Dextra Rubix Suspended Installation Installation Guide
- June 9, 2024
- Dextra
Table of Contents
Rubix Suspended Installation
Installation Guide
Rubix Suspended Installation
WARNING: Luminaire must be earthed. Risk of electric shock from LED
boards if operated with cover removed. Installation / operation outside of
luminaires intended scope invalidates warranty. Suitable only for domestic /
light industrial / industrial applications within the scope of EN55015. Tested
to compliance with BSEN 60598: specification for general requirements and
tests. Must be installed by a suitably qualified person in accordance with all
relevant legislation. Ambient operating temperature of 0°C to 25°C. If maximum
operating temperature is exceeded luminaire will automatically dim / switch
off. Terminal blocks are rated to 16A unless stated otherwise. The light
source contained in this luminaire shall only be replaced by the manufacturer
or his service agent or a similar qualified person.
LUMINAIRES WITH EMERGENCY PACK: When supply is isolated battery output
terminals may be live if battery is connected. Isolate mains and battery
before servicing. Emergency luminaires require unswitched live connection
taken from same phase as switched supply. When unswitched supply is connected
status indicator illuminates green, when unswitched supply is disconnected
indicator extinguishes and luminaire operates in emergency mode. 24 hour
charge period required before undertaking full discharge test. Emergency test
sheets provided should be used to record all emergency tests. Batteries should
be replaced when 3 hour duration is not met. Excessive switching of permanent
live may result in premature battery failure. Battery electrolyte can be
harmful to eyes / open wounds, do not puncture, if electrolyte touches skin /
eyes flush with water. Do not incinerate batteries.
1. Firstly check fitting type is correct before installation – through-wire
versions have cable cut-outs in ends and threaded holes for joining bracket /
end plate| 2. Luminaire comes in 3 length options – all require suspension
points at 1200mm
---|---
|
3. When mounting continuously, STARTER should have x2 suspensions. Subsequent
TW fittings require just one…
If preferred, each fitting CAN have 2 suspensions fitted (at same centres as
STARTER). NOTE, if custom infill pieces are specified, positions of
suspensions will be different – always check before installation!!| 4. Secure
suspension drops as shown in marked positions.
Screw suspension wire and clutch into ceiling fixture.
|
5. Insert toggles of Y suspension kit in to 7mm holes in luminaire
To attach to main wire, depress top of clutch & insert wire| 6. To make
electrical connection, loosen thumbnut, remove / lift away cover plate. Pass
cable through entry gland and connect to appropriate terminations
|
7. Fittngs are supplied with joining brackets reversed (1) – ensure both
screws are removed / brackets rotated / re-fixed ready to connect to next
fitting (2)| 8. When mounting continuously, fit joining brackets as
shown using x2 M4x10 screws in the slots.
|
9. Bend tab down 90 degrees as shown| 10. Slide the joining bracket to one
side and drop the throughwire loom into the next fitting.
The through wire cable should be connected and located as shown (6-core as
standard).
|
11. Once through-wire loom is connected, slide the joining bracket across to
cover the loom and secure with remaining x2 M4x10 screws as shown.| 12. At
Start and End of runs, fit ER cap (use x2 M4x10 screws (supplied)
|
13. Corner Installation
To install a corner section, first install the luminaires each sideof the
corner.
NOTE: A suspension point must be installed on both luminaires either side
of the corner.| 14. Measure 185mm from the previous suspension drop and mark.
Then, at the required angle, measure a further 185mm and install the next
suspension
drop.
|
15. The luminaires can be installed on the suspension drops.
Using the joining brackets provided, secure the corner between the luminaires
and connect the internal wiring loom as per steps 8-11 above.| 16. The corner
covers are secured using a single screw in the rear.
Ensure the earth leads are connected inside the corners.
|
Maintenance
- Disconnect luminaire before undertaking any maintenance or cleaning.
- Cleaning should be undertaken on external parts of the luminaire only using a slightly damp lint free cloth.
- In an anticlockwise motion turn thumbnuts to release end plates.
- Using a pan pozi screwdriver to remove gear cover. Gear tray willnow be removable.
- Use a pan pozi screwdriver to remove components.
- Please contact Dextra for assistance with spare component supply.
Power
L1| Switched Live
E **| Earth
N| Neutral
Emergency
L2| Unswitched Live
DA/AT3| DALI Autotest
A/AT3| DALI Autotest
Dimming**
-/D1/DA| Analogue/DSI/DALI
+/D2/DA| Analogue/DSI/DALI
L3| Switch Dim /Corridor Function