TELTONIKA FMC130 Advanced LTE Terminal User Guide
- June 9, 2024
- teltonika
Table of Contents
- TELTONIKA FMC130 Advanced LTE Terminal
- FMC130 Advanced LTE Terminal
- Product Usage
- Know your device
- Pinout
- Wiring scheme
- Set up your device
- PC Connection (Windows)
- How to install USB drivers (Windows)
- Configuration (Windows)
- Quick SMS configuration
- Mounting recommendations
- LED indications
- Characteristics
- Safety information
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TELTONIKA FMC130 Advanced LTE Terminal
FMC130 Advanced LTE Terminal
Product Information
The FMC130 is an advanced LTE terminal that allows for flexible inputs configuration. It has a 2×6 socket pinout with various pins for power supply, digital and analog inputs/outputs. The device also supports Micro-SIM card and battery connection.
Pinout Table
PIN NUMBER | PIN NAME | DESCRIPTION |
---|---|---|
1 | VCC (10-30) V DC (+) | Power supply (10-30 V DC). |
2 | DOUT 3 | Digital output, channel 3. Open collector output. Max. 0,5 A |
DC.
3| DIN 3 / AIN 2| Analog input, channel 2. Input range: 0-30 V DC / Digital
input, channel 3.
4| DIN 2-N / AIN 1| Digital input, channel 2, Negative input (ground sense),
Analog
input, channel 1, Input range: 0-30 VDC.
5| DIN 1| Digital input, channel 1.
6| INPUT 6| Not specified.
7| GND (-)| Ground connection.
8| DOUT 1| Digital output, channel 1. Open collector output. Max. 0,5 A
DC.
9| DOUT 2| Digital output, channel 2. Open collector output. Max. 0,5 A
DC.
10| 1WIRE POWER| Not specified.
11| 1WIRE DATA| Not specified.
12| INPUT 5| Not specified.
Product Usage
Micro-SIM and Battery Connection
- Gently remove FMC130 bottom cover using plastic pry tool from both sides. Then remove the top cover.
- Insert Micro-SIM card with PIN request disabled. Make sure that Micro-SIM card cut-off corner is pointing forward to slot.
- Connect battery to the device. Position the battery in place where it does not obstruct other components.
- After configuration, attach device top and bottom cover back.
PC Connection (Windows)
- Download COM port drivers from the official website and extract them.
- Run TeltonikaCOMDriver.exe and click “Next” in driver installation window.
- In the following window click “Install” button. Setup will continue installing the driver and eventually the confirmation window will appear.
- Click “Finish” to complete the setup.
Configuration (Windows)
- Download the latest Teltonika Configurator version from the official website.
- Extract it and launch Configurator.exe.
- After launch, change software language if required by clicking in the right bottom corner.
- Perform main configuration according to the user’s needs.
Know your device
Figure 1 Device view
Pinout
Table 1 FMC130 2×6 socket pinout
PIN NUMBER | PIN NAME | DESCRIPTION |
---|---|---|
1 | VCC (10-30) V DC (+) | Power supply (10-30 V DC). |
2 | DOUT 3 | Digital output, channel 3. Open collector output. Max. 0,5 A DC. |
3 | DIN 3 / AIN 2 | Analog input, channel 2. Input range: 0-30 V DC / Digital |
input, channel 3.
4
|
DIN 2-N / AIN 1
| Digital input, channel 2, Negative input (ground sense), Analog input,
channel 1, Input range: 0-30 VDC.
5| DIN 1| Digital input, channel 1.
6| INPUT 6| TX EXT (LVCAN – TX).
7| GND (-)| Ground pin. (10-30) V DC (―)
8| DOUT 1| Digital output, channel 1. Open collector output. Max. 0,5 A DC.
9| DOUT 2| Digital output, channel 2. Open collector output. Max. 0,5 A DC.
10| 1WIRE POWER| +3,8 V output for 1–Wire devices.
11| 1WIRE DATA| Data for 1–Wire devices.
12| INPUT 5| RX EXT (LVCAN – RX).
Figure 2 device 2×6 socket pinout
Wiring scheme
Figure 3 Wiring scheme
Set up your device
How to insert Micro-SIM card and connect the battery
- Gently remove FMC130 bottom cover using plastic pry tool from both sides. Then remove the top cover.
- Insert Micro-SIM card as shown with PIN request disabled or read our Wiki how to enter it later in Teltonika Configurator. Make sure that Micro-SIM card cut-off corner is pointing forward to slot.
- Connect battery as shown to device. Position the battery in place where it does not obstruct other components.
- After configuration, see “PC Connection (Windows)”, attach device top and bottom cover back.
Figure 4 Covers removal
Figure 5 Micro-SIM card insert
Figure 6 Battery connection
Figure 7 Cover removal
PC Connection (Windows)
- Power-up FMC130 with DC voltage (10 – 30 V) power supply using supplied power cable. LED’s should start blinking, see “LED indications”.
- Connect device to computer using Micro-USB cable or Bluetooth connection:
- Using Micro-USB cable
- You will need to install USB drivers, see “How to install USB drivers (Windows)”
- Using Bluetooth
- FMC130 Bluetooth is enabled by default. Turn on Bluetooth on your PC, then select Add Bluetooth or other device > Bluetooth. Choose your device named – “FMCxxx_last_7_imei_digits”, without LE in the end. Enter default password 5555, press Connect and then select Done.
- You are now ready to use the device on your computer.
How to install USB drivers (Windows)
- Please download COM port drivers from here.
- Extract and run TeltonikaCOMDriver.exe.
- Click Next in driver installation window.
- In the following window click Install button.
Setup will continue installing the driver and eventually the confirmation window will appear. Click Finish to complete the setup.
Configuration (Windows)
At first FMC130 device will have default factory settings set. These settings
should be changed according to the user’s needs. Main configuration can be
performed via Teltonika Configurator software. Get the latest Configurator
version from here. Configurator operates on Microsoft Windows OS and uses
prerequisite MS .NET Framework. Make sure you have the correct version
installed.
Table 2 MS .NET requirements
MS .NET REQUIREMENTS
Operating system | MS .NET Framework version | Version | Links |
---|
Windows Vista Windows 7
Windows 8.1
Windows 10| MS .NET Framework 4.6.2| 32 and 64 bit|
www.microsoft.com
Downloaded Configurator will be in compressed archive. Extract it and launch Configurator.exe. After launch software language can be changed by clicking i n the right bottom corner (Figure 8 Language selection).
Figure 8 Language selection
Configuration process begins by pressing on connected device (Figure 9 Device connected via USB).
Figure 9 Device connected via USB
After connection to Configurator Status window will be displayed (Figure 10 Configurator Status window).
Figure 10 Configurator Status window
Various Status window tabs display information about GNSS, GSM, I/O, Maintenance and etc. FMC130 has one user editable profile, which can be loaded and saved to the device. After any modification of configuration, the changes need to be saved to device using Save to device button. Main buttons offer following functionality:
- Load from device – loads configuration from device.
- Save to device – saves configuration to device.
- Load from file – loads configuration from file.
- Save to file – saves configuration to file.
- Update firmware – updates firmware on device.
- Read records – reads records from the device.
- Reboot device – restarts device.
- Reset configuration – sets device configuration to default.
Most important configurator section is GPRS – where all your server and GPRS
settings can be configured and Data Acquisition – where data acquiring
parameters can be configured.
More details about FMC130 configuration using Configurator can be found in our
Wiki.
Quick SMS configuration
Default configuration has optimal parameters present to ensure best
performance of track quality and data usage.
Quickly set up your device by sending this SMS command to it:
Note : Before SMS text, two space symbols should be inserted.
GPRS settings:
- 2001 – APN
- 2002 – APN username (if there are no APN username, empty field should be left)
- 2003 – APN password (if there are no APN password, empty field should be left)
Server settings:
- 2004 – Domain
- 2005 – Port
- 2006 – Data sending protocol (0 – TCP, 1 – UDP)
Default configuration settings
Movement and ignition detection:
- Vehicle movement will be detected by accelerometer
- Ignition will be detected by vehicle power voltage between 13,2 – 30 V
Device makes a record On Moving if one of these events happen:
- 300 seconds passes
- Vehicle turns 10 degrees
- Vehicle drives 100 meters
- Speed difference between last coordinate and current position is greater than 10 km/h
Device makes a record On Stop if:
- 1 hour passes while vehicle is stationary and ignition is off
Records sending to server:
- If device has made a record it is sent to the server every 120 seconds
After successful SMS configuration, FMC130 device will synchronize time and update records to configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator or SMS parameters.
Mounting recommendations
- Connecting wires
- Wires should be connected while the module is not plugged in.
- Wires should be fastened to stable wires or other non-moving parts. Any heat emitting and/or moving objects should be kept away from the wires.
- There should be no exposed wires. If factory isolation was removed while connecting the wires, the isolation material should be applied.
- If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied and the wires should not be loose.
- Wires cannot be connected to the board computers or control units.
- Connecting power source
- Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on the car model, this may happen in 5 to 30 minutes period.
- When the module is connected, measure the voltage again to make sure it did not decrease.
- It is recommended to connect to the main power cable in the fuse box.
- 3 A, 125 V external fuse shall be used.
- Connecting ignition wire
- Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
- Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
- Check if power is still available when you turn off any of vehicles devices.
- Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen.
- Connecting ground wire
- Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
- If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
- For better contact scrub paint from the spot where loop is going to be connected.
LED indications
Table 3 Navigation LED indications
BEHAVIOUR | MEANING |
---|---|
Permanently switched on | GNSS signal is not received |
Blinking every second | Normal mode, GNSS is working |
Off | GNSS is turned off because: |
Device is not working or Device is in sleep mode
Blinking fast constantly| Device firmware is being flashed
Table 4 Status LED indications
BEHAVIOUR | MEANING |
---|---|
Blinking every second | Normal mode |
Blinking every two seconds | Sleep mode |
Blinking fast for a short time | Modem activity |
Off | Device is not working or Device is in boot mode |
Characteristics
Basic characteristics
Table 5 Basic characteristics
MODULE|
---|---
Name
| MeiG SLM320-E, MeiG SLM320-LA, Quectel EC21-
EC, Quectel EC21-AU, Quectel EC21-J, Quectel EC21-KL, Teltonika TM2500
Technology| LTE(CaT1)/3G(UMTS/HSPA)/2G(GSM/GPRS)/GNSS/B LUETOOTH
GNSS|
GNSS| GPS, GLONASS, GALILEO, BEIDOU, QZSS, AGPS
Receiver| Tracking: 33
Tracking sensitivity| -165 dBm
Accuracy| < 3 m
Hot start| < 1 s
Warm start| < 25 s
Cold start| < 35 s
CELLULAR|
Technology| LTE Cat 1, UMTS, GSM
2G bands (SLM320)
| FMC130-ME1: GSM: B2/B3/B5/B8 FMC130-ME3: GSM: B2/B3/B5/B8 FMC130-ML1: GSM:
B2/B3/B5/B8
2G bands (EC21)| EC21-EC: GSM: B3/B8
EC21-AU: GSM: B2/B3/B5/B8
---|---
3G bands (EC21)| EC21-EC: WCDMA: B1/B8
EC21-AU: WCDMA: B1/B2/B5/B8
4G bands (SLM320)| FMC130-ME1: LTE FDD: B1/B3/B5/B7/B8/B20 LTE-TDD:B38/B40/B41
FMC130-ME3: LTE FDD: B1/B3/B7/B8/B20/B28 LTE-TDD:B38/B40/B41
FMC130-ML1: LTE FDD: B1/B2/B3/B4/B5/B7/B8/B20/B28
LTE-TDD:B40
4G bands (EC21)| EC21-EC: LTE FDD: B1/B3/B7/B8/B20/B28A EC21-AU: LTE FDD:
B1/B2/B3/B4/B5/B7/B8/B28/ LTE TDD: B40
EC21-J: LTE FDD: B1/B3/B8/B18/B19/B26
EC21-KL: LTE FDD: B1/B3/B8/B18/B19/B26
Data transfer (SLM320)| LTE: LTE FDD: Max 10Mbps (DL)/Max 5Mbps (UL)
LTE TDD: Max 8Mbps (DL)/Max 2Mbps (UL)
GSM: GPRS: Max 85.6Kbps (DL)/Max 85.6Kbps (UL)
Data transfer (EC21)| LTE: LTE FDD: Max 10Mbps (DL)/Max 5Mbps (UL) LTE TDD:
Max 8.96Mbps (DL)/Max 3.1Mbps (UL)
UMTS: WCDMA: Max 384Kbps (DL)/Max 384Kbps (UL)
GSM: GPRS: Max 107Kbps (DL)/Max 85.6Kbps (UL)
Transmit power| Class 4 for GSM850/900: 23±2dBm Class 1 for
GSM1800/1900: 20±2dBm Class 3 for LTE-TDD: 23±2.7dBm
Class 3 for LTE-FDD: 23±2.7dBm
POWER
Input voltage range | 10-30 V DC with overvoltage protection |
---|---|
Back-up battery | 170 mAh Li-Ion battery 3.7 V (0.63 Wh) |
Internal fuse | 3 A, 125 V |
Power consumption | At 12V < 3 mA [(Ultra Deep |
Sleep](https://wiki.teltonika.lt/index.php?title=FMC130_Sleep_modes&Ultra_Deep_Sleep_mode))
At 12V < 5 mA (Deep
Sleep)
At 12V < 16 mA (Online Deep
Sleep)
At 12V < 18 mA (GPS
Sleep)
At 12V < 33 mA (nominal with no load)
At 12V < 2A Max. (with full Load / Peak)
BLUETOOTH
Specification | 4.0 + LE |
---|---|
Supported peripherals | [Temperature and Humidity sensor,](https://teltonika- |
gps.com/product/bluetooth-sensor/) OBDII dongle, Inateck Barcode Scanner, Universal BLE sensors support
PHYSICAL SPECIFICATION
Dimensions | 65 x 56 x 20,6 mm (L x W x H) |
---|---|
Weight | 55 g |
INTERFACE
Digital Inputs | 3 |
---|---|
Negative Inputs | 1 (Digital Input 2) |
Impulse Inputs | 2 (Digital Input 1, Digital Input 2) |
Digital Outputs | 3 |
Analog Inputs | 2 |
CAN Adapter inputs | 1 |
--- | --- |
1-Wire | 1 |
GNSS antenna | Internal High Gain |
Cellular antenna | Internal LTE High Gain |
USB | 2.0 Micro-USB |
LED indication | 2 status LED lights |
SIM | Micro-SIM + eSIM |
Memory | 128MB internal flash memory |
OPERATING ENVIRONMENT
Operating temperature (without battery)| -20 °C to +85 °C
Storage temperature (without battery)| -20 °C to +85 °C
Operating temperature (with battery)| -20 °C to +40 °C
Storage temperature (with battery)| -20 °C to +45 °C
Operating humidity| 5% to 95% non-condensing
Ingress Protection Rating| IP41
Battery charge temperature| 0 °C to +45 °C
Battery discharge temperature| -20 °C to +60 °C
Battery storage temperature
| -20 °C to +45 °C for 1 month
-20 °C to +35 °C for 6 months
FEATURES
Sensors| Accelerometer
---|---
Scenarios
| Green
Driving,
Over Speeding
detection,
GNSS
Fuel
Counter,
DOUT Control Via
Call,
Excessive
Idling
detection,
Immobilizer,
iButton
Read
Notification,
Unplug
detection,
Towing
detection,
Crash
detection,
Auto
Geofence,
Manual
Geofence,
Trip
,Ground
Sense
Sleep modes| GPS
Sleep,
Online Deep
Sleep,
Deep
Sleep,
Ultra
Deep
Sleep
Configuration and firmware update| FOTA
Web,
FOTA, Teltonika
Configurator (USB,
Bluetooth),
SMS| Configuration, Events, DOUT control, Debug
GPRS commands| Configuration, DOUT control, Debug
Time Synchronization| GPS, NITZ, NTP
Fuel monitoring| LLS (Analog), LV-CAN200, ALL-CAN300,
OBDII
dongle
, CAN-CONTROL, OBDII
dongle
Ignition detection| Digital Input 1, Accelerometer, External Power Voltage,
Engine RPM (CAN Adapters, OBDII dongle)
Electrical characteristics
Table 6 Electrical characteristics
| CHARACTERISTIC DESCRIPTION| VALUE
---|---|---
| MIN.| TYP.| MAX.| UNIT
| SUPPLY VOLTAGE
| Supply Voltage (Recommended Operating Conditions)| +10| | +30| V
| DIGITAL OUTPUT (OPEN DRAIN GRADE)
| Drain current (Digital Output OFF)| | | 120| µA
| Drain current (Digital Output ON, Recommended Operating Conditions)| | 0.1|
0.5| A
| Static Drain-Source resistance (Digital Output ON)| | 400| 600| mΩ
| DIGITAL INPUT
| Input resistance (DIN1)| 47| | | kΩ
| Input resistance (DIN2)| 38.45| | | kΩ
| Input resistance (DIN3)| 150| | | kΩ
| Input voltage (Recommended Operating Conditions)| 0| | Supply voltage| V
| Input Voltage threshold (DIN1)| | 7.5| | V
| Input Voltage threshold (DIN2)| | 2.5| | V
| Input Voltage threshold (DIN3)| | 2.5| | V
ANALOG INPUT|
Input voltage (Recommended Operating Conditions), Range 1| 0| | +10| V|
Input resistance, Range 1| | 38.45| | kΩ|
Measurement error on 12V, Range 1| | 0.9| | %|
Additional error on 12 V, Range 1| | 108| | mV|
Measurement error on 30 V, Range 1| | 0.33| | %|
Additional error on 30 V, Range 1| | 88| | mV|
Input Voltage (Recommended Operating
Conditions), Range 2
| 0| | +30| V|
Input resistance, Range 2| | 150| | kΩ|
Measurement error on 12 V, Range 2| | 0.9| | %|
Additional error on 12 V, Range 2| | 108| | mV|
Measurement error on 30 V, Range 2| | 0.33| | %|
Additional error on 30 V, Range 2| | 88| | mV|
OUTPUT SUPPLY VOLTAGE 1-WIRE|
Supply voltage| +4.5| | +4.7| V|
Output inner resistance| | 7| | Ω|
Output current (Uout > 3.0 V)| | 30| | mA|
Short circuit current (Uout = 0)| | 75| | mA|
NEGATIVE INPUT|
Input resistance| 38.45| | | kΩ|
Input voltage (Recommended Operating Conditions)| 0| | Supply voltage| V|
Input voltage threshold| | 0.5| | V|
Sink current| | | 180| nA|
Safety information
This message contains information on how to operate FMC130 safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!
- The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed voltage range is +10..+30 V DC.
- To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible. They show the status of device operation.
- When connecting the 2×6 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.
- Before unmounting the device from the vehicle, the 2×6 connector must be disconnected. The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 62368-1 standard. The device FMC130 is not designed as a navigational device for boats.
- Do not disassemble the device. If the device is damaged, the power supply cables are not isolated or the isolation is damaged, DO NOT touch the device before unplugging the power supply.
- All wireless data transferring devices produce interference that may affect other devices which are placed nearby.
- The device must be connected only by qualified personnel.
- The device must be firmly fastened in a predefined location.
- The programming must be performed using a PC with autonomic power supply.
- Installation and/or handling during a lightning storm is prohibited.
- The device is susceptible to water and humidity.
- Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
- Battery should not be disposed of with general household waste. Bring damaged or worn-out batteries to your local recycling center or dispose them to battery recycle bin found in stores.
Warranty
TELTONIKA guarantees its products to be free of any manufacturing defects for
a period of 24 months. With additional agreement we can agree on a different
warranty period, for more detailed information please contact our sales
manager.
Contact us teltonika-gps.com/about-us/contacts/
All batteries carry a reduced 6 month warranty period.
If a product should fail within this specific warranty time, the product can
be:
- Repaired
- Replaced with a new product
- Replaced with an equivalent repaired product fulfilling the same functionality
- TELTONIKA can also repair products that are out of warranty at an agreed cost.
Warranty Disclaimer
TELTONIKA PRODUCTS ARE INTENDED TO BE USED BY PERSONS WITH TRAINING AND
EXPERIENCE. ANY OTHER USE RENDERS THE LIMITED WARRANTIES EXPRESSED HEREIN AND
ALL IMPLIED WARRANTIES NULL AND VOID AND SAME ARE HEREBY EXCLUDED. ALSO
EXCLUDED FROM THIS LIMITED WARRANTY ARE ANY AND ALL INCIDENTAL OR
CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO, LOSS OF USE OR REVENUE,
LOSS OF TIME, INCONVENIENCE OR ANY OTHER ECONOMIC LOSS.
More information can be found at teltonika-gps.com/warranty-repair/
References
- Teltonika Telematics
- Your request has been blocked. This could be due to several reasons.
- Teltonika Telematics
- Teltonika Telematics
- Expand The Usage Of GPS Trackers With Handy Our Accessories
- LV-CAN200 - CAN Adapter For Reading CAN Bus Data
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- Teltonika | Wiki Knowledge Base
- FMC130 Negative Input Usage Scenario - Wiki Knowledge Base | Teltonika GPS
- wiki.teltonika.lt/view/FMC130_Parameter_list
- wiki.teltonika.lt/view/FMC130_Status_info
- wiki.teltonika.lt/view/FMC130_Status_info#GNSS_Info
- wiki.teltonika.lt/view/FMC130_Status_info#GSM_Info
- wiki.teltonika.lt/view/FMC130_Status_info#I.2FO_Info
- wiki.teltonika.lt/view/FMC130_Status_info#Maintenance
- FOTA WEB - Wiki Knowledge Base | Teltonika GPS
- How to connect OBD II Bluetooth Dongle to FMB device - Wiki Knowledge Base | Teltonika GPS
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>