Anolis Calumma XS MC LED Lighting User Manual

June 9, 2024
ANOLiS

Anolis Calumma XS MC LED Lighting

Anolis Calumma XS MC LED Lighting

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR Calumma ! Save it for future reference.

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.

The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device.

Unauthorized modification will void warranty.

Safety instructions

DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!

Always disconnect the fixture from power before cleaning, servicing or installing.
This fixture should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied, consult your authorized distributor or local power company.

Always disconnect the fixture from AC power before servicing or cleaning.
Make sure the power/data cable is not damaged by sharp edges.
Do not install the unit near an open flame.
Refer servicing to qualified service personnel.
Do not connect this fixture to a dimmer pack.

LED light emission. Risk of eye injury. Do not look into the beam from a short distance without suitable protective eyewear. Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the light output.

The fixture was designed for outdoor use. This fixture must not be used for underwater installation.  When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials when the fixture is under operation. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened. The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance. Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons not qualified to operate the fixture. Most damages are the result of unprofessional operation!

Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity.
The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m. The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g. transmitters in surrounding area) before installing the equipment. Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B. Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!

Please use the original packaging if the fixture is to be transported. If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric shock etc.

Fixture exterior view

  1. Transparent glass cover
  2. Mounting yoke
  3. Tilt adjusting lock
  4. LED module with heat sink
    Fixture exterior view

Control and connection

The Eminere Remote modules should be connected to the E-Box Remote or E-Box Remote basic via junction boxes.

The E-box Remote has to be switched to the Pass-Through mode.

Example of connection with E-box Remote

Control and connection

Example of connection with E-box Remote Basic

Example of connection with E-box Remote Basic

Note. Combination of Calummas XS and Emineres is also possible.
Example:

Control and connection

The table below states max. number of Calumma XS modules connected to the E-box Remote/E-box Remote Basic.

Cable length * Calumma XS
25 m 32
50 m 32
75 m 26
100 m 20
  • Cable length is a total cable length between E-box Remote (E-box Remote Basic) and last connected Eminere Remote.
    Example: Total cable length=L1+L2+L3+L4+L5+L6+L7+L8+L9

Control and connection

Max. number of Calumma XS modules connected to the one output of the E-box Remote/E box Remote Basic is 32.

Installation

Mounting the fixture

The Calumma can be fastened in any orientation on a flat, non-flammable surface by means of mounting yoke (2).

Mounting the fixture

The LED module (4) can be tilted +180°/-180°. Use an Allen key 2.5 for adjusting a LED module position.

Ensure that the structure to which you are attaching the fixture is secure.

Connection to power

The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.

Junction box installation

Junction box with one output

Junction box installation

  1. .Unscrew the four screws (1) from the cover (2) on the junction box to get access to the DPS with terminal blocks (3) and two mounting holes (4).
  2.  Screw the junction box on a non-flammable flat surface.
  3. Connect cables to terminal blocks.
    Two cable glands M20 x 1.5 serves for a power/data cable. One (or four) cable gland M12 x 1.5 serves for Calumma XS connection cable.
    Remove the end cap from the cable gland before passing the cable. We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body.

Cable gland M20x1.5 and M12x1.5

Cable gland M20x1.5 and M12x1.5

Wiring of connection blocks on DPS RB4232 in the junction box with one LED output.

Fuse F1: 2A/500V AC.

Connection to power

Wiring of connection blocks on DPS RB4233 in the junction box with four LED outputs.

Fuse F1-F4: 2A/500V AC.

Connection to power

Calumma XS connection:

Connector| Vcc| D+| D-| 0V|
---|---|---|---|---|---
Function| LEDs +| Data +| Data –| LEDs –| Not connected
Colour of wire| Red| Orange| White| Black|

Colours of wires apply to the 5-cored cable UL 20969 5x 20AWG (P/N 13053481)

Connection between junction box and E-box Remote and among junction boxes:

Connector| Vcc| D+| D-| 0V|
---|---|---|---|---|---
Function| LEDs +| Data +| Data –| LEDs –| Not connected
Colour of wire| Red| Orange| White| Black|

Colours of wires apply to the 5-cored cable SJTW 5x 14AWG (P/N 1305 3336).

NOTE: Each line of Calummas XS connected to the LED output of the E-box Remote has to be terminated at the last fixture.

EITHER connect a 120 Ohm resistor between terminals D+ and D- in the last fixture,
OR terminate via RDM as described in the E-box Remote user manual.

Ensure ONLY the last fixture in the line is terminated using ONE of the above methods!

Examples
Termination via 120 Ohm resistor

Termination via 120 Ohm resistor

Termination via RDM:
Termination via RDM

  1. Screw the cover (2) back on the junction box.

Software update

Software update of Calumma module has to be done by means of the software ROBE Uploader running on PC. The ROBE Uploader is a software for automatized software update of ROBE fixtures. The ROBE Uploader switches Calummas to the update mode automatically.
Please see https://www.robe.cz/robe-uploader/ for more information.

Note: Calumma modules in DALI connection and ON/OFF connection cannot be updated.

DMX or Ethernet connection via E-box

  1. By means of DMX connection and RUNIT.
    DMX or Ethernet connection via E-box 

  2. By means of the Ethernet connection
    Software update

If the option Pass-Through is selected from the menu E-box Remote mode, the E-box will not be updated, only connected Calumma modules. You have to use the file Calumma.lib in the ROBE Uploader for this operating mode.

If the option Standard is selected from the menu E-box Remote mode, the E-box will be updated including connected Calumma modules. You have to use the file EminereEbox.lib in the ROBE Uploader for this operating mode.

The Calummas XS should be operated in the Pass-Through mode only.
If you need to update connected E-box Remote, switch the E-box Remote to the Standard mode and use the EminereEbox.lib in the ROBE Uploader to update E-box Remote. After updating the E-box Remote, switch it back to the Pass-Trough mode.

Technical specifications

Power supply

  • Input voltage: 48 V
  • Power consumption:
    Calumma XS MC: 10 W
    Calumma XS SC: 10 W

Optic

  • Light source:
    Calumma XS MC: one high power multichip LEDs
    Calumma XS SC: 4 x high power single chip LED

  • Colour variants Calumma XS MC: RGBW (W – 6500 K), RGBA, PW (W – 3000 K)

  • Colour variants Calumma XS SC: PW (W – 3000 K)

  • Beam Angle Calumma XS MC:
    Symetrical: 9°, 15°, 25°, 30°, 45°, 65°, 100°
    Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 15° x 45°, 45° x 15°, 15°x90°, 90°x15°, 30°x60°, 60°x30°, 30°x90°, 90°x30°

  • Beam Angle Calumma XS SC:
    Symetrical: 10°, 15°, 25°, 30°, 45°, 65°, 100°
    Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 15° x 45°, 45° x 15°, 15°x90°, 90°x15°, 30°x60°, 60°x30°, 30°x90°, 90°x30°

  • Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F

Compatible drivers

  • E-box Remote
  • E-box Remote Basic

Mounting method

  • Via yoke
  • Adjustability: -180°/+180°

Housing

  • High pressure die-cast aluminium body
  • Tempered glass

Cooling system

  • Convection

Total heat dissipation

  • Calumma XS MC: 25 BTU/h (calculated)
  • Calumma XS SC: 25 BTU/h (calculated)

Protection factor

  • CE: IP 67 (IP 66 junction box)
  • US: Suitable for wet location

Impact rating

  • IK10

Operating ambient temperature range

  • -20°C /+40°C (-4°F /+104°F)

Connection

  • Via E-box Remote/E-box Remote Basic
    Calumma IN: cable UL 20969 5x 20AWG (P/N 13053481), length 1m standard
    Interconnecting cable between junction boxes: SJTW 5x 14AWG (P/N 13053336)
    Junction Box for Calumma XS, (1x Output)
    Junction Box for Calumma XS, (4x Output)

Weight

  • Calumma XS MC: 0.59 kg (1.3 lbs)
  • Calumma XS MC: 0.6 kg (1.3 lbs)

Dimensions (All dimensions in mm [inch])

Dimensions

Junction box with one output

Junction box with one output

Junction box with four outputs

Junction box with four outputs

Included items

  • 1 x Calumma XS MC / Calumma XS SC
  • 1 x User manual

Optional accessories

Top Hat Calumma XS RAL9011 (P/N 10980732)
Half Top Hat Calumma XS RAL9011 (P/N 10980736)
Tenon Adaptor for Calumma XS
Pole Mount Bracket for Calumma XS
Junction Box for Calumma XS, 1x Output, Ral 9011 (P/N 10980715)
Junction Box for Calumma XS, 4x Output, Ral 9011 (P/N 10980716)

Cleaning and maintenance

DANGER !
Disconnect from the mains before starting any maintenance or cleaning work 

Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it.
Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use ROBE OEM parts.

Disposing of the product

To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes.

ChangeLog

This section summarizes changes in the user manual.

Version of manual Date of issue Description of changes
1.1 13/09/2022 Junction box connection change

Specifications are subject to change without notice.
September 14, 2022
Copyright © 2021-2022 Robe Lighting – All rights reserved
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici

Anolis Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals