MW RS-50 Series 50W Single Output Switching Power Supply Owner’s Manual

June 10, 2024
MW

MW RS-50 Series 50W Single Output Switching Power Supply

MW RS-50 Series 50W Single Output Switching Power
Supply

Features

  • Universal AC input/ Full range
  • Protections: Short circuit/ Overload I Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105°C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70°C
  • Withstand 5G vibration test
  • No load power consumption<0.5W
  • High efficiency, long life and high reliability
  • 3 years warranty

SPECIFICATION

MODEL| RS-50-3.3| RS-50-5| RS-50-12| RS-50-15| RS-50-24| RS-50-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 10A| 10A| 4.2A| 3.4A| 2.2A| 1.1A
CURRENT RANGE| 0-10A| 0-10A| 0- 4.2A| 0-3.4A| 0- 2.2A| 0-1.1A
RATED POWER| 33W| 50W| 50.4W| 51W| 52.8W| 52.8W
RIPPLE & NOISE (max.) Note.2| 80mVp-p| 80mVp-p| 120mVp-p| 120mVp-p| 120mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 3V- 3.6V| 4.75- 5.5V| 10.8-13.2V| 13.5-16.5V| 22- 27.2V| 42- 54V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 30ms/230VAC           1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 60ms/230VAC          14ms/115VAC at full load
INPUT| VOLTAGE RANGE| 88- 264VAC        125- 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE| 47- 63Hz
EFFICIENCY(Typ.)| 78%| 83%| 84.5%| 86%| 88%| 89%
AC CURRENT (Typ.)| 1.3A/115VAC           0.8A/230VAC
INRUSH CURRENT (Typ.)| COLD START 33A/230VAC
LEAKAGE CURRENT| <2mA/ 240VAC
PROTECTION| OVERLOAD| 110 – 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.8-4.45V| 5.75- 6.75V| 13.8-16.2V| 17.25- 20.25V| 27.6-32.4V| 55.2 – 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT| WORKING TEMP.| -25 – +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85°C, 10 – 95% RH
TEMP. COEFFICIENT| ±0.03%/°C (0- 50°C)
VIBRATION| 10 – 500Hz, 5G 1Omin./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 6)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1 , EAC TP TC 004, CCC GB4943.1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-0/P, 1/P-FG, 0/P-FG 100M Ohms/ 500VDC / 25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS| MTBF| 2956.7K hrs min.      Telcordia SR-332 (Bellcore); 575.2K hrs min.       MIL-HDBK-217F (25°C)
DIMENSION| 99*97’36mm (L’W’H)
PACKING| 0.41Kg; 45pcs/19.5Kg/0.94CUFT
NOTE|

  1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 0% to 100% rated load.
  6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  7. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
  8. Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Mechanical Specification

Terminal Pin No. Assignment
Pin No . Ass ignment Pin No. Assignment
1 AC/L 4 DC OUTPUT-V
2 AC/N 5 DC OUTPUT +V
3 FG-½  

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Output Derating VS Input Voltage

Output Derating VS Input Voltage

CUSTOMER SUPPORT

Symbols

Downloaded from Arrow.com.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals