zenitel TEIV-1+ Turbine Extended IP Video Station
Product Information
- The TEIV+ Turbine Extended IP Video Station is a video intercom system that allows for extended communication and security features. It consists of various components including the TEIV-1+ and TEIV-4+ models, as well as additional accessories such as the TA-33 and TA-34 backboxes.
- The TEIV-1+ model features a camera, speaker, LCD display, standard keypad, navigation keys, confirmation/call key, cancel key, and microphone.
- The TEIV-4+ model includes a camera, speaker, call key, card reader, and microphone. Both models offer advanced functionalities for video intercom and security purposes.
- The product also includes a CPU module, card reader slot (for TEIV-4+ model), card reader bracket, relay, I/O interface, line output, speaker input, microphone input, power input, LAN port, SD-card slot, and USB-C port.
- The TEIV+ series is designed to be installed by a competent person in accordance with national and local regulations. Following the provided instructions is crucial to ensure proper installation and avoid any equipment damage or property loss.
Product Usage Instructions
Powering the Station:
The TEIV+ station can be powered using Power over Ethernet (PoE) or a 24VDC power supply.
- If using PoE, connect an Ethernet cable from the LAN port of the station to a PoE switch. Ensure the Ethernet cable is shielded with grounding at the switch end. Attach the included Snap On Ferrite near the LAN port inside the backbox.
- If PoE is not available, connect a 24VDC power supply to the Power Input of the station.
Mounting Considerations
- Ensure there is sufficient clearance under the station to prevent smothering of the microphone aperture.
- To achieve an optimal field of view, mount the station so that the lens is placed at a height of approximately 120 cm.
About
- This document serves as a mounting and installation guide for the TEIV+ Turbine Extended IP Video Stations.
- For more information and instructions on configuration of the
- TEIV-1+ and TEIV-4+ go to: wiki.zenitel.com/wiki/Main_Page. The TEIV+ series consists of the following components:
Item Number | Item Name | Description |
---|
1008317110
|
TEIV-1+
| Turbine Extended IP Video Intercom with Keypad and Display
1008318240| TEIV-4+| Turbine Extended IP Video with RFID Card Reader Space
1008140330| TA-33| Turbine Extended On-wall Backbox
1008140340| TA-34| Turbine Extended Flushmount Backbox
Safety information
This manual contains important instructions that must be followed. These instructions are intended to ensure that the product is mounted and installed correctly to avoid equipment damage or property loss. A note symbol indicates that extra care must be taken. Damage to equipment can occur, or it may not function as intended. Please read all warnings before installing this product. The station should be installed by a competent person in accordance with national and local regulations. Zenitel takes no responsibility for damages caused by improper or inadequate installation.
Description ****
TEIV-4+
Item | Description |
---|---|
1 | Camera |
2 | Speaker |
3 | Call Key |
4 | Card Reader |
5 | Microphone |
Item | Description | Comment |
---|---|---|
1 | CPU Module | |
2 | Card Reader Slot | Only in use for TEIV-4+ |
3 | Card Reader Bracket |
4
|
Relay
| Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W.
5
|
I/O interface
| 6 general purpose I/Os.. Each I/O can be configured as either input, output,
or LED driver.
6| Line Output| A balanced 600 ohm audio line out with induction loop signal.
7| Speaker Input| Connect an external speaker rated for 8 Ohm
8| Microphone input| Electret mic input
9| Power Input| Optional 24VDC power input from external power supply
10| LAN Port| 10/100/1000Mbps RJ-45 port connecting to Ethernet. PoE/PoE+ is
supported.
11| SD-card Slot|
12| USB-C Port| Used during production process and for recovery
Installation
- TEIV-1+/TEIV-4+ can be powered by PoE. This is done by connecting an Ethernet cable to the LAN port of the station and a PoE switch.
- NB! If PoE is used, the station must be installed using a shielded Ethernet cable with grounding at the switch end.
- The included Snap On Ferrite (EMKOB99123.0100) must be attached to the Ethernet cable near the LAN port inside the backbox.
- If the switch does not support PoE, a 24VDC power supply can be connected to the stations Power Input.
Mounting
Mounting considerations
- Ensure there is enough clearance under the station so that the microphone aperture is NOT smothered.
- To achieve an optimal field of view, the station should be mounted so that the lens is placed at a height of approx. 120 cm.
Mounting card readers
The TEIV-4+ has a card reader slot, fitting either HID Signo 20 ReaderTerminal
Strip or TWN4 Palon Compact LEGIC PCB. Do the following when mounting the card
readers.
HID Signo 20 ReaderTerminal Strip
- Unscrew the Card Reader Bracket. Make sure the Self-Clinching Standoffs are facing outwards.
- Remove the back lid from the card reader, and fasten the lid to the Card Reader Bracket. Then reattach the card reader to the lid.
- Fasten the Card Reader bracket to the TEIV-4+. Make sure to use the U-notches on the bracket when fastening.
- Connect the card reader to the local door controller as part of the access system.
TWN4 Palon Compact LEGIC PCB
- Unscrew the Card Reader Bracket. Make sure the Self-Clinching Standoffs are facing inwards. Separate the two parts of the card reader and attach the part with screw holes to the Card Reader
- Bracket. Then reassemble the card reader.
- Fasten the Card Reader bracket to the TEIV-4+. Make sure to use the U-notches on the bracket when fastening.
- Connect the card reader to the local door controller as part of the access system.
Flush mounting
For flush mounting the Turbine Extended, use the TA-34 Turbine Extended Flushmount Backbox.
- Insert the TA-34 Backbox into designated slot in the wall.
- Fasten the back box to the wall.
- Plug the Ethernet cable into LAN port on the station. If the switch does not support PoE, a 24VDC Power Supply can be connected to the stations Power Input.
- Mount the Turbine Extended Station onto the Backbox with the M5 fasteners provided. Apply 1.5 Nm torque.
On-wall mounting
For mounting the Turbine Extenden on the wall, use the TA-33 Turbine Extended Onwall Backbox.
- Mounting holes are to be drilled as shown in the figure.
- Max. recommended screw diameter: ISO M6 or ANSI 1/4”.
- Screw length must be greater than 25 mm or 1”.
- A4 stainless steel socket head screws/bolts are recommended. Max. screw head diameter: 9.5 mm or 3/8”.
- Mount the TA-33 Backbox onto the wall using A4 socket head screws
- Plug the Ethernet cable into LAN port on the station. If the switch does not support PoE, a 24VDC Power Supply can be connected to the stations Power Input.
- Mount the Turbine station onto the back box with the M5 fasteners provided. Apply 5 Nm torque.
- To ensure the IP-66 rating, use the grommets and M20 cable gland provided for the cable holes on the back box.
Get started
- When the Turbine Extended Station is connected to the network, its IP address is automatically obtained from a DHCP server or an IP adress in the range 169.254.xx will be assigned.
- To make the station speak its IP address, press the Call Key on the station.
- The Turbine Extended can operate in two different modes,
- Edge and SIP, depending on what kind of server it is registered to. Enter the link or scan the QR-code below to go to Zenitel Wiki for configuration instructions.
- Zenitel Wiki: wiki.zenitel.com/wiki/Main_Page.
Contact Information
Visit zenitel.com. to find your country’s contact information.
Specifications
Technical specifications | Value |
---|---|
Weight | TEIV-1+: 1.08kg TEIV-4+: 1.05kg |
Dimensions (HxWxD) | 305 x 120 x 72,5mm |
IP Rating | IP 66 |
IK Rating | IK08 |
Relative humidity | < 95% not condensing |
Operating temperature range | -40° to 70° C / -40° to 158 ° F |
Encapsulation material | Aluminium |
Power Options | PoE, PoE+, 24VDC PSU |
PoE (power over Ethernet) | IEEE 802.3af standard, IEEE 802.3at |
Power consumption | Idle 3.5W, max 12W (depending on volume) |
- The WEEE Directive does not legislate that Zenitel, as a ‘producer’, shall collect ‘end of life’ WEEE.
- This ‘end of life’ WEEE should be recycled appropriately by the owner who should use proper treatment and recycling measures. It should not be disposed to landfill.
- Many electrical items that we throw away can be repaired or recycled. Recycling items helps to save our natural finite resources and also reduces the environmental and health risks associated with sending electrical goods to landfill.
- Under the WEEE Regulations, all new electrical goods should now be marked with the crossed-out wheeled bin symbol shown.
- Goods are marked with this symbol to show that they were produced after 13th August 2005, and should be disposed ofseparately from normal household waste so that they can be recycled.
Hear, be heard, and be understood – every time and everywhere Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Zenitel, Vingtor-Stentofon and Phontech products are developed and marketed by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice. ZENITEL PROPRIETARY. This document and its supplementing elements contain Zenitel or third-party information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend: Zenitel – All rights reserved. sales@zenitel.com. DOC. NO. A100K12201v1.5