hole on the kitchen or countertop.
- Under the sink, slip on and tighten the gasket and nut.
Note: Slip on the parts in the order shown in the picture.
Install the Drain Saddle
- Paste the foam seal provided to the inside of the drain saddle. Make sure the hole of foam seal is aligned with the hole of drain saddle. Choose a spot on the vertical drainpipe for installing the drain saddle.
- Drill a 1/4 inch hole in the drainpipe. Be sure not to penetrate the opposite side of
- Slip the drain saddle on one end of the red tube, and insert the red tube into the drilled hole on thedrainpipe.
- Secure the drain saddle on the drainpipe by tightening the screws and nuts while leaving the tube in the hole.
- Secure the tube in place with a lock clip.
Connect the Tubes
Attention:
- Make sure the tubes are fully inserted until you reach the mark on the tube. If the tubes are not fully inserted, no seal will be created and leakage will occur.
- Always use the lock clips to secure the connections.
- It’s not recommended to cut the tubes. But if the tube is too long, cut it to a suitable length with a utility knife. Cut the tube squarely and cleanly. The cuts must be neat.
Connect the Inlet Water Tube
- Identify the white inlet water tube which has been attached to the feed water adapter.
- Insert the other end into the inlet water port, then gently pull the plastic ring of the port to leave a slot and secure the tube with a lock clip.
Connect the Filtered Water Tube
- Connect one end of the white filtered water tube with the quick connector, then secure the connection with a lock clip.
- Insert the other end into the filtered water outlet marked “Drinking Faucet” on the top of the system, then secure the tube with a lock clip.
- Insert the faucet power cord into the Faucet Power port and tighten the nut.
Connect the Waste Water Tube
- Identify the red waste water tube which has been attached to the drain saddle.
- Insert the other end into the waste water outlet marked “Drain” on the top of the system, then use a lock clip to secure the connection.
Start Up the System
- Turn on the cold water supply valve and feeder water adapter. Check and make sure no water leakage at joints, fittings, valves, and tube connections.
- Plug in the power adapter, the system starts flushing the RO membrane for 5 minutes. On the system housing, the filter indicators (CF/CB/RO) stay solid blue, while the water quality indicator flashes red.
- Run the RO faucet for 30 minutes until the TDS value on the faucet screen is below 100, the water is drinkable. On the system housing, the filter indicators (CF/CB/RO) stay solid blue, while the water quality indicator flashes (Blue: Good, purple: Fair, red: bad) based on real-time inlet water quality.
Note: During flushing, the water is not drinkable. The flushing time
accumulates, so if you stop the flushing early, the system will resume
flushing when you open the RO faucet until it reaches a total of 30 minutes.
Indicators & Display
Filter Life Indicator
Monitor the filter indicator and replace the corresponding filter.
Indicator Color| Buzzer Status| Remaining Filter Life (Day)|
Water Treatment Capacity (L)
---|---|---|---
Steady Blue| /| >15| >150
Steady Purple| Beeps 2 times when dispensing Water| <15| >150
Steady Red| Keeps beeping when dispensing Water| <0| <0
Inlet Water Quality Indicator
Indicator Color | Inlet Water [sJTE113% |
---|---|
Blue | Good |
Purple | Fair |
Red | poor |
RO Faucet Display
Machine Status | Display Status |
---|---|
The faucet is powered on | Show 888 for 2 seconds |
The faucet is dispensing water | Show filtered water TDS value (Drinkable: TDS |
Flushing the filters | |
Machine Malfunction | E02 / EO3 / E04 / EO5 |
Filter Replacement Guide
Notes:
- The filter life is for reference only, as the filter life varies with the source water quality and usage frequency.
- To ensure the quality of drinking water, please monitor thefilter indicators and replace the corresponding filter.
- For continued water filtration and optimum system performance, only use genuine NexTrend filter replacements.
How to Replace the Filters
- Twist off the old filter in a counterclockwise direction.
- Remove the packaging from the new filter.
- Insert the new filter into the corresponding slot and twist it clockwise to secure itin place.
- After replacement, reset the filter life indicator first and then flush the filter.
How to Reset the Filter Life Indicator
To reset the filter life, touch and hold the red filter indicator for 5 seconds, it turns solid blue and the buzzer beeps once.
Note: Each filter’s life indicator cannot be reset simultaneously and requires individual resetting one by one.
Touch and hold for 5s
How to Flush the New Filters after Replacement
After replacing the filter and resetting the corresponding filter indicator
CF filter: Turn on the RO faucet to flush for 5 minutes, the water
quality indicator flashes red.
CB filter: Turn on the RO faucet to flush for 15 minutes, the water
quality indicator flashes (Blue: good, Purple: fair, Red: poor) based on real-
time inlet water quality.
RO filter: Turn on the RO faucet to flush for 30 minutes, the water
quality indicator flashes (Blue: good, Purple: fair, Red: poor) based on
real-time inlet water quality.
Specifications
Model | E600WA |
---|---|
Product Size (LWH) | 46.21444.3 (cm) /18.25.517.4 (inch) |
Feed Water Temperature | 41-100 °F / 5-38 °C |
Feed Water Pressure | 0.1-0.6 Mpa |
Feed Water Requirement | Municipal Tap Water |
Power Supply | Input:AC 100-240V, 50/60Hz |
Rated Power | 84w |
Water Flow | 21.58L/min |
Applicable Ambient Temperature | 39- 104 °F/ 4-40 °C |
Customer Service
All NexTrend products come with lifetime support, feel free to contact us if you have any questions.
Email: support@nextrendfilter.com
Toll-free: 1-888-666-9168
Mon-Sun: 5: 00 PM-2:00 AM (PST)
WhatsApp/FaceTime ID: +86 158 1749 7067
WecChat ID: B997520270
Website: www.nextrendfilter.com
Read User Manual Online (PDF format)