About

This document serves as a mounting and installation guide for the Zenitel Multipurpose Kit-1 (ZMK-1). The ZMK-1 provides a whole range of different usage and connection possibilities. This manual mainly deals with the primary function of this kit, namely installation to a touch screen.

For more information and instructions on configuration of the ZMK-1go to: wiki.zenitel.com/wiki/Main_Page.

Item Number Item Name Description
1008560101 ZMK-1 Zenitel Multipurpose Kit – 1

Safety information

This manual describes the necessary steps to install the ZMK-1. It contains important instructions that must be followed. ZMK-1 must be installed by a trained technician in accordance with national and local regulations.

NB! An information symbol indicates that extra consideration must be taken. Damage to equipment can occur. Please read all warnings before installing this product.

Zenitel takes no responsibility for damages caused by improper or  inadequate mounting.

Description

Description

Item Description Comment
1 USB 1 & 2 USB-C (3.0). Used for 3rd party accessories such as camera,

keypad, button module, etc.
2| USB 3| USB-C (2.0). Used for supplying power (1.5A) to display. Also provides touch function if it is a touch-based display.
3| Ethernet port 1 & 2| IEEE 802.3 bt compliant Ethernet ports. Connection to PoE+ or better switch/injector is recommended.
4| Power LED| Steady blue when power is applied to the ZMK-1.
5| HDMI| The HDMI port is to connect to an HDMI display.
6| Speaker Input| Connect an external speaker rated for 8 Ohm
7| Line Input / Output| This is single ended audio lines for sending/receiving audio to/from 3rd party devices such as hearing induction loop.
8| Mic input| Connection to external microphone, either dynamic or electret
9| I/O interface| 2 I/O connection options . Typically used as digitalinput (eg. from a closing contact) or digital output (12mA).
10| Relay| The ZMK-1 has a built-in relay of which a NO contact is available on the connector strip. This can power up to 440W.
11| Power input| Optional 24-48VDC power input from external power supply
12| U-Notch| 2 x U-Notches for mounting.

Mounting

The ZMK-1 can be mounted on any flat surface, either horizontally or vertically.

NB! The ZMK-1 has an IP20 rating, please make sure the unit is mounted in a dry environment.

Product Dimensions

Zenitel recommends installing the ZMK-1 vertically, as shown in the illustration, to ensure optimal airflow through the device.

NB! To ensure adequate ventilation, leave at least 20mm clearance around the ZMK-1 when mounted.

Installation

  1. Connect ZMK-1 to the touch screen by connecting a USB-C cable to the USB port number 3 and an HDMI cable to the HDMI port, then connect the cables to the touch screen.
  2. Connect ZMK-1 to a power source/network. Connect an Ethernet cable to either Eth 1 port or Eth 2 port, then connect a PoE+ Switch/Injector.

NB! The kit must be installed using a shielded Ethernet cable with grounding at the switch end.

Mounting Instructions

Installation

  1. Connect ZMK-1 to the touch screen by connecting a USB-C cable to the USB port number 3 and an HDMI cable to the HDMI port, then connect the cables to the touch screen.
    Installation Cable

  2. Connect ZMK-1 to a power source/network. Connect an Ethernet cable to either Eth 1 port or Eth 2 port, then connect a PoE+ Switch/Injector.

NB! The kit must be installed using a shielded Ethernet cable with grounding at the switch end.
Instructions

Connectors

The ZMK-1 provides a whole range of different usage and connection possibilities. The set of connectors enables tailor-made solutions suited to most needs. Connect the various components as shown in this figure.
Connectors Instructions

Start up

  1. Power up the ZMK-1 when all selected components are connected. The system uses approximately 10 seconds to start up.

  2. Watch the LED. When up and running, the blue Power LED will be lit.

  3. Connect a laptop to the switch. Use an Ethernet cable

  4. Get the IP address. When the ZMK-1 is connected to the network, the IP address of the device is automatically assigned in one of two ways:
    Wiring Instructions

  5. In IP address is automatically obtained from a DHCP server if a DHCP server is present on the network.

  6. If there is no DHCP server, a random IP address in the range 169.254.x.x will be assigned.

  7. Connect to web interface. The ZMK-1 feature an embedded web interface, which allows users to log in using a standard web browser Open a web browser (e.g. Firefox or Chrome), and log to the interface using the units IP address.

  The ZMK-1 kit can operate in two different modes, Edge and SIP, depending on what kind of server it is registered to. Enter the link or scan the QR-code below to go to Zenitel Wiki for configuration instructions.

Zenitel Wiki: wiki.zenitel.com/wiki/Main_Page.

Contact Information

Visit zenitel.com to find your country’s contact information.

Specifications

Technical specifications Value
Weight 320g
Dimensions (HxWxD) 36.5 x 154 x 71.5mm
IP Rating IP20
IK Rating IK08
Relative humidity < 95% not condensing
Operating temperature range -40° to 70° C / -40° to158 ° F
Encapsulation material Aluminum
Power Options PoE, Poe+, 24-48VDC PSU
PoE (power over Ethernet) IEEE 802.3af standard, IEEE 802.3at

The WEEE Directive does not legislate that Zenitel, as a ‘producer’, shall collect ‘end of life’ WEEE.

This ‘end of life’ WEEE should be recycled appropriately by the owner who should use proper treatment and recycling measures. It should not be disposed to landfill.

Many electrical items that we throw away can be repaired or recycled. Recycling items helps to save our natural finite resources and also reduces the environmental and health risks associated with sending electrical goods to landfill.

Under the WEEE Regulations, all new electrical goods should now be marked with the crossedout wheeled bin symbol shown.

Goods are marked with this symbol to show that they were produced after 13th August 2005, and should be disposed of separately from normal household waste so that they can be recycled.


DOC. NO.

A100K12170v1.4 customer.service@zenitel.com

Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Zenitel, Vingtor- Stentodfon and Phontech products are developed and marketed by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice. ZENITEL PROPRIETARY. This document and its supplementing elements contain Zenitel or third-party information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend: Zenitel – All rights reserved.

zenitel Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals