Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.

Function / Application

Laser distance meter with camera function
Perpendicular areas, circular areas, circular volumes, triangular areas and trapezoidal areas can be determined using this multi-functional laser rangefinder. It can also determine indirect heights and take point-to-point measurements. An HD camera also acts as a spotter during measurement. The measurement data can be transferred to mobile devices via the Bluetooth interface using the free MeasureNote app.

General Safety Instructions

  • The device must only be used in accordance with its intendedpurpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.
  • Clean and dry the device before use.
  • When using the device outdoors, make sure that the weather conditions are appropriate and/or that suitable protection measures are taken.
  • Note local and national safety instructions to ensure proper use of the device.

Safety instructions

Using class 2 lasers

Laser radiation!
Do not stare into the beam!
Class 2 laser < 1 mW · 635 nm EN 60825-1:2014/AC:2017

  • Attention: Do not look into the direct or reflected beam.
  • Do not point the laser beam towards persons.
  • If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
  • Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Dealing with RF radiation

  • The measuring device is equipped with a wireless interface.
  • The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
  • Umarex GmbH & Co. KG hereby declares that the DistanceMaster LiveCam radio equipment complies with the essential requirements and other provisions of the European Radio Equipment Directive 2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following address: https://packd.li/ll/akk/in

Product Overview

  1. Laser reception field
  2. Display
  3. Battery compartment (backside)
  4. Connection socket for USB charger
  5. Camera
  6. Laser outle
    Product Overview

KEYPAD:

  • a Function menu / Timer function
  • b Laser on / measure / min/max continuous measurement
  • c Subtraction function / back / View saved measured values and screenshots
  • d Camera function / Screenshot
  • e ON / OFF / back
  • f Addition function / before
  • g Settings menu
    Product Overview

DISPLAY:

  • h Battery symbol
  • i Digital bubble level
  • j Set measuring function
  • k Measurement point (reference) front / thread / rear
  • l Intermediate values / min/max values
  • m Measurement values / Measurement results
    Product Overview

Inserting rechargeable batteries

Open the battery compartment and insert the rechargeable batteries (3x NiMH, type AAA) as indicated by the installation symbols. Be sure to pay attention to polarity. The rechargeable batteries can be charged in the device with the supplied USB charging cable.
Inserting rechargeable batteries

Switch on, measure and switch off:
Switch on, measure and switch off:

Settings menu:
Settings menu:

Select setting option

Change value

Symbols Save setting (optional)

Exit menu / Delete the last measured value

Addition and subtraction of lengths:
Addition and subtraction of lengths:

Further lengths are added by pressing the DIST button.

min/max continuous measurement:
min/max continuous measurement:
The LC display shows the max value, the min value, the differential value and the current value.

Area measurement:
Area measurement:
The room perimeter is additionally shown on the LC display.

Area calculation:
Area calculation:

Volume measurement:
Volume measurement:

Volume calculation:
Volume calculation

Point-to-point measurement:
Point-to-point measurement

Angle function:
Angle function:
The measurement results are determined automatically by the 360° inclination sensor.

The back of the device can be used as a reference surface ! for measuring angles.

Automatic height:
Automatic height:

Pythagoras function 1:
Pythagoras function 1:

Pythagoras function 2:
Pythagoras function 2:

Pythagoras function 3:
Pythagoras function 3:

Trapezoidal function 1:
Trapezoidal function 1:

Trapezoidal function 2:
Trapezoidal function

Triangular area measurement:
Triangular area measurement

Circular area measurement:
Circular area measurement
Circumference is additionally shown on the LC display.

Circular volumes:
Circular volumes
Circular area is additionally shown on the LC display.

Stake out function:
Stake out function

Select value

Change value

Symbols Save setting (optional)

Exit menu

To reach the target move the device in the direction of the arrow

Timer function:
Timer function:

Camera function:

The HD camera has an automatic 4x zoom.
Camera function: 

Memory function:

The device has 50 storage locations.
Memory function: 

Reference point displacement:

The set tolerance is calculated directly from the result of the measurement.

Select value

Change value

Symbols Save setting (optional)

Exit menu

Data transfer

This device has digital connectivity which allows wireless data transfer to mobile devices such as smart phones or tablets with a wireless interface. The system prerequisites for a digital connection are specified at https://packd.li/ble/v2

This device can generate a wireless connection to devices which are compatible with the wireless standard IEEE 802.15.4. The wireless standard IEEE 802.15.4 is a transfer protocol for Wireless Personal Area Networks (WPAN). The range is set to a maximum distance of 10 m from the terminal device and greatly depends on the ambient conditions such as the thickness and composition of walls, sources of interference as well as the transmit / receive properties of the terminal device.

Enable / disable Digital Connection

Enable / disable

Symbols Save setting (optional)

Exit menu

The digital connection is activated as soon as the device is switched on as the wireless system is designed to use very little electricity. A mobile device can link up to the active measuring device via an app.

Application (app)

An app is required to use the digital connection You can download the app from the corresponding stores for the specific type of terminal device:
App store
Google play

Make sure that the wireless interface of the mobile device is activated.

After starting the app and activating the digital connection, a connection can be set up between a mobile device and the measuring device.If the app detects several active measuring devices, select the matching device. This measuring device can be connected automatically the next time it is switched on.

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

Calibration

The measuring device must be calibrated and tested on a regular basis to ensure it is accurate and working properly. We recommend carrying out calibration once a year. Contact your distributor or the UMAREX-LASERLINER service department.

Error code:

204: Calculation error
208: Overcurrent
220: Replace the battery
255: Received signal too weak
256: Received signal too strong
261: Outside the measuring range
500: Hardware fault

Technical Data

(Subject to technical changes without notice. 21W48)

Precision (typical)* ± 1.5 mm
Measurement range (inside)** 0.2 m – 150 m
Laser wavelength 635 nm
Laser class 2 / < 1 mW (EN 60825-1:2014/AC:2017)
Units m / ft / inch / ‘‘
Memory 50 storage locations
Connections USB type C
Power supply 3 x 1.2V HR03 (AAA) NiMH
Operating conditions -10°C…40°C, Max. humidity 20…85% rH,no condensation,

Max. working altitude 2000 m above sea level
Storage conditions| -20°C…70°C, Max. humidity 80% rH
Automatic switch-off| 30 sec laser / 3 min device
Dimensions (W x H x D)| 54 x 130 x 28 mm
Weight| 184 g (incl. batteries)

measuring distance up to 10 m with strongly reflective target surface and at room temperature. The measurement deviation may increase by ± 0.2 mm/m for greater distances and under unfavourable measuring conditions such as strong sunlight or weakly reflective target surfaces.
at max. 15,000 lux

EU directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU.

This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.

Further safety and supplementary notices at: https://packd.li/ll/akk/in

SERVICE

Umarex GmbH & Co. KG
– Laserliner – Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: +49 2932 638-333
[email protected]

Umarex GmbH & Co. KG Donnerfeld 2 59757 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: +49 2932 638-333
www.laserliner.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals