zenitel A100K11254 TCIS Turbine Compact IP Mounting User Manual

June 3, 2024
Zenitel

zenitel-LOGO

zenitel A100K11254 TCIS Turbine Compact IP Mounting

zenitel-A100K11254-TCIS-Turbine-Compact-IP-Mounting-
PRODUCT

Turbine Compact IP Stations

This document describes the dimensions, mounting procedure, and connections of the Turbine Compact IP Stations. Zenitel takes no responsibility for damages caused by improper or inadequate mounting. The Turbine Compact IP product range comprises the following stations & accessories:

Item Number Type Item Name
1008111010 TCIS-1 Turbine Compact IP – thermoplastic front plate
1008111020 TCIS-2 Turbine Compact IP – stainless steel front plate
1008111030 TCIS-3 Turbine Compact IP – thermoplastic front plate
1008111040 TCIS-4 Turbine Compact IP – thermoplastic front plate with PMOLED

display
1008111050/1008111901| TCIS-5/TCIS-C1| Turbine Compact IP – thermoplastic front plate with PMOLED display
1008111060| TCIS-6| Turbine Compact IP – thermoplastic front plate with PMOLED display
1008113020| TCIA-2| Turbine Compact Analog over IP Intercom
1008140010| TA-1| Turbine On-Wall Back Box
1008140020| TA-2| Turbine Flush Mount 2-Gang Double-Depth Back Box
1008140050| TA-5| Turbine Bracket for Flush Mount Back Box

zenitel-A100K11254-TCIS-Turbine-Compact-IP-Mounting-
FIG-1

TCIS Compact Station Dimensionszenitel-A100K11254-TCIS-Turbine-Compact-
IP-Mounting-FIG-2

On-Wall Surface Mounting

On-Wall Surface Mount Back Box – TA-1

Mounting holes are to be drilled as shown. Max. recommended screw diameter: ISO M6 or ANSI 1/4″. Screw length must be greater than 25 mm or 1″. A4 stainless steel socket head screws/bolts are recommended. Max. recommended screw head diameter: 9.5 mm or 3/8″.zenitel-A100K11254-TCIS-Turbine-Compact-
IP-Mounting-FIG-3

Included:

  • 4x M5 Fasterners
  • 2x Grommets
  • 1x M20 Cable Gland
  • 4x Washers for extra protection against corrosive effects between surfaces to be placed at bottom of the 4 mounting holes.

On-Wall Surface Mounting Procedure

  • The Gasket MUST be mounted to seal the station!
  • Ensure the station is mounted vertically with the microphone aperture facing down.
  •  Ensure there is enough clearance under the station so that the microphone aperture is NOT smothered.
  • Place the washers at the bottom of the 4 mounting holes on the back box.
  • Use the grommets and M20 cable gland provided for the cable holes on the back box.
  1. Mount the back box onto the wall using A4 socket head screws
  2. Fit the gasket onto the back box with the ridged side facing down ­ Plug the Ethernet cable into the RJ-45 port on the station
  3. Mount the Turbine station onto the back box with the M5 fasteners provided applying 1.5 Nm torque

3 Flush Mounting

Flush Mount 2-Gang Double-Depth Back Box – TA-2zenitel-A100K11254-TCIS-
Turbine-Compact-IP-Mounting-FIG-5

It is recommended to utilize back boxes with weep holes at the bottom.

Flush Mount Bracket – TA-5

The TA-5 Bracket or other customized solution is required for flush mounting .zenitel-A100K11254-TCIS-Turbine-Compact-IP-Mounting-
FIG-6

Flush Mounting Procedure

The Gasket MUST be mounted to seal the station

  • Ensure the station is mounted vertically with the microphone aperture facing down.
  • Ensure there is enough clearance under the station so that the microphone aperture is NOT smothered.
  • Apply silicone sealant all around the aluminum frame of the station, making sure to leave the microphone aperture open.
  1. Mount the 2-gang back box into the wall Mount the bracket onto the back box with #6-32
  2. UNC pan head screws Fit the gasket onto the bracket with the ridged side facing down
  3. Plug the Ethernet cable into the RJ-45 port on the station
  4. Mount the Turbine station onto the bracket with the M5 fasteners provided

Connections

Ethernet / Power| 10/100 Mbps Ethernet RJ-45 port for LAN

(uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.

---|---
Secondary Power| 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
Relays| There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W.
Input/Output| 6 I/Os are available. Each I/O can be configured as either input, output, or LED driver.
Audio Line Out| A balanced 600 ohm audio line out with induction loop signal

The TCIA-2 has different connections

Use cables crimped with ferrules for terminal block connectors

  • When the Turbine Station is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range
    169.254.x.x will be assigned.

  • To make the station speak its IP address, press the call button on the station.

www.zenitel.com customer.service@zenitel.com

Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Zenitel and Vingtor-Stentofon products are developed and marketed by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice. ZENITEL PROPRIETARY. This document and its supplementing elements, contain Zenitel or third party information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend: Zenitel ­ All rights reserved.