Product Information
Product Name | YS12V SERIES Switching Power Adapter |
---|---|
Dimensions | 68mm (length) x 30mm (width) x 37mm (height) |
Input Voltage | 100-240VAC |
Input Frequency | 50/60Hz |
Output Voltage | 5V-36V DC |
Rated Power | 12W max |
Features | – Universal AC input/ Full range |
– Energy efficiency level VI
– Extremely low leakage current
– Protection against over load, over voltage, and short circuit
– Withstand voltage of 3KV
– Life Warranty: 3 years
Application| Digital equipment, Electric curtains, Kitchen appliances,
Household appliances
- Input: 100-240VAC 50/60Hz
- Output Voltage: 5V-36V DC
- Rated Power: 12W max
Product Usage Instructions
- Connect the input of the power adapter to a power source with an input voltage range of 100-240VAC and an input frequency of 50/60Hz.
- Connect the output of the power adapter to your device using the appropriate DC plug. Refer to the table below for available DC plug options.
- Ensure that the output voltage matches the voltage requirements of your device. The output voltage range is 5V-36V DC.
- Make sure to observe the rated power of the power adapter, which is 12W max.
- Ensure that the power adapter is protected against over load, over voltage, and short circuit. It has a withstand voltage of 3KV.
- Operate the power adapter within the recommended temperature range of -20°C to +60°C. Refer to the Derating Curve for specific temperature guidelines.
- Store the power adapter in a temperature range of -40°C to +85°C and a humidity range of 10% to 95% RH non-condensing.
- If the power adapter experiences an over load condition (above 110-180% rated output power), it will enter Hiccup mode and automatically recover after the fault condition is removed.
- If the power adapter experiences an over voltage condition (above 120% rated output power), it will shut down the output voltage. To recover, re-power on the adapter.
- If the power adapter experiences a short circuit, it will shut down the output voltage. To recover, re-power on the adapter.
- The power adapter complies with safety regulations TUV and EN62368-1.
- The power adapter has isolation resistance of I/P-O/P, I/P-FG, and O/P-FG at 100M Ohms / 500VDC / 25/70% RH.
- The power adapter complies with EMC emission standards EN55032 (CISPR32), EN61000-3-2, and EN61000-3-3.
- The power adapter complies with EMC immunity standards EN/EN61000-4-2,3,4,5,6,8,11.
- The power adapter has a minimum MTBF (Mean Time Between Failures) of 100,000 hours.
Available DC Plug Options
Type No. | Plug Type | OD (Outer Diameter) | ID (Inner Diameter) | L (Length) |
---|---|---|---|---|
P1I | Tuning Fork Style | 5.5 | 2.1 | 9.5 |
P1L | Barrel Style | 5.5 | 2.5 | 9.5 |
P1M | Lock Style | 5.5 | 2.1 | 11.0 |
P1IR | Center Pin Style | 5.5 | 2.5 | 9.5 |
P1JR | Center Pin Style | 5.5 | 2.1 | 11.0 |
P1LR | Center Pin Style | 5.5 | 2.5 | 9.5 |
P1MR | Center Pin Style | 5.5 | 2.1 | 11.0 |
Note: The DC plug can be changed through customization or by using a quick adapter accessory (sold separately without minimum order quantity).
Features
- Univeral AC input/ Full range
- Energy efficiency level VI
- Leakage Current: <0.25mA
- Extremely low leakage current
- Protection: Over load/Over voltage/Short circuit
- Withstand voltage: 3KV
- Life Warranty: 3 years
Application
- Digital equipment
- Electric curtains
- Kitchen appliances
- Household appliances
Dimensions and Installation
SPECIFICATION
MODEL DETAIL SPEC.| YS12V- 0502000E| YS12V- 0901300E| YS12V- 1201000E|
YS12V- 1500800E| YS12V- 2400500E| YS12V- 3600350E
---|---|---|---|---|---|---
INPUT| Input Voltage range:| 90-264VAC
Input Frequency:| 50/60Hz
Inrush Current:| 50A/230VAC
AC Current:| 0.4A/230VAC
Leakage Current:| <0.25mA/240VAC
Efficiency:| 80%| 84%| 84%| 84%| 84%| 84%
OUTPUT| DC Voltage:| 5V| 9V| 12V| 15V| 24V| 36V
Rated Current:| 2A| 1.3A| 1A| 0.8A| 0.5A| 0.35A
Rated Power:| 10W| 11.7W| 12W| 12W| 12W| 12W
Voltage Tolerance:| ±5.0%| ±5.0%| ±5.0%| ±5.0%| ±5.0%| ±5.0%
Ripple and Noise:| 75mVp-p| 90mVp-p| 120mVp-p| 150mVp-p| 240mVp-p| 300mVp-p
Line Regulation:| ±3%
Load Regulation:| ±5%| ±5%| ±5%| ±5%| ±5%| ±5%
Setup, Rise, Hold Up time:| 1000ms, 30ms/25ms 230VAC at full load
ENVIRONME NTAL| Operating Temperature:| -20 ~ +60 (Refer to “Derating Curve”)
Storage Temp:| -40℃ ~ 85℃
Storage Humidity:| 10 ~ 95% RH
Working Humidity:| 20 ~ 95% RH non-condensing
PROTECTION| Over Load:| Above 110-180% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
Over Voltage:| >120% rated output power
Protection type: Shut down o/p voltage, re-power on to recover
Short Circuit :| Shut down o/p voltage, re-power on to recover
SAFETY & EMC| Safety Regulations:| TUV ,EN62368-1
Withstand Voltage:| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation Resistance:| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70%
RH
EMC Emission:| Compliance to EN55032 (CISPR32), EN61000-3-2,-3
EMC Immunity:| EN/EN61000-4-2,3,4,5,6,8,11
OTHER| MTBF:| 100Khrs min. MIL-HDBK-217F(25℃)
Size:| 683037mm
Weight:| 85g / pcs
Packaging:| 100PCS/CTN
Functional Diagram
DC plug changeable through:
- Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
- Quick adapter accessory (sold separately without MOQ)
Please refer to below table and online selection guide:
Example quick adapter accessory:
Optional DC plug: (Available in customized cable or quick adapter)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>