HOLOPHANE PTE2 Taft LED Post-top Lanterns Instruction Manual

June 9, 2024
HOLOPHANE

HOLOPHANE logo HOLOPHANE PTE2 Taft LED Post-top Lanterns - logo
1PTE2 Taft LED Post-top Lanterns
Instruction Manual

PTE2 Taft LED Post-top Lanterns

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

LED IMPORTANT SAFETY INSTRUCTIONS

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly  become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING
RISK OF ELECTRIC SHOCK
 Disconnect or turn off power before installation or servicing.
 Verify that supply voltage is correct by comparing it with the luminaire label information.
 Make all electrical and grounded connections in accordance with the NationalElectrical Code (NEC) and any applicable local code requirements.
 All wiring connections should be capped with UL approved recognized wire connectors.
CAUTION
RISK OF INJURY
Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
Avoid direct eye exposure to the light sourcewhile it is on.
WARNING
RISK OF BURN
Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
Do not exceed maximum wattage marked on luminaire label.
** Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF FIRE
**
Keep combustible and other materials that can burn, away from lamp/lens.
** Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
**
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED  fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
Only use fixture in its intended location.
LED products are Polarity Sensitive. Ensure proper Polarity before installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties.
For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands| Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC| Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting| Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen| Controls
DARK TO LIGHT
Lighting Control & Design
ROAM
Sensor Switch
Synergy
DISCONTINUED
---|---|---|---|---

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2011 Acuity Brands Lighting, Inc. All rights reserved. 3/15/11

Installation and Maintenance Manual

HOLOPHANE PTE2 Taft LED Post-top Lanterns - fig 7GR1777, GR1780, GR1830

INTRODUCTION

1.1 Product Description.
This post top luminaire is designed with LED’s which do not require replacement.
The luminaire includes a plug-in electrical module that contains the photocontrol receptacle when specified. These modules are common to all luminaire styles in this  series.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1.2 Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
866-759-1577

INSTALLATION

2.1 Tools and Material Required.
Table 1. Installation Tools and Materials

DESCRIPTION USE
Flat-end Screwdriver Installation of electrical wiring
1/4” Nut driver Electrical tray and reflector screws
3/8” Nut driver LED cover (If applicable)
3/16″ Allen Wrench Set screws (Mounting)
Torque Wrench Set screws

2.2 Luminaire Installation.

2.2.1 This product has an LED array already installed and is ready to operate by placing on mounting pole or tenon and making final wire connection by removing the wiring cover. See Figure 3.
Figure 1 is provided to show internal parts so you can become familiar with the product.
2.2.2 Place and level the luminaire on the pole.
2.2.3 Orient wire way entry in housing to face the street.
2.2.4 Alternately tighten the set screws to assist in centering and leveling the luminaire. Tighten the (6) set screws to 10-12 foot – pounds. HOLOPHANE
PTE2 Taft LED Post-top Lanterns - fig 6

2.2.5 Remove cover nuts and LED cover.
2.2.6 Orient “street side” on optic between street side ribs on housing.
See Figure 2.
2.2.7 Orient “street side” and raised rib on heat sink with rib shown, using wire way as reference. See Figure 2. Letter “B” on heat sink will face “street side” on optic and wire way on housing.HOLOPHANE PTE2 Taft LED Post-top
Lanterns - fig 5
2.2.8 Wire incoming leads accordingly. Connect incoming ground wire to ground wire(s) attached to inside of wiring chamber. Carefulplace connections in wiring chamber and replace cover, cover gaskeand tighten cover screws to 16-18 in-lbs. See Figure 3.
HOLOPHANE PTE2 Taft LED Post-top Lanterns - fig 4 2.2.9 For units equipped with 0-10V dimming, you must remove the LED cover and electrical tray (See Figure 1 and Figure 4) to locate the gray and violet leads coming from the driver. If the unit is to be connected to dimming control gear (not included), trim, strip, and connect these leads per the dimming control gear manufacturer’s instructions. The violet lead is positive, and the gray lead is negative.
If the unit is not to be connected to dimming control gear, leave the leads individually capped.
CAUTION
LEADS USED FOR DIMMING CONTROLS ARE TO BE SEPARATED FROM MAIN POWER CONDUCTORS IN A MANNER TO SATISFY STATE AND LOCAL CODES.
2.2.10 Units supplied with a photo control option require a shorting plug or a twist lock photo control to be installed. Install the device by twisting it clockwise.
CAUTION
A PHOTO CONTROL THAT MEETS THE REQUIREMENTS OF ANSI C136.10 AND WITH A CLEAR WINDOW ON THE SIDE THAT EXPOSES THE PHOTOCELL MUST BE USED.
2.2.11 Re-install LED cover and cover nuts.
2.2.12 Energize the unit and check for proper operation

MAINTENANCE

3.1 Cleaning
3.1.1 Make sure the unit is de-energized.
3.1.2 Wipe off exterior dirt and debris using a soft, clean cloth.
CAUTION
DO NOT USE ABRASIVE CLEANSERS ON OPTICAL SURFACES. THEIR USE MAY RESULT IN THE LOSS OF OPTICAL EFFICIENCY.
3.2 Electrical Component Replacement
3.2.1 To replace photocontrol. (If provided) Make sure the unit is de- energized. Twist counterclockwise and remove. Replace with equivalent photocontrol.
3.2.2 For all other electrical parts- Make sure the unit is deenergized. Open the housing by unscrewing and removing cover nuts (4) (Figure 1). Remove main power quick disconnect and photo control disconnect (if applicable).  Remove LED cover and heat sink and support on a clean horizontal work surface. Be cautious not to damage the LED array in the process.
Remove reflector and loosen two keyway screws, turn and remove electrical tray; gently lay  on its  side to allow driver bracket to rest between arms of housing. (Figure. 4 shows electrical tray removed for clarity)
3.2.3 To replace LED driver. Make sure the unit is de-energized. Loosen and remove electrical tray to access parts. Disconnect input and output via quick disconnects and remove (2) mounting screws. Replace with Holophane approved driver. See Figure 4. If no other components are to be replaced go to Section 3.2.6.
HOLOPHANE PTE2 Taft LED Post-top Lanterns - fig 2

3.2.4 Replacement of surge protector. Disconnect quick disconnectplug coming from terminal and quick disconnect going to optical compartment. Remove SPD SCREW connecting the surge protector to the plate; retain screws for re- installation.
3.2.5 For standard surge units, remove the screw from mounting bracket and slide surge protector through opening in mounting bracket. Replace with Holophane approved device. See Figure 4.
3.2.6 Bundle and secure the wiring in a manner like the way it was originally secured to avoid pinching of wires when re-installing the module into the housing.
3.2.7 Replace electrical tray on keyway slots, twist clock-wise and tighten screws.
3.2.8 Reverse the order to connect wiring harness(s), LED cover, latch and latch screw.
HARNESS NOTES
Any slack in the harnesses should neatly be pushed through the center opening in the lower reflector as the cover is closed.
3.2.9 Energize the unit and check for proper operation.

Optional Equipment Installation

4.1 Scroll – Attach scroll to ballast housing below wire way cover, replace upper set screws with 3/8 set screws in kit. See Figure 5.
4.2 Filigree – Remove two retaining nuts from top cover and place Filigree over the studs. Reinstall the two retaining nuts. See Figure 5.
HOLOPHANE PTE2 Taft LED Post-top Lanterns - fig 3

LIMITED WARRANTY AND LIMITATION OF LIABILITY

The Holophane limited warranty and limitation of liability is published in the “Terms and Conditions” section of the current Holophane buyer’s guide and is available from your local Holophane sales representative.

Field Adjustable Output Module

HOLOPHANE PTE2 Taft LED Post-top Lanterns - fig 1

P10 – AS, MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 76%
3| 63%| 64%
2| 52%| 54%
1| 39%| 42%
P20 – AS, MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 76%
3| 63%| 64%
2| 52%| 54%
1| 39%| 42%

Field Adjustable Output Module
The Field Adjustable Output (AO) module is an onboard device that adjusts the light output and input wattage to meet site specific requirements, allowing a single fixture configuration to be flexibly applied in many different applications. The AO option is available on the PTE2 series. The following data tables are for the AS, MVOLT, AH, HVOLT voltage options. voltage options.

P30 – AS, MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 74%
3| 64%| 62%
2| 52%| 51%
1| 40%| 39%
P40 – AS, MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 74%
3| 64%| 62%
2| 52%| 51%
1| 40%| 39%
P50 –  AS, MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 89%| 87%
4| 78%| 74%
3| 66%| 61%
2| 54%| 50%
1| 41%| 38%
P10 – AH, HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 75%
3| 63%| 64%
2| 52%| 53%
1| 39%| 41%
P20 – AH, HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 75%
3| 63%| 64%
2| 52%| 53%
1| 39%| 41%
P30 –  AH, HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 75%
3| 64%| 63%
2| 52%| 51%
1| 40%| 40%
P40 – AH, HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 75%
3| 64%| 63%
2| 52%| 51%
1| 40%| 40%
P50 – AH, HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 89%| 88%
4| 78%| 75%
3| 66%| 63%
2| 54%| 51%
1| 41%| 39%

HOLOPHANE logoAcuity Brands Lighting, Inc.
3825 Columbus Rd SW, Granville, OH 43023
IM-434-B, 4/23/2020
©2020 Acuity Brands Lighting Inc., All Rights Reserved
Visit our web site at
www.holophane.com
Printed in USA

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HOLOPHANE User Manuals

Related Manuals