zenitel ICX-510 Intelligent Communications Gateway Installation Guide
- June 10, 2024
- Zenitel
Table of Contents
zenitel ICX-510 Intelligent Communications Gateway Installation Guide
About
This document serves as a basic mounting and installation guide for the ICX-510 Intelligent Communication Gateway.
The ICX-510 product package comprises the following components:
Item Numbe | Item Name | Description |
---|---|---|
1002000200 | ICX-510 | Intelligent Communication Gateway |
002500010 | IA-RS1 | Rack Shelf for ICX |
1002500020 | IA-MB1 | Mounting Bracket for ICX-510 |
1002510000 | IPS-AC1 | PSU, Input 85-264 VAC, Output 48 VDC, DIN-Rail |
EMKOB99121 | Snap On Ferrite |
Safety information
This manual describes the necessary steps to install the ICX-510. It contains important instructions that must be followed. ICX-510 must be installed by a trained technician in accordance with national and local regulations.
Zenitel takes no responsibility for damages caused by improper or inadequate mounting.
The ICX-510 is intended for use in restricted access areas for trained service personnel and/or operators, and is not to be installed in locations where children are likely to be present.
Description
Front View
1 | Power LED | Steady green when power is applied to the ICX-510 |
---|---|---|
2 | Status LED | Flashing green when the ICX-510 is running |
3 | Fault LED | Steady amber when the system reports an error. The LED will be |
lit during application or system reset, or if there is a temperature alarm
4| Active LED| Steady blue when the ICX-510 is operational. In a system with
redundant servers, the Active LED will be lit on the operational gateway, and
not lit on the standby gateway
5| Link LED| Steady green when the Ethernet link 0 or 1 is up. There is one
LED for each Ethernet port
6| RX/TX LED| Flashing when receiving or transmitting data on Ethernet port 0
or 1
7| Securing hole| 2 x screw holes, diagonally placed, for M4 screws. Used for
rack mounting
Rear View
1| Status LEDs| | Indicates the same as the LED lights on the front of the
box.
---|---|---|---
2| Ethernet port| Eth0 / Eth1| Two 1 Gbps Ethernet interfaces. Each Ethernet
port is equipped with LED indicators for link and activity
3| Power in| 24-48VDC| ICX-510 is powered by a DC power supply with nominal
voltage 24VDC or 48VDC (Min/Max: 20VDC-63VDC)
4| Console port RS232| RJ45| RS232 port is the RJ45 part of the dual connector
RS232/USB. This is a console port for debugging purposes. Com parameters:
115.200 baud, 8 data bits, no parity, 1 stop bit.
5| USB A port| |
6| USB Micro-B| |
7| Fault Relay| 3 pole terminal bloc| Fault relay is used to indicate system
status together with Fault LED
8| SD card slot| | Used for external storage or system recovery
9| Factory Default Button| Tact switch| Used for resetting ICX-510 to factory
default settings
Wall / shelf mounting
The ICX-510 can be mounted on any flat surface such as a wall or shelf using
the IAMB1 Mounting Bracket. The following example is the procedure for
wall mounting.
The securing holes can also be used to mount the unit to a shelf other than the IA-RS1.
Note that the maximum insertion depth is 6 mm.
Rack mounting
Use the IA-RS1 Rack Shelf when mounting the ICX-510 into a 19” 1HU rack. Two
ICX510 units can be placed side by side on the rack shel
A blanking front can be inserted into the unused position if only one slot is
required.
Installation
Network
Connect the ICX-510 to the IP network. Use an Ethernet cable. Connect the
cable to Ehernet Port 1.
Connect the power supply
Mount the IPS-AC1 power supply on a DIN rail
Ferrite
Before connecting the cable to the ICX-510, the Snap On Ferrite (EMKOB99121)
must be attached near the end of the cable.
Connect the ICX-510
Connect the power cable to the ICX-510. Then connect the power supply to a
100-240VAC power source
Start up
-
Power up the IXC-510. The system uses approx. 20 seconds to start up.
-
Watch the LEDs. During startup the Power LED and the Fault LED will be lit.
-
When up and running, the green status LED will start flashing.
-
Connect a laptop to Ethernet port 0. Use an Ethernet cable
-
Connect to web server – Zenitel Connect Pro User Interface. The ICX-510
comes with an embedded web server which provides functions for system configuration, monitoring and upgrade.
The WEEE Directive does not legislate that Zenitel, as a ‘producer’, shall
collect ‘end of life’ WEEE.
This ‘end of life’ WEEE should be recycled appropriately by the owner who should use proper treatment and recycling measures. It should not be disposed to landfill.
Many electrical items that we throw away can be repaired or recycled. Recycling items helps to save our natural finite resources and also reduces the environmental and health risks associated with sending electrical goods to landfill.
Under the WEEE Regulations, all new electrical goods should now be marked with the crossed-out wheeled bin symbol shown.
Goods are marked with this symbol to show that they were produced after 13th August 2005, and should be disposed of separately from normal household waste so that they can be recycled.
A100K12147 customer.service@zenitel.com
Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Zenitel, Vingtor-Stentofon and Phontech products are developed and marketed by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice. ZENITEL PROPRIETARY. This document and its supplementing elements contain Zenitel or third-party information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend: Zenitel – All rights reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>