Product Information

The ICX-510-IA is an Intelligent Communication Gateway designed for use in restricted access areas by trained service personnel and/or operators. It is not intended to be installed in locations where children are likely to be present. The product package includes the following components:

Item Number Item Name Description
1002000110 ICX-510-IA Intelligent Communication Gateway incl ICXAlphaCom

Core
1002500010| IA-RS1| Rack Shelf for ICX-500 Mounting
1002500020| IA-MB1| Mounting Bracket for ICX-500
1002510000| IPS-AC1| PSU, Input 85-264 VAC, Output 48 VDC, DIN-Rail

Safety Information

The ICX-510-IA must be installed by a trained technician in accordance with national and local regulations. Improper or inadequate mounting may cause damages. Zenitel takes no responsibility for such damages. The product is intended for use by trained personnel and/or operators in restricted access areas.

Front View Description

  1. Power LED: Steady green when power is applied to the ICX-510-IA.
  2. Status LED: Flashing green when the ICX-510-IA is running.
  3. Fault LED: Steady amber when the system reports an error. The LED will be lit during application or system reset, or if there is a temperature alarm.
  4. Active LED: Steady blue when the ICX-510-IA is operational. In a system with redundant servers, the Active LED will be lit on the operational gateway, and not lit on the standby gateway.
  5. Link LED: Steady green when the Ethernet link 0 or 1 is up. There is one LED for each Ethernet port.
  6. RX/TX LED: Flashing when receiving or transmitting data on Ethernet port 0 or 1.
  7. Securing hole: Two screw holes, diagonally placed, for M4 screws. Used for rack mounting.

Rear View Description

  1. Status LEDs: Indicates the same as the LED lights on the front of the box.
  2. Ethernet port (Eth0 / Eth1): Two 1 Gbps Ethernet interfaces. Each Ethernet port is equipped with LED indicators for link and activity.
  3. Power in: ICX-510-IA is powered by a DC power supply with a nominal voltage of 24VDC or 48VDC (Min/Max: 20VDC-63VDC).
  4. Console port RS232: RJ45 part of the dual connector RS232/USB. This is a console port for debugging purposes. Com parameters: 115.200 baud, 8 data bits, no parity, 1 stop bit.
  5. USB A port
  6. USB Micro-B
  7. Fault Relay: Used to indicate system status together with Fault LED.
  8. SD card slot: Used for external storage or system recovery.
  9. Factory Default Button Tact switch: Used for resetting ICX-510-IA to factory default settings.

Product Usage Instructions

Wall / Shelf Mounting

  1. If mounting on a wood or steel surface, skip this step. Otherwise, drill two holes using a 5 mm drill bit. The hole dimensions should be 120×90 mm (HxW).
  2. Insert three Nylon Plugs (5 mm) into the drilled holes (not included).
  3. Attach four Mounting clips to the ICX-510-IA.
  4. Securely mount the ICX-510-IA on the wall or shelf using the mounting clips.

Rack Mounting
When mounting the ICX-510-IA into a 19″ 1HU rack, use the IA-RS1 Rack Shelf. Two ICX-510-IA units can be placed side by side on the rack shelf.

About
This document serves as a basic mounting and installation guide for the ICX-510-IA Intelligent Communication Gateway.
The ICX-510-IA product package comprises the following components:

Safety information

  • This manual describes the necessary steps to install the ICX-510-IA. It contains important instructions that must be followed. ICX-510-IA must be installed by a trained technician in accordance with national and local regulations.
  • Zenitel takes no responsibility for damages caused by improper or inadequate mounting.
  • The ICX-510-IA is intended for use in restricted access areas for trained service personnel and/or operators, and is not to be installed in locations where children are likely to be present.

Description

Front View

Rear View

Wall / shelf mounting

The ICX-510-IA can be mounted on any flat surface such as a wall or shelf using the IA-MB1 Mounting Bracket. The following example is the procedure for wall mounting.

Rack mounting

Installation

  1. Network
    Connect the ICX-510-IA to the IP network. Use an Ethernet cable. Connect the cable to Ehernet Port 1.

  2. Power supply
    Mount the IPS-AC1 power supply on a DIN rail and terminate the power cables.

  3. Ferrite
    Before connecting the cable to the ICX-510-IA, the included Snap On Ferrite (EMKOB99121) must be attached near the end of the cable.

  4. Connect the ICX-510-IA
    Connect the power cable to the ICX-510-IA. Then connect the power supply to a 100-240VAC power source.

Start up

  1. Power up the IXC-510-IA.

  2. Watch the LEDs. During startup the Power LED and the Fault LED will be lit. When up and running, the green status LED will start flashing.

  3. Connect a laptop to Ethernet port 0. Use an Ethernet cable.

  4. Connect to a web server – ICX Web. The ICX-510-IA comes with an embedded web server that provides functions for system configuration, monitoring and upgrade.
    Open a web browser (e.g.Firefox or Chrome), and log on to the web server using IP address 169.254.1.5.

  5. Enter the link or scan the QR code below to go to Zenitel Wiki for configuration instructions.
    Zenitel Wiki: wiki.zenitel.com/wiki/Main_Page.

Contact Information

Visit zenitel.com to find your country’s contact information.

Specifications

Zentel hereby declares that this product is in compliance with the essential requirements and other relevant provisions of directive 2014/53/EU and all other applicable EU directive requirements. The complete declaration can be found at www.zenitel.com
The WEEE Directive does not legislate that Zenitel, as a ‘producer’, shall collect ‘end of life’ WEEE.

This ‘end of life’ WEEE should be recycled appropriately by the owner who should use proper treatment and recycling measures. It should not be disposed to a landfill. Many electrical items that we throw away can be repaired or recycled. Recycling items helps to save our natural finite resources and also reduces the environmental and health risks associated with sending electrical goods to landfills. Under the WEEE Regulations, all new electrical goods should now be marked with the crossed-out wheeled bin symbol shown. Goods are marked with this symbol to show that they were produced after 13th August 2005, and should be disposed of separately from normal household waste so that they can be recycled.

Hear, be heard, and be understood
every time and everywhere
A100K12241
customer.service@zenitel.com
Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Zenitel, Vingtor-Stentofon and Phontech products are developed and marketed by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice. ZENITEL PROPRIETARY. This document and its supplementing elements contain Zenitel or third-party information that is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend: Zenitel – All rights reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals